20 241-250 21 251-260 22 261-270 23 271-280 24 281-290 25 291-300 26 301-310 27 Pivoted and Rigidly Guided Head Trunnion 1.00 Stop Tubes are used for reducing piston and bearing loads on to prevent buckling and jack-knifing of horizontally installed long push stroke cylinders when the piston rod is fully extended.
435 760 1370 27 55 115 240 430 760 1370 4 4 6 10 14 22 30 4 4 6 10 14 22 30 4 4 6 10 14 22 30 6 10 16 20 25 32 40 6 10 16 20 25 32 40 6 10 16 20 25 32 40 32, 40 Double acting Normally closed Normally open Single acting 3.7 13 38 57 83 161 267 JIS Symbol Double acting Note 1) Values based on pressure of 0.5 MPa, gripping point L = 20 mm, at center of stroke.
435 760 1370 27 55 115 240 430 760 1370 4 4 6 10 14 22 30 4 4 6 10 14 22 30 4 4 6 10 14 22 30 6 10 16 20 25 32 40 6 10 16 20 25 32 40 6 10 16 20 25 32 40 32, 40 Double acting Normally closed Normally open Single acting 3.7 13 38 57 83 161 267 JIS Symbol Double acting Note 1) Values based on pressure of 0.5 MPa, gripping point L = 20 mm, at center of stroke.
MHZ2-6D/MHZA2-6D MHZ2-25D/MHZL2-25D 100 Pressure 0.7 MPa 6 Pressure 0.7 MPa 0.6 MPa Gripping force (N) Gripping force (N) Gripping force (N) 80 0.6 MPa 0.5 MPa F 4 0.5 MPa 60 0.4 MPa 0.4 MPa 0.3 MPa 40 0.3 MPa 2 0.2 MPa 0.2 MPa 20 F 0 10 20 30 0 20 40 60 80 100 Gripping point L (mm) Gripping point L (mm) External Grip MHZ2-10D/MHZL2-10D MHZ2-32D MHZA2, MHZ2, MHZL2 250 Pressure 0.7 MPa 20
Baud rate Max. bus cable length 1 Mbit/s 25 m 800 kbit/s 50 m 500 kbit/s 100 m 250 kbit/s 250 m 125 kbit/s 500 m 50 kbit/s 1000 m 20 kbit/s 2000 m 10 kbit/s 5000 m -10No.EX-OMK0006-C Bus cable and termination resistors The cables, connectors, and termination resistors used in CANopen networks shall meet the requirements defined in ISO 11898.
VXK21 VXK22 VXK23 Model 2 mm 3 mm 4.5 mm 6 mm 8 mm Orifice size Orifice size M Solenoid Coil Coil: Class B, Class H M Rated Voltage 100 VAC, 200 VAC, 110 VAC, 220 VAC, 240 VAC, 230 VAC, 48 VAC, 24 VDC, 12 VDC 1/8 1/4 1/4 3/8 1/4 3/8 Port size Normally Open (N.O.)
Table 3.1-1 Weight of the product Model Weight kg Option increase HRL100-A-40 Approx.240 Option-D1:+1kg HRL200-A-40 Approx.260 Option-T2:+1kg HRL300-A-40 Approx.330 Option-T3:+18kg* HRL100-W-40 Approx.250 HRL200-W-40 Approx.250 *Applicable only to HRL300-A*-40. 3.1 Transport HRL Series 3-2 HRX-OM-X037 Chapter 3 Transport and Setting Up 3.1.2 Transportation using casters This is a heavy product
to 249 Unused 250 to 253 Gateway unit status flag All modes 254,255 Unused 37 - Higher level device --> Gateway unit [OUT] Corresp Bit/Byte Model/ Corresponding Address Data name Value range Unit onding Size mode No.
