SMC Corporation of America
Elite Part Number Search
Search Results "RLQA63-30M-F"

Vibration resistance allows for normal operation of up to 30m/s2 (45 to 250Hz). Be advised that continuous vibration may cause a decline in durability. Arrange piping to avoid excessive vibration or impacts. 5 XL-OMV0019 Models with solenoid valve 1. When mounting the fitting to the pilot port, mount it so that the solenoid valve and plate are secured at the same time.

Vibration resistance allows for normal operation of up to 30m/s2 (45 to 250Hz). Be advised that continuous vibration may cause a decline in durability. Arrange piping to avoid excessive vibration or impacts. 5 XL-OMV0003 High temperature type (temperature specification / H0 H4 H5) 1.

(The switch will stay ON all the time.) 1) Use a contact protection box when the wire length is 5m or longer. 2) Even if an auto switch has a built-in contact protection circuit, when the wiring is more than 30m long, it is not able to adequately absorb the rush current and its life may be reduced. It is again necessary to connect a contact protection box in order to extend its life.

Magnet: None, Mounting: A (Both Ends Tapped), Bore Size: 63mm, Port Thread Type: Rc, Stroke: 75mm, Body Option: Rod End Female Threads, Standard, Locking Direction: B (Retraction Locking)

Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: With fall prevention function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure(MPa): 0.25~1,

Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: With fall prevention function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure(MPa): 0.25~1,

Magnet: D (Built-in), Mounting: F (Front Flange), Bore Size: 50mm, Port Thread Type: TF (G), Stroke: 30mm, Body Option: M (Rod End Male Threads), Locking Direction: F (Extension Locking)

Magnet: D (Built-in), Mounting: L (Foot), Bore Size: 50mm, Port Thread Type: TF (G), Stroke: 30mm, Body Option: M (Rod End Male Threads), Locking Direction: F (Extension Locking)

Magnet: D (Built-in), Mounting: B [Through Hole (Standard)], Bore Size: 63mm, Port Thread Type: Rc, Stroke: 30mm, Body Option: M (Rod End Male Threads), Locking Direction: F (Extension Locking)

Magnet: D (Built-in), Mounting: A (Both Ends Tapped), Bore Size: 50mm, Port Thread Type: Rc, Stroke: 30mm, Body Option: M (Rod End Male Threads), Locking Direction: F (Extension Locking)

Magnet: None, Mounting: A (Both Ends Tapped), Bore Size: 63mm, Port Thread Type: TF (G), Stroke: 30mm, Body Option: M (Rod End Male Threads), Locking Direction: F (Extension Locking)

Magnet: D (Built-in), Mounting: G (Rear Flange), Bore Size: 50mm, Port Thread Type: Rc, Stroke: 30mm, Body Option: M (Rod End Male Threads), Locking Direction: F (Extension Locking)

Magnet: D (Built-in), Mounting: A (Both Ends Tapped), Bore Size: 63mm, Port Thread Type: TN (NPT), Stroke: 30mm, Body Option: M (Rod End Male Threads), Locking Direction: F (Extension Locking)

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: With fall prevention function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure(MPa): 0.25~1,

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: With fall prevention function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure(MPa): 0.25~1,

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: With fall prevention function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure(MPa): 0.25~1,

Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: With fall prevention function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure(MPa): 0.25~1,

Magnet: Built-in, Mounting: Front Flange, Bore Size: 50mm, Port Thread Type: G, Stroke: 30mm, Body Option: Rod End Male Threads, Locking Direction: Extension Locking, By-Pass Piping: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -

Magnet: Built-in, Mounting: B [Through Hole (Standard)], Bore Size: 63mm, Port Thread Type: Rc, Stroke: 30mm, Body Option: Rod End Male Threads, Locking Direction: Extension Locking, By-Pass Piping: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -

Magnet: Built-in, Mounting: Both Ends Tapped, Bore Size: 63mm, Port Thread Type: NPT, Stroke: 30mm, Body Option: Rod End Male Threads, Locking Direction: Extension Locking, By-Pass Piping: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -