SMC Corporation of America
Elite Part Number Search
Search Results "PFM550-01-1-N-WR"

Prepare a cable, referring to Fig 3.3-1 or Fig. Terminal resistance 1 SD+ 1 SD+ 1 SD+ 5 SG 9 SDSD+ SDSG 5 SG 9 SD5 SG 9 SDTerminal resistance120 Master This product (first slave) This product second slave This product 31st slaves Fig 3.3-1 RS-485 connector connection Tips 1 master : 1 product, or 1 master: N products. In the latter case, up to 31 products can be connected.

1 1 3 3 3 3 18AWG BK 3 3 1 1 1 1 C3 (CN51) (CN1) (CN6) Compressor CM CM AC Power Board 3 1 PCB1 3 3 [ ] TH 14AWG BK 14AWG BK C CM 2 Current Transformer S 14AWG G/Y G3 [ ] [ ] 14AWG BK S Condenser Circuit Protector R C1 E CT 1 14AWG G/Y G1 [ ] CP R 1 1 [ ] R [ ] 14AWG BK 14AWG BK N (CN4) N [ ] 14AWG BK 14AWG BK 2 2 22 21 L L L [ ] [ ] 14AWG BK 14AWG BK 1 1 12 11 (CN2) WH BK 3 12 12 3 3 BR

How to Order 2 1 01 06 2 AS 1 F E S K Hexagonal lock nut Body size 2 3 4 1/8, 1/4 3/8 1/2 Sealant Applicable tube O.D.

connecter G L LO M MO Y YO YZ YOS (1) Standard (1) High pressure (Metal seal only) (1) (1.0W) K (1) Model Sub-plate part No. (1) (0.5W) Y Low wattage (2) (1) VQZ100-S-01(R) VQZ100 (1.0W) (3) L Latching (2) 01[Rc1/8] 02[Rc1/4] 02 [Rc1/4] 03 [Rc3/8] VQZ200-SVQZ200 Note 1) Option Note 2) When specifying more than one option, please indicate them alphabetically.

(P) 5(R1) 3(R2) 1(P) 5(R1) 3(R2) 1(P) 5(R1) 3(R2) 1(P) 5(R1) None Nil IN side port size OUT side port size DIN rail mounting (For manifold) D 01 02 C6 C8 N7 N9 Rc 1/8 Rc 1/4 6 One-touch fitting 8 One-touch fitting 1/4" One-touch fitting 5/16" One-touch fitting 01 02 C6 C8 N7 N9 Rc 1/8 Rc 1/4 6 One-touch fitting 8 One-touch fitting 1/4" One-touch fitting 5/16" One-touch fitting F With bracket

T (M) L2 L1 M Nylon Urethane 1 4 13 13 M12 X 1 3.2 KQ2E23-02 3.4 2.9 17 14 14 31.5 15 15.5 1 8 KQ2E04-01 11 5.6 4 16 13 16 27.5 31 M12 X 1 4 14 1 4 1 8 1 4 3 8 1 8 1 4 3 8 1 4 3 8 3 8 1 2 3 8 1 2 15 35 KQ2E04-02 17 KQ2E06-01 11 28 31.5 30 15 17 M14 X 1 19 KQ2E06-03 17 33.5 29 KQ2E06-02 15 6 13.1 10.4 17 17 17 KQ2E08-01 7.5 27.5 28 26.1 18.0 8 18.5 19 KQ2E08-02 13 33 27 17 M16 X 1 19 KQ2E08

output signal 1 function RUN 1 D.OUT1 SEL 5.5.5 No.13 screen Contact output ignal 1 operation A A/B D.OUT1 TYPE No.14 screen Contact output signal 1 alarm AL.01 AL.01AL.32 D.OUT1 ALARM CODE No.15 screen Contact output signal 1 maintenance MT.01 MT.01MT.05 D.OUT1 MANT CODE No.16 screen Contact output signal 2 function RMT 1 D.OUT2 SEL No.17 screen Contact output signal 2 operation A

Prepare a cable, referring to Fig 3.3-1 or Fig. Terminal resistance 1 1 1 9 5 9 5 9 5 SDSD+ SDSG SD+ SD+ SD+ SG SDSG SDSG Terminal resistance120 Master This product This product This product (first slave) second slave 31st slaves Do not connect any wire to other PIN numbers. Fig 3.3-1 RS-485 connector connection Tips 1 master : 1 product, or 1 master: N products.

