SMC Corporation of America
Elite Part Number Search
Search Results "PVQ31-5G-16-01N"

Setting of Rotation Time Moment of Inertia 14 Kinetic Energy 16 Eternal Stopper 17 6. Maintenance and Inspection Standard Type 18 Standard Type 90, 180 Specification 19 Standard Type 270 Specification 20 With Auto Switch 21 7.

W (44) T R (Y) Z VC T 25 VDW IN port 2-3/8 : Thread type l=280 l=300 VQ VX2 (X) (V) S Q 2.5 (N) VX Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com C E A (U) VX3 D G C B VXA L1 L2 L3 16 VN LVC D side U side Stations 1 2 3 4 5 n LVA LVH LVD LVQ 21 5.5 16 OUT port n-

Series Option Example VV2DW2-0501 ... 1 set Manifold part no. 1 2 3 10 20 30 None With bracket Nil F VDW23-5G-2 ... 5 sets Valve part no. (Stations 1 to 5) Note) Type 30 is available only with bracket. "" is the symbol for mounting. Add "" in front of the part numbers for solenoid valves, etc., to be mounted. Enter together in order, counting from station 1 on the D side.

D side U side Stations 1 2 3 4 5 n 21 16 H H P=J (Pitch) OUT port n-1/4 n-1/8 T : Thread type 2 5.5 25 IN port 2-3/8 l=280 l=300 (V) (X) 2.5 (N) (U) E C D G Q S A C B L1 L2 16 L3 (44) W T R Z (Y) L dimensions (mm) n (stations) Model Dimension 4 3 5 9 2 6 10 7 8 138 103.5 172.5 310.5 L1 69 207 345 241.5 276 VV2CW2 150 115.5 184.5 322.5 L2 81 219 357 253.5 288 162 127.5 196.5 334.5 L3 93 231

W (44) Z (X) (V) T R (Y) T 25 IN port 2-3/8 l=280 l=300 2.5 (N) E A (U) S Q D G C C B L1 L2 L3 16 D side U side Stations 1 2 3 4 5 n 21 5.5 16 OUT port n-1/4 n-1/8 H H P=J (Pitch) 2 : Thread type L dimensions (mm) n (stations) Model Dimension 2 3 4 6 9 7 5 8 10 L1 69 103.5 138 207 310.5 241.5 172.5 276 345 VV2CW2 L2 81 115.5 150 219 322.5 253.5 184.5 288 357 L3 93 127.5 162 231 334.5 265.5

Series Option Example VV2DW2-0501 ... 1 set Manifold part no. 1 2 3 10 20 30 None With bracket Nil F VDW23-5G-2 ... 5 sets Valve part no. (Stations 1 to 5) Note) Type 30 is available only with bracket. "" is the symbol for mounting. Add "" in front of the part numbers for solenoid valves, etc., to be mounted. Enter together in order, counting from station 1 on the D side.

Base Mounted), Voltage: 5 (24VDC), Electrical Entry: G (Grommet), Orifice Size: 16 (1.6mm), Port Size: 01 [Base Mount w/Sub-Plate 1/8(6A) or Body Ported 1/8(6A)], Thread Type: N (NPT), Body/Seal Material: H (Body SUS, Seal FKM)

Type: Solenoid Valves, Application: Single Unit, Mounting Orientation: Direct, Voltage: DC24V, Specification: Standard, Actuation: [Single] Single, Status at Power Off: Self-Recovery (Spring Return), Valve Positions: 2-Position Normally Closed, Pipe Port Type: NPT, Port Size: 1/8, Pressure Rating(MPa): 0 to 1.0, Driving Type: Linear Motion Poppet, Seal Type: Soft Seal, Plumbing: Sub-Base

Example 1) 0.4MPa setting with 6 stations IRM10-6G-16 Example 2) 0.2MPa setting 2pcs., 0.4MPa setting 2pcs., 0.8MPa setting 1pc. with 5 stations IRM20-5G-021221 Copper-free specifications Ozone Resistant Specifications 3 Accessory (pressure gauge) Nil None Fluoro rubber is used for rubber seal materials.

