SMC Corporation of America
Elite Part Number Search
Search Results "PSE563-02-28"

Example) CUJ-M3 x 27 l C A A D B B Axial mounting Lateral mounting Without Auto Switch (Without Magnet) For Axial Mounting For Lateral Mounting C D A B 21 23 25 27 32 37 22 24 26 28 33 38 43 48 22 24 26 28 33 38 43 48 22 24 26 28 33 38 43 48 Cylinder model Mounting bolt size CUJB4-4 -6 -8 -10 -15 -20 CUJB6-4 -6 -8 -10 -15 -20 -25 -30 CUJB8-4 -6 -8 -10 -15 -20 -25 -30 CUJB10-4 -6 -8 -10 -15

AS2201F-01-06-X214 AS2301F-01-06-X214 RS H A AS2201F-01-06-X214 AS2301F-01-06-X214 AS2201F-02-06-X214 AS2301F-02-06-X214 RZQ 3. When disassembling to replace the seals and wear ring, refer to the separate disassembly instructions. AS3201F-02-08-X214 AS3301F-02-08-X214 AS3201F-02-08-X214 AS3301F-02-08-X214 MI W S 4.

AS2201F-01-06-X214 AS2301F-01-06-X214 RS H A AS2201F-01-06-X214 AS2301F-01-06-X214 AS2201F-02-06-X214 AS2301F-02-06-X214 RZQ 3. When disassembling to replace the seals and wear ring, refer to the separate disassembly instructions. AS3201F-02-08-X214 AS3301F-02-08-X214 AS3201F-02-08-X214 AS3301F-02-08-X214 MI W S 4.

Dimension L 21 273 22 285.5 23 298 24 310.5 25 323 26 335.5 27 348 28 360.5 29 373 30 385.5 No. Dimension L 31 398 32 410.5 33 423 34 435.5 35 448 36 460.5 37 473 38 485.5 39 498 40 510.5 50 Series SQ1000/2000 Manifold Options for SQ1000/SQ2000 Negative COM specifications The following valve part numbers are for negative COM specifications.

Snap rings (2) PC-01 PC-02 PC-03 PC-03 PC-05 Snap rings (2) PC-01 PC-02 PC-03 PC-03 PC-05 Clevis (1) RCS-015 RCS-02 RCS-03 RCS-04 RCS-05 Pin (1) PS-015 PS-02 PS-03 PS-03 PS-05 Clevis (1) RCD-015 RCD-02 RCD-03 RCD-04 RCD-05 Pin (1) PS-015 PS-02 PS-03 PS-03 PS-05 056 (9/16") 075 (3/4") 106 (1-1/16") 150 (1-1/2") 200 (2"), 250 (2-1/2") 056 (9/16") 075 (3/4") 106 (1-1/16") 150 (1-1/2") 200 (2

(Supply puressure: 0.3 to 0.5 MPa) Facility water outlet port *1 Rc1 36 to 38Nm 1.0 MPa or more Automatic fluid fill port Rc3/8 28 to 30Nm (Automatic fluid fill pressure: 0.2 to 0.5 MPa Overflow port Rc1 36 to 38Nm ID 25 mm or more Length 5m or less Tank drain port Rc3/4 28 to 30Nm ID 19 mm or more *1: Water cooled type only.

Model VQZ100 VQZ200 VQZ300 AN110-01 AN200-02 AN200-02 AN200-02 AN110-01 Port plug VVQZ100-CP (For VQZ100) This is used when changing piping location.

-04 (S) 4 7.2 9.6 12 1/8 13 (12.7) ASN AQ 24 AS231FS1-02-06 (S) 6 11.2 19 33.8 21.4 43.9 14.2 26 AS231FS1-02-08 (S) 8 13.2 34.9 23.5 46 15.6 27 AS231FS1-02-10 (S) 10 15.9 20.9 38.1 24.7 47.3 17 28 AS331FS1-02-06 (S) 6 8.2 16.5 29.9 17.5 40.1 13.3 1/4 17 (17.5) 12.9 13 49.7 48.3 44.2 42.8 21.5 16.2 ASV 49 AS331FS1-02-08 (S) 8 13.2 37.1 23.5 59.9 14.2 50 AS331FS1-02-10 (S) 10 15.9 17.4 23 41.2

For details, refer to page 2-4-28. Note 2) For details, refer to page 2-4-29.