Proof pressure Max. operating pressure Set press. range Air operated Solenoid Ambient and fluid temperature Hysteresis Repeatability Sensitivity Mounting Lubrication Port 01 P A R mm2 02 01 02 03 04 04 06 10 10 12 14 20 02 Port size Rc(PT) 1 11 2 1 4 11 4 1 2 1 8 1 4 1 8 1 4 1 4 3 8 1 2 1 2 3 4 590 2 1 300 17 25 1.4 16 0.9 25 1.4 60 3.3 70 3.9 330 18 36 2.0 Cv 16 0.9 130 7.2 160 8.9 180 10

IR How to Order VEX VVEXB 5 01 1 AMR Pilot type 01 Port size Body size ITV Thread type Nil F N T Rc G NPT NPTF 8 1 IC Internal pilot Common external pilot 1 2 Valve stations VBA 2 2 stations VE 10 10 stations VY1 VVEX2 5 02 1 G Pilot type 02 Port size Body size Thread type PPA Nil F N T Rc G NPT NPTF 4 1 AL Internal pilot Common external pilot 1 2 Valve stations 2 2 stations 8 8 stations

Symbol 20 25 30 40 50 60 01 02 03 04 06 10 1/8 1/4 3/8 1/2 3/4 1 Name plate and pressure gauge in imperial units (PSI, F) When more than one specification is required, indicate in ascending alphanumeric order.

port: Rc 1/8 P port: Rc 1/8 R port: Rc 1/8 Thread type Type S42 20 20 stations Solenoid on same side of A and B port Type VK334 Type VK3140 V100 S Nil Rc Q CE-compliant Nil CE-compliant Port size R port: Rc 1/8 P port: Rc 1/8 F N T G S070 1 8 NPT 01 Rc C6 6 cassette B port: Rc 1/8 A port: Rc 1/8 NPTF Note) Applicable only for DIN terminal type VQD VQD-V Common SUP/Common EXH Type 21: Body

Valve diagnostics 1 . 5-4 Valve diagnostics 1 Bit 0 Valve 0, 1 diagnostics 01() 1 Valve 2, 3 diagnostics 01() 2 Valve 4, 5 diagnostics 01() 3 Valve 6, 7 diagnostics 01() 4 Valve 8, 9 diagnostics 01() 5 Valve 10, 11 diagnostics 01() 6 Valve 12, 13 diagnostics 01() 7 Valve 14, 15 diagnostics 01() 5.1.1.4.

Same mounting brackets and accessories are used as Series CM2 (Best Pneumatics No. 2). 1036 Sine Cylinder Series REC Minimum Stroke for Auto Switch Mounting n: No. of auto switches (mm) No. of auto switches mounted Auto switch model 1 2 n Same surface Same surface Different surfaces Different surfaces D-A9 D-M9 D-M9W (n 2) 2 15 + 45 10 Note) Note) 15 45 45 + 45 (n 2) (n = 2, 4, 6, ) (n

Same mounting brackets and accessories are used as Series CM2 (Best Pneumatics No. 2). 1036 Sine Cylinder Series REC Minimum Stroke for Auto Switch Mounting n: No. of auto switches (mm) No. of auto switches mounted Auto switch model 1 2 n Same surface Same surface Different surfaces Different surfaces D-A9 D-M9 D-M9W (n 2) 2 15 + 45 10 Note) Note) 15 45 45 + 45 (n 2) (n = 2, 4, 6, ) (n

side of A port Nil 1 8 01 Rc VFN Nil Rc G NPT NPTF C4 4 cassette P port: Rc 1/8 R port: Rc 1/8 A port: Rc 1/8 F N T Same side of A port S C6 6 cassette Valve stations Type S42 (Solenoids on the same side of A port) 01 1 station 20 20 stations P port: Rc 1/8 R port: Rc 1/8 A port: Rc 1/8 Common SUP/Individual EXH How to Order Type 21: Body ported (A port top ported) Applicable solenoid valve

(Type DZ only) 67.5 59 32 17 2 2-4.5 (Mounting hole) P mPm P 19 35 Pg.7 2-Rc 1/8 1(P) port A A A 11 20 26 49 300 (lead wire length) 1 P = 19 13.5 L2 5.5 L1 47.5 11 5 n-Rc 1/8, M5 x 0.8 2(A) port 19 35 n-Rc 1/8 3(R) port 47.5 11 R R P = 19 19 L Dimension n: Stations n L 1 38 27 2 57 46 3 76 65 4 95 84 5 114 103 6 133 122 7 152 141 8 171 160 9 190 179 10 209 198 11 228 217 12 247 236 13 266

(mm) Weight (g) (1) D Applicable tubing KGH04-M5 KGH04-01 4 M5 x 0.8 4 2.4 9 16 4 1 4 KGH04-02 19.5 13.5 14 4 8 17 22 8 14 13 4 1 8 10 16 18 5.6 M5 x 0.8 KGH06-M5 KGH06-01 KGH06-02 14 3.4 16 14 4 10 12 14 18.5 22.5 23 10 15 18.5 17 1 8 1 4 6 13.1 10.4 17 3 8 KGH06-03 22 15.5 17 27 21 19 26 19 30 Connection thread 1 8 1 4 3 8 1 8 1 4 KGH08-01 KGH08-02 KGH08-03 KGH10-01 KGH10-02 28

output signal 1 function RUN 1 D.OUT1 SEL 5.5.5 No.13 screen Contact output ignal 1 operation A A/B D.OUT1 TYPE No.14 screen Contact output signal 1 alarm AL.01 AL.01 to AL.32 D.OUT1 ALARM CODE No.15 screen Contact output signal 1 maintenance MT.01 MT.01 to MT.05 D.OUT1 MANT CODE No.16 screen Contact output signal 2 function RMT 1 D.OUT2 SEL No.17 screen Contact output signal 2 operation