Station n L1 L2 L1 L2 Station 2 52 43 63 54 Station 20 340 331 369 360 3 68 59 80 71 4 84 75 97 88 5 100 91 114 105 6 116 107 131 122 7 132 123 148 139 8 148 139 165 156 9 164 155 182 173 10 180 171 199 190 11 196 187 216 207 12 212 203 233 224 13 228 219 250 241 14 244 235 267 258 15 260 251 284 275 16 276 267 301 292 17 292 283 318 309 18 308 299 335 326 19 324 315 352 343 Port size M5
[ ] for AC Other dimensions are the same as the grommet. 2 52 43 63 54 3 68 59 80 71 4 84 75 97 88 5 100 91 114 105 6 116 107 131 122 7 132 123 148 139 8 148 139 165 156 9 164 155 182 173 10 180 171 199 190 11 196 187 216 207 12 212 203 233 224 13 228 219 250 241 14 244 235 267 258 15 260 251 284 275 16 276 267 301 292 17 292 283 318 309 18 308 299 335 326 19 324 315 352 343 20 340 331
Station n L1 L2 L3 L4 Station 20 341 328 304 296 3 69 56 32 24 6 117 104 80 72 8 149 136 112 104 10 181 168 144 136 Station 2 53 40 16 8 4 85 72 48 40 5 101 88 64 56 7 133 120 96 88 9 165 152 128 120 11 197 184 160 152 12 213 200 176 168 13 229 216 192 184 14 245 232 208 200 15 261 248 224 216 16 277 264 240 232 17 293 280 256 248 18 309 296 272 264 19 325 312 288 280 4-4-27 Series SYJ500
Station n L1 L2 L1 L2 Station 2 52 43 63 54 Station 20 340 331 369 360 3 68 59 80 71 4 84 75 97 88 5 100 91 114 105 6 116 107 131 122 7 132 123 148 139 8 148 139 165 156 9 164 155 182 173 10 180 171 199 190 11 196 187 216 207 12 212 203 233 224 13 228 219 250 241 14 244 235 267 258 15 260 251 284 275 16 276 267 301 292 17 292 283 318 309 18 308 299 335 326 19 324 315 352 343 Port size M5
Note 4) When the stroke is 25 mm, the maximum speed will be 250 mm/sec. Note 5) Set to the pushing force when pushing. Note 6) The speed and force may change depending on the cable length, load and mounting conditions. Furthermore, if the cable length exceeds 5 m, then it will decrease by up to 10% for each 5 m.
mA or less 5 120 mA or less 5 240 mA or less 6 120 mA or less 6 Number of outputs 8 outputs 4 outputs 8 outputs 4 outputs Output type PNP (negative common) / source Load Solenoid valve with surge voltage suppressor of 24 VDC and 1.5 W or less (manufactured by SMC) Output specification Supply current 24 VDC Residual voltage 0.3 V or less Supply current 500 mA or less 7 250 mA or less 7 240
135 140 155 134 146 162.5 20 24 24 VNC5-32F VNC6-40F VNC7-50F 100 105 120 36 42 54 12 12 14 310.5 326 350 278 293.5 317.5 VX Port size: 65F, 80F Flange connection VN VQ Applicable flange 65 80 Model H F E D C B A 1 4 1 4 405.5 441.5 65 80 140 150 204 235 175 185 305.5 341.5 210 240 VNC81 -65F VNC91 -80F 4.2-25 VNC Construction N.C.
540 4900 4300 3400 2750 240+0.45S 3.11-7 Series MXS Table Deflection Table deflection by pitch moment Table deflection by yaw moment Table deflection by roll moment Table pitch deflection due to static pitch moment applied at arrow for fully extended stroke of slide table Table yaw deflection due to static yaw moment applied at arrow for fully extended stroke of slide table.
315 385 26 + 0.2 S 745 100 70 23 30 23 25 47 35 335 340 380 450 490 655 43 + 0.2 S 1250 1400 160 105 40 53 40 45 75 60 605 610 670 735 835 1000 55 + 0.2 S 2350 2650 2900 310 130 65 120 65 80 170 115 1100 1100 1100 1200 1400 1750 166 + 0.5 S 3450 4300 4700 560 200 110 140 110 130 220 180 1750 1750 1750 1950 2400 2750 240 + 0.5 S Option Specifications Stroke Adjustment Range of Adjuster
Connect the plug of the AC cord*1 to a commercial power outlet with a ground terminal (100 to 240 VAC, 50/60 Hz). Ensure the ground terminal is correctly connected. The ground terminal is connected to the frame ground (F.G.) of this product.
Flow Rate Characteristics Aluminum Body Type Size Port size Orifice diameter [mm] Flow rate characteristics*1 Max. operating pressure differential [MPa] Model Weight*2 [g] C [dm3/(sbar)] b Cv 20 1/8, 1/4 3 1.41 0.54 0.35 0.7 JSX21-Am30m 240 5 1.66 0.54 0.52 0.2 JSX21-Am50m 240 30 1/4, 3/8 4 1.57 0.59 0.52 1.0 JSX31-Am40m 400 7 3.02 0.53 0.88 0.2 JSX31-Am70m 400 *1 The flow rate characteristics
1V 24 VAC 1K 48 VAC Conduit terminal With surge voltage suppressor Special voltage VXP VXR 1L 220 VAC 1M 240 VAC 1W 24 VAC 1P 48 VAC Conduit With surge voltage suppressor VXH VXF 1Q 220 VAC 1R 240 VAC 1Y 24 VAC VX3 VXA 2A 24 VDC 2B 100 VAC 2C 110 VAC 2D 200 VAC 2E 230 VAC 2F 48 VAC 2G 220 VAC 2H 240 VAC 2V 24 VAC 2L 100 VAC DIN terminal With surge voltage suppressor With light 2M 110 VAC