<br>MHF2-8D: 2.5 mm<br>MHF2-12D: 2.5 mm<br>MHF2-16D: 2.5 mm<br>MHF2-20D: 3.0 mm<br>Note 1) The operating range value is the value per finger. Double the value in relation to the workpiece diameter. <br>Note 2) This value is to be used as a guide, not a guaranteed value. <br>Note 3) The actual value may vary by up to 30% depending on the operating environment.
<br>Note) The power needs to be turned OFF and then ON again for the new settings to take effect. <br><br>
<br>The controller setting software can be downloaded here. <br>Note) The LEC-W2 USB cable (LEC-W2-U) is for use with Windows 10. <br>Applicable series: LECP6, LECA6, LECPA, and LECPMJ<br><br>
<br><br>Internal circuit and wiring example 1: NPN output type, NPN open collector 1 output, Max. applied voltage 26.4 V, Max. load current 80 mA, Residual voltage 2 V or less <br><br>Internal circuit and wiring example 2: PNP output type, PNP open collector 1 output, Max. load current 80 mA, Residual voltage 2 V or less<br><br>
<br>When the release valve is turned ON (energized), vacuum release air is generated until the valve is turned OFF (de-energized).<br>Set the energization time for each solenoid valve with a PLC or other master device.<br><br>
<br><br>
<br>After setting the pressure, be sure to lock the knob.<br>Moving the knob in the downward direction may cause the pressure to drop below the initial setting.<br>The knob rotates clockwise to increase pressure and counterclockwise to decrease pressure.<br>The setting range of the outlet pressure is 85% or less of the inlet pressure.
<br>For example, for the ITV2030 (0.5 MPa type), to set the pressure to 0.3 MPa, send (0.3 MPa/0.5 MPa) × 4095 = 2457 (DEC) = 999 (HEX) data “999” from the master PLC to the regulator.<br>Note) DEC is decimal, and HEX is hexadecimal.<br>③ ITV series CC-Link compatible products come with Bus adapters.<br>The part number of the Bus adapter is “EX9-ACY0-MJ.”
<br>As a guideline, when there is no volume, it is about 0.4 seconds.<br>For the ITV1000 and ITV2000, there is a high-speed response time type available using the special order part number suffix “-X88.”<br>For this product, as a guideline, when there is no volume (no load), it is about 0.1 second.
<br>③ If the input signal of the old IT series product was a 2-wire type current type, only 4 to 20 mADC signal wiring was required, with power supply wiring not required.<br>In this case, the ITV series regulator will need to be connected to a power supply.<br><br>The ITV1000/2000/3000 series catalog can be found https://www.smcpneumatics.com/Part-Builder-Links_ep_2458-1.html?https://smccatalog.partbuilder.smcpneumatics.com/support/faq/en-jp/?ca_id=vacuum-regulators&fa_id=11155
<br>After setting the pressure, be sure to lock the knob. Moving the knob in the downward direction may cause the pressure to drop below the initial setting. <br>The knob rotates clockwise to increase pressure and counterclockwise to decrease pressure. <br>The setting range of the outlet pressure is 85% or less of the inlet pressure.
<br>Replace each product as a whole. <br><br>The production of old AW series (2 digits: AW□□) bowl assemblies has also been terminated, and the supply is limited to whatever is left in stock. <br>Please check the part number of the bowl assembly and confirm whether it can be ordered. <br>If the current stock has run out, replace each product.
<br>The oil drains through the hole (ø6) of the drain cock, but piping cannot be connected to it.<br><br>
<br>It is recommended that the cartridge be replaced if the error occurs again even after cleaning the electrode.<br>Note) Be sure to stop supplying power when cleaning or replacing the emitter.<br><br>
ca_id=161" _blank>catalog<br><br>Note 1) You can change the electrical entry direction in 90° increments by adding XC□ to the end of the part number.<br>Note 2) In the case of a product with bracket, the end of the part number is XB□.<br>(For the applicable models, refer to the catalog.)
<br>Note) For pilot air pressure, refer to the “Specifications” section in the catalog of each series. <br>Reference) SGC and SGH series coolant valve PE ports have a filter mounted as standard.<br><br>
<br><br>Air-operated type:<br>Pilot air from an external 5-port solenoid valve is supplied to drive chambers A and B of the PA main unit via ports P1 and P2.
<br>Follow the procedure below to adjust the flow rate. <br>For the automatically operated type<br>Install a needle valve or other flow adjustment valve on the outlet side of the process pump to adjust the flow rate.
<br>Note) The water-regulating valve of HRS□-W water-cooled thermo-chillers opens and closes depending on the state of the circulating fluid. It opens and closes according to changes in the refrigerant pressure. <br>Facility water will not flow at the start of operation or when the heat load is low.<br><br>