Handle Position: Front, Piping: IN/OUT: Bottom, Fitting: IN: Straight Ø4, OUT: Straight Ø4, Accessory: Pressure Gauge, Option: -, Unit: -, Digital Pressure Switch Output Specifications: -
Sensor Range: 0 [Positive Pressure (0~1MPa)], Accuracy: ±1%F.S., Port Size: Ø6 Plug-In Reducer, Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]
Type: Pressure Sensor, Fluid Type: Air, Sensor, Monitor Structure: [Separate Type Connector Connection] Separated sensor, Output Method: Analog, Analog Output Specification: Voltage, Pipe Port Type: [One-Touch Couplings] One-Touch Couplings, Plumbing Thread Type: -, Plumbing Thread Nominal: -, Fluid Characteristics: Noncorrosive / Incombustible, Pressure Resistance(MPa): 1.5, Operating Temperature
Sensor Range: 1 [For Vacuum (0~-101kPa)], Accuracy: ±1%F.S., Port Size: Ø6 Plug-In Reducer, Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]
Sensor Range: 3 [For Compound Pressure (-100~100kPa)], Accuracy: ±1%F.S., Port Size: Ø6 Plug-In Reducer, Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]
Sensor Range: 1 [For Vacuum (0~-101kPa)], Accuracy: ±2%F.S., Port Size: Ø6 Plug-In Reducer, Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]
Sensor Range: 3 [For Compound Pressure (-100~100kPa)], Accuracy: ±2%F.S., Port Size: Ø6 Plug-In Reducer, Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]
Model: Branch Tee (Male Thread,Plug-in), Applicable Coaxial Tube: TW06B, Port Tube 1: Rod Ø6, Sealant 1: w/o Sealant, Port Tube 2: Single Tube Ø4, Sealant 2: -
Model: Branch Tee (Male Thread,Plug-in), Applicable Coaxial Tube: TW09B, Port Tube 1: Rod Ø6, Sealant 1: w/o Sealant, Port Tube 2: Single Tube Ø6, Sealant 2: -
(1PSE530) 2 Fst (PSE530 ) (PSE530 ) CPy SH1 Aon AoF ON -18No.PS-OMH0005CN-D 2 1 (PSE530 ) 2() LCD kPa kgf/cm 2 bar psi inHg mmHg kPa kgf/cm 2 bar psi MPa kgf/cm 2 bar psi LCD () () () () kPa MPa 3 1)OUT1 2)OUT2OUT1(CH1) OUT1 -19No.PS-OMH0005CN-D : : : : 2 digits 3 digits7 digits 7 digits -20No.PS-OMH0005CN-D 4 [ms] 5 -21No.PS-OMH0005CN-D 1OUT1P_1 P_1n_1 2OUT1P_2 P_2n
Sensor Range: 0 [Positive pressure (0 to 1 MPa)], Accuracy: ±2% F.S., Port Size: R06 (Ø6 Plug-In Reducer), Output Specification: N (NPN open collector 1 output), Lead Wire Termination: Basic, Set Value: P (Normal Output), OUT1 Set Value: 004 (0.4 MPa, −40 kPa, 40 kPa), OUT1 Hysteresis: 2 (0.02 MPa, 2 kPa, 2 kPa)
Sensor Range: 0 [Positive pressure (0 to 1 MPa)], Accuracy: ±2% F.S., Port Size: R06 (Ø6 Plug-In Reducer), Output Specification: P (PNP open collector 1 output), Lead Wire Termination: Basic, Set Value: P (Normal Output), OUT1 Set Value: 004 (0.4 MPa, −40 kPa, 40 kPa), OUT1 Hysteresis: 2 (0.02 MPa, 2 kPa, 2 kPa)
Sensor Range: 0 [Positive pressure (0 to 1 MPa)], Accuracy: ±2% F.S., Port Size: R06 (Ø6 Plug-In Reducer), Output Specification: P (PNP open collector 1 output), Lead Wire Termination: Basic, Set Value: P (Normal Output), OUT1 Set Value: 002 (0.2 MPa, −20 kPa, 20 kPa), OUT1 Hysteresis: 2 (0.02 MPa, 2 kPa, 2 kPa)
Sensor Range: 0 [Positive pressure (0 to 1 MPa)], Accuracy: ±2% F.S., Port Size: R06 (Ø6 Plug-In Reducer), Output Specification: P (PNP open collector 1 output), Lead Wire Termination: Basic, Set Value: P (Normal Output), OUT1 Set Value: 004 (0.4 MPa, −40 kPa, 40 kPa), OUT1 Hysteresis: 4 (0.04 MPa, 4 kPa, 4 kPa)
Handle Position: A (Upper), Piping: 1 (IN/OUT: Bottom), Fitting: 06 (IN: Straight Ø4, OUT: Straight Ø4), Accessory: A (Pressure Gauge), Option: None, Unit: ZA [Digital Pressure Switch w/Unit Switching Function (MPa)], Digital Pressure Switch Output Specifications: P (PNP open collector)
Series PSE digital pressure switches allow pressure to be controlled from a remote location. Series PSE510 is compact and lightweight, allowing the sensor to be mounted where needed. The use of stainless steel for all wetted parts (SUS630 for diaphragm, SUS304 for fitting) allows the PSE520 pressure sensor to be used in a wide variety of gas and fluid applications. Pressure sensor for multi-channel
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
PSE531 and PSE533 are remote vacuum sensors with a 1 to 5V analog signal output. 531 is for low vacuum range of -101 to 0 kPa, while PSE533 is for compound pressure from -101 to 101 kPa. PSE sensors can monitor any non-corrosive, non-flammable gas. The accuracy and environmental capabilities are suitable for general purpose applications. The cable is replaceable, with a locking thread
PSE531 and PSE533 are remote vacuum sensors with a 1 to 5V analog signal output. 531 is for low vacuum range of -101 to 0 kPa, while PSE533 is for compound pressure from -101 to 101 kPa. PSE sensors can monitor any non-corrosive, non-flammable gas. The accuracy and environmental capabilities are suitable for general purpose applications. The cable is replaceable, with a locking thread
R06 6 mm PSE53-R07 1/4 inch -14No.PS-OME0003CN-F A B C D E F [October 2017] 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021 JAPAN Tel: + 81 3 5207 8249 Fax: +81 3 5298 5362 URL http://www.smcworld.com Note: Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. 2010-2017 SMC Corporation All Rights Reserved.