Then, tighten the mounting screws to fix the valve to the manifold base. 4-7-16

Bore size (mm) Grease pack part no. 6 GR-S-005(5g) MXY6-PS Individual -X Set consists of 2 pieces of above 8 GR-S-010(10g) MXY8-PS !0, !

17 18 19 20 21 22 23 24 /01FD COMA B AXT100-DS25-015 1.5m AXT100-DS25-030 3m AXT100-DS25-050 5m MIL D AXT100-DS25-080 8m 25 AXT100-DS25-100 10m 25 0.3mm 2 AXT100-DS25-150 15m AXT100-DS25-200 20m AXT100-DS25-300 30m 11 No.VFS4000-OMY0001 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 6 3 5G 7 1) 2)()() 3)3 , 12 12 12 12 2 Nm M5 1.52 Rc 1/8 79 Rc 1/4 1214 Rc 3/8

PTFE Grease Specification Standard models -X446 Grease pack part number: GR-F-005(5g) 21 - Lubrication Caution 1) Lubrication for products using special grease Lubrication to this cylinder leads to operation failure. Otherwise, it may cause the operating failure. 2) Do not wipe off the grease on the sliding surface of the air cylinder.

Air or fluid leakage Check if air or fluid are leaking from the piping. 16 The product is noisy. Product failure Replace the product. (1) Check the wiring connection at the Copy function error Incorrect wiring FUNC terminal. Correct the wiring. 17 (2) Check the power supply wiring. Unable to copy Product failure Replace the product. -53No.PS-OMM0005-J Fault No.

PTFE Grease Specification Standard models -X446 Grease pack part number: GR-F-005(5g) Lubrication Caution 1) Lubrication for products using special grease Lubrication to this cylinder leads to operation failure. If grease other than those specified is used, it may cause the operating failure. 2) Do not wipe off the grease on the sliding surface of the air cylinder.

PTFE Grease Specification Standard models -X446 Grease pack part number: GR-F-005(5g) 22 - Lubrication Caution 1) Lubrication for products using special grease Lubrication to this cylinder leads to operation failure. Otherwise, it may cause the operating failure. 2) Do not wipe off the grease on the sliding surface of the air cylinder.

Thread type Rc NPT NPTF G Symbol Nil N T F VCL23-5G-2 ... 5 sets Valve part no. (Stations 1 to 5) Series "" is the symbol for mounting. Add a "" in front of the part numbers for solenoid valves, etc. to be mounted. 2 3 4 Class 2 Class 3 Class 4 Enter together in order, counting from station 1 on the D side.

19 19 n Lr 3.29 (83.5) 4.37 (1r1) 5.45 (38.5J 6.54 (i66) (1s05) 8.70 (2a) 9.78 (248.5) 10.87 \2761 11.95 {303.5) 13.03 (33') 14.11 (ss8,5) 15.20 (386) 16.28 (4r3.5) 17.36 (44r) 14.44 (468.5) 19.53 (496) 20.6"1 (523.5)2r.69 (551) t578.5) Ll 241 (71.3) 3.90 (ee) 4,94 u .5) 6.06 {1s4) (ra'.5) 4.23 (2og) 9.3i {23a51 10.39 (264) 11.44 (2s.s) '12.56 (3r9) 13.64 (346.5) 14.72 (374) 15-81 (4o.5) 16

Thread type Rc NPT NPTF G Symbol Nil N T F VCL23-5G-2 ... 5 sets Valve part no. (Stations 1 to 5) Series "" is the symbol for mounting. Add a "" in front of the part numbers for solenoid valves, etc. to be mounted. 2 3 4 Class 2 Class 3 Class 4 Enter together in order, counting from station 1 on the D side.