SMC Corporation of America
Elite Part Number Search
Search Results "RSQA50-25DL"

Magnet: D (Built-in), Mounting: B (Through Hole, Standard), Bore Size: 40mm, Water Resistant: None, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 25mm, Action: D (Double Acting), Rod End: L (Lever Type, Fixed Absorber Type), Direct Mount Switch Groove: None, Mounting Bolt: None, Auto Switch: A90--Reed, AC Volt, Horizontal

Magnet: Built-in, Mounting: Through Hole, Standard, Bore Size: 40mm, Water Resistant: None, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 25mm, Action: Double Acting, Rod End: Lever Type, Fixed Absorber Type, Direct Mount Switch Groove: None, Mounting Bolt: None, Auto Switch: M9N--Solid State , Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: -, Number

Magnet: Built-in, Mounting: Through Hole, Standard, Bore Size: 40mm, Water Resistant: None, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 25mm, Action: Double Acting, Rod End: Lever Type, Fixed Absorber Type, Direct Mount Switch Groove: None, Mounting Bolt: None, Auto Switch: A90--Reed, AC Volt, Horizontal, Lead Wire or Prewired Connector: -, Number: -

Magnet: Built-in, Mounting: Both Ends Tapped, Bore Size: 40mm, Water Resistant: -, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 25mm, Action: Double Acting, Rod End: Lever Type, Fixed Absorber Type, Direct Mount Switch Groove: -, Mounting Bolt: -, Auto Switch: A73--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Vertical, Lead Wire or Prewired Connector: 3m, Number: -

Magnet: Built-in, Mounting: Both Ends Tapped, Bore Size: 40mm, Water Resistant: -, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 25mm, Action: Double Acting, Rod End: Lever Type, Fixed Absorber Type, Direct Mount Switch Groove: -, Mounting Bolt: -, Auto Switch: A73--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Vertical, Lead Wire or Prewired Connector: 0.5m (Or None in the Case

Magnet: Built-in, Mounting: Both Ends Tapped, Bore Size: 40mm, Water Resistant: -, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 25mm, Action: Double Acting, Rod End: Lever Type, Fixed Absorber Type, Direct Mount Switch Groove: -, Mounting Bolt: -, Auto Switch: F7P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: -, Number: -

Magnet: Built-in, Mounting: Both Ends Tapped, Bore Size: 40mm, Water Resistant: -, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 25mm, Action: Double Acting, Rod End: Lever Type, Fixed Absorber Type, Direct Mount Switch Groove: -, Mounting Bolt: -, Auto Switch: J79--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -

Magnet: Built-in, Mounting: Both Ends Tapped, Bore Size: 50mm, Water Resistant: -, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 25mm, Action: Double Acting, Rod End: Lever Type, Fixed Absorber Type, Direct Mount Switch Groove: -, Mounting Bolt: -, Auto Switch: A73--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Vertical, Lead Wire or Prewired Connector: -, Number: -

Magnet: Built-in, Mounting: Through Hole, Standard, Bore Size: 40mm, Water Resistant: -, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 25mm, Action: Double Acting, Rod End: Lever Type, Fixed Absorber Type, Direct Mount Switch Groove: -, Mounting Bolt: -, Auto Switch: A73--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Vertical, Lead Wire or Prewired Connector: -, Number: -

Magnet: Built-in, Mounting: Through Hole, Standard, Bore Size: 40mm, Water Resistant: -, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 25mm, Action: Double Acting, Rod End: Lever Type, Fixed Absorber Type, Direct Mount Switch Groove: -, Mounting Bolt: -, Auto Switch: A73--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Vertical, Lead Wire or Prewired Connector: 3m, Number: -

Magnet: Built-in, Mounting: Through Hole, Standard, Bore Size: 40mm, Water Resistant: -, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 25mm, Action: Double Acting, Rod End: Lever Type, Fixed Absorber Type, Direct Mount Switch Groove: -, Mounting Bolt: -, Auto Switch: A76H--Reed, DC Volt.<5, LED, Horizontal, Lead Wire or Prewired Connector: -, Number: -

Magnet: Built-in, Mounting: Through Hole, Standard, Bore Size: 40mm, Water Resistant: -, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 25mm, Action: Double Acting, Rod End: Lever Type, Fixed Absorber Type, Direct Mount Switch Groove: -, Mounting Bolt: -, Auto Switch: J79W--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -

Magnet: Built-in, Mounting: Through Hole, Standard, Bore Size: 40mm, Water Resistant: -, Port Thread: Built-in One-touch Fitting, Stroke: 25mm, Action: Double Acting, Rod End: Lever Type, Fixed Absorber Type, Direct Mount Switch Groove: -, Mounting Bolt: -, Auto Switch: A73C--Reed, DC Volt.>5,<24, LED, Connector, Vertical, Lead Wire or Prewired Connector: -, Number: -

Magnet: Built-in, Mounting: Through Hole, Standard, Bore Size: 50mm, Water Resistant: -, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 25mm, Action: Double Acting, Rod End: Lever Type, Fixed Absorber Type, Direct Mount Switch Groove: -, Mounting Bolt: -, Auto Switch: A73--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Vertical, Lead Wire or Prewired Connector: -, Number: -

Magnet: Built-in, Mounting: Through Hole, Standard, Bore Size: 50mm, Water Resistant: -, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 25mm, Action: Double Acting, Rod End: Lever Type, Fixed Absorber Type, Direct Mount Switch Groove: -, Mounting Bolt: -, Auto Switch: A73--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Vertical, Lead Wire or Prewired Connector: 3m, Number: -

Magnet: Built-in, Mounting: Through Hole, Standard, Bore Size: 50mm, Water Resistant: -, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 25mm, Action: Double Acting, Rod End: Lever Type, Fixed Absorber Type, Direct Mount Switch Groove: -, Mounting Bolt: -, Auto Switch: A73--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Vertical, Lead Wire or Prewired Connector: 3m, Number: 1 pc.

Magnet: Built-in, Mounting: Through Hole, Standard, Bore Size: 50mm, Water Resistant: -, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 25mm, Action: Double Acting, Rod End: Lever Type, Fixed Absorber Type, Direct Mount Switch Groove: -, Mounting Bolt: -, Auto Switch: J79W--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: 1

Magnet: Built-in, Mounting: Both Ends Tapped, Bore Size: 40mm, Water Resistant: -, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 25mm, Action: Double Acting, Rod End: Lever Type, Fixed Absorber Type, Direct Mount Switch Groove: -, Mounting Bolt: -, Auto Switch: J79W--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: -, Number: -

Magnet: Built-in, Mounting: Through Hole, Standard, Bore Size: 50mm, Water Resistant: -, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 25mm, Action: Double Acting, Rod End: Lever Type, Fixed Absorber Type, Direct Mount Switch Groove: -, Mounting Bolt: -, Auto Switch: A73H--Reed, DC Volt.>5,<24, AC Volt.<200, LED, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -

Magnet: Built-in, Mounting: Through Hole, Standard, Bore Size: 40mm, Water Resistant: -, Port Thread: NPT, Stroke: 25mm, Action: Double Acting, Rod End: Lever Type, Fixed Absorber Type, Direct Mount Switch Groove: -, Mounting Bolt: -, Auto Switch: F7P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: -, Number: -