Valve mounting direction ( ) 02 2 stations Single solenoid coil is located on the opposite side of the A, B port. -: : Single solenoid coil is located on same side as the A, B port.

Box 3385 Al-Amir Majed Street, Jeddah-21471, Saudi Arabia TEL: 02-6761574 FAX: 02-6708173 15-18-21

Proper tightening torque (Nm) Tightening torques for piping Connection thread Rc 1/8 Rc 1/4 Rc 3/8 Rc 1/2 Rc 3/4 7 to 9 12 to 14 22 to 24 28 to 30 28 to 30 5.

Port size Symbol Port size Size 30 50 60 75 100 02 03 04 Bracket Assembly (Accessory) Part No. $ $ 1/4 $ $ $ $ $ 3/8 Part no.

L plug connector (L): SYJ3 40-L-M5 M plug connector (M): SYJ3 40-M-M5 M8 connector (WO): SYJ3 40(R)-WO-M5 3 4 5 3 4 5 3 4 5 Approx. 300 (Lead wire length) 41.5 [48.5] 26.1 46 M8 x 1 28.5 52.6 [59.6] Approx. 300 (Lead wire length) 55.8 32.6 49.3 111.5 [115.9] R1 P R2 R1 P R2 R1 P R2 91.9 [96.3] 10 10 10 10 10 10 28 28 28 109.7 14 14 14 5 5 5 37.6 [39.8] 47.4 [49.6] 39.1 46.5 Refer to page

(W0): SYJ3240-W0-M5 M plug connector (M): SYJ3240-M-M5 Approx. 300 (Lead wire length) 41.5 [48.5] 26.1 46 M8 x 1 28.5 52.6 [59.6] Approx. 300 (Lead wire length) 98.6[103] 79 [83.4] R1 P R2 R1 P R2 R1 P R2 10 10 10 10 10 10 96.8 28 28 69 28 82 14 14 14 5 5 5 Refer to the page 91 for dimentions with connector cable. 9 Series SYJ3000 3 Position Closed Center/Exhaust Center/Pressure Center

Performance/Specifications General specifications LC5-1-T1-02 Part no.

Table 5.19-28 Operation setting when "Pump maintenance" alarm is generated Set value Explanation Initial value (Default setting) This alarm is not detected.

Rc 1/8 Body side VZA414-1P-01 VZA414-1P-02 VZA414-2P-01 VZA414-2P-02 VZA424-1P-01 VZA424-1P-02 VZA424-2P-01 VZA424-2P-02 Rc 1/8 Rc 1/4 Rc 1/8 Rc 1/4 Rc 1/8 Rc 1/4 Rc 1/8 Rc 1/4 M5 x 0.8 0.49 0.11 2.2 0.57 0.19 2.4 N.C. Sub-plate side M5 x 0.8 0.49 0.11 2.2 0.57 0.19 2.4 N.C. Body side M5 x 0.8 0.45 0.32 1.9 0.57 0.19 2.4 N.O. Sub-plate side M5 x 0.8 0.45 0.32 1.9 0.57 0.19 2.4 N.O.

B2B2 3 rev 1 (2) (1) 200 TM MR Configurator2 PC02 MBR (MBR)OFF(Tb) 0 ms 0 1000 PC03 *ENRS 0h 0 0 A B AB CCW CW A A 0 B B A A 1 B B 0 1 0 1 PC04 **COP1 C-1 0h 0 0 0 02 14 1()(16) 11.1.2 02 1: 4 116 11.1.2 5 21 5 No.

Data No.1 8 02 0106 sent. 9 01 02 004B 0001 01 02 01 Acquires the INP signal information.