Rc1/8 R, Rc1/4 R, Rc3/8 R, Rc1/2 NPT1/8 NPT1/4 NPT3/8 NPT1/2 Hose nominal 6 (1/4") 8 (1/4") 9 (3/8") 12 (1/2") Applicable hose I.D.
2 Series IR3000 Connection Rc(PT) 1/8 01 Connection Rc(PT) 1/4 02 Connection Rc(PT) 3/8 03 Connection Rc(PT) 1/2 04 Bracket B Accessories Pressure gauge G Pressure gauge reverse mounted R Connection NPT1/8 N01 Series IR2000 Connection NPT1/4 N02 Connection NPT3/8 N03 Connection NPT1/2 N04 Connection G(PF) 1/8 F01 Connection G(PF) 1/4 F02 Connection G(PF) 3/8 F03 Connection G
Dimensions 4 EXH port 1/8 Input signal port( PIL ) R port Supply pressure exhaust port 2 x 1/8 Output port 2( A ) Supply port on the other side 1( P ) 2 x M6 x 1 thread depth 8 (Panel mounting screw) Panel mounted Bracket mounted 2 x 6.5 hole (Mounting screw M6 x 1 x 12) Handle side 4 x M6 screw 4 x 7 hole on the bracket side Bracket plate thickness t = 2 Panel plate thickness t = 3 or less
SMC Pneumatics, IncorporaH (SMC) warrantg that lor 1 I months or 18OO se.vice milis', whictrewr dccuis rrs!
Note 3) The handle of the selector (2 position) cannot be removed or replaced alone. 5-6-35 Series VZM400 How to Order S 01 01 0 VZM45 Option Suffix for actuator F Foot bracket (Only internal pilot) Actuator type R S G B Red Hard steel roller Port size Basic 00 Color of push botton selector Rc 01 1 8 NPT N01 1 8 G F01 1 8 Roller lever 01 Black One Way Roller Lever 02 Green Straight plunger
Flow Rate Range: 25 [0.5 to 25 (12.5 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: N01 (NPT1/8), Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)], Instruction Manual: With Instruction Manual, Calibration Certificate: A (w/Calibration Certificate), Connector: W [Lead Wire w/Connector (2m) + Rubber Cover], Option: R (Bracket for w/o Flow Adjustment
Flow Rate Range: 25 [0.5 to 25 (12.5 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: N01 (NPT1/8), Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)], Instruction Manual: With Instruction Manual, Calibration Certificate: A (w/Calibration Certificate), Connector: W [Lead Wire w/Connector (2m) + Rubber Cover]
Flow Rate Range: 25 [0.5 to 25 (12.5 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: N01 (NPT1/8), Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)], Instruction Manual: N (None), Calibration Certificate: None, Connector: Z (w/o Lead Wire w/Connector)
Flow Rate Range: 25 [0.5 to 25 (12.5 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: N01 (NPT1/8), Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)], Instruction Manual: With Instruction Manual, Calibration Certificate: A (w/Calibration Certificate), Connector: Z (w/o Lead Wire w/Connector)
Flow Rate Range: 25 [0.5 to 25 (12.5 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: NPT1/8, Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)], Instruction Manual: With Instruction Manual, Calibration Certificate: w/Calibration Certificate, Connector: W [Lead Wire w/Connector (2m) + Rubber Cover], Option: Bracket for w/o Flow Adjustment Valve:
Flow Rate Range: 25 [0.5 to 25 (12.5 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: NPT1/8, Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)], Instruction Manual: With Instruction Manual, Calibration Certificate: w/Calibration Certificate, Connector: W [Lead Wire w/Connector (2m) + Rubber Cover], Option: -
Flow Rate Range: 25 [0.5 to 25 (12.5 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: NPT1/8, Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)], Instruction Manual: None, Calibration Certificate: None, Connector: w/o Lead Wire w/Connector, Option: -
Flow Rate Range: 25 [0.5 to 25 (12.5 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: NPT1/8, Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)], Instruction Manual: With Instruction Manual, Calibration Certificate: w/Calibration Certificate, Connector: w/o Lead Wire w/Connector, Option: -
(A) 2 23 (AR) (A) 2 Refer to Best Pneumatics No. 1 for further details. 3 (R) 1 (P) 3 (R) 1 (P) Regulator Series AR Model Specifications Model AR20 Port size 1/8, 1/4 AR25 1/4, 3/8 AR30 1/4, 3/8 AR40 AR20 AR25 AR30 AR40 Model Proof pressure 1.5 MPa 1.0 MPa 0.05 to 0.85 MPa 1/4, 3/8, 1/2 Max. operating pressure Pressure gauge port size 1/8 1/4 Set pressure range Ambient and 5 to 60C (No freezing
Suffix R: Bracket, Name plate, Mounting on the opposite side Note1) Type of setting 1 : Air operated Accessories NIL: None B: Bracket (P36203018) G: Pressure gauge Note2) Note3) Thread type when Rc and G. Thread type when NPT. G43-10-01 G43-P10-N01-X30 Port size 02 : 1/4 03 : 3/8 04 : 1/2 2 : 0.010.8MPa Set pressure Thread type NIL:Rc F:G N:NPT 4.
Suffix R: Bracket, Name plate, Mounting on the opposite side Note1) Type of setting 1 : Air operated Port size 02 : 1/4 Note4) Accessories NIL: None B: Bracket (P36202028) G: Pressure gauge Note2) Note3) Thread type when Rc and G. Thread type when NPT. IR2120 : G43-10-01 G43-P10-N01-X30 2 : 0.010.8MPa Set pressure Thread type NIL:Rc F:G N:NPT 4.
Note 3) The handle of the selector (2 position) cannot be removed or replaced alone. 5-6-41 Series VZM500 How to Order S 01 01 0 VZM55 Option Suffix for actuator F Foot bracket Actuator type R S G B Red Hard steel roller Port size Basic 00 Color of push button selector Rc 01 1 8 Roller lever 01 Black 1 8 NPT N01 One way roller lever 02 Green G F01 1 8 Straight plunger 05 Y Yellow Roller plunger
output P PNP open collector 1 output Symbol Description Nil Units selection function1 M SI unit only2 P Units selection function (Initial value psi)1 1 Under the New Measurement Act, switches with the units selection function are not permitted for use in Japan. 2 Fixed unit: kPa, MPa y Option 2 t Option 1 r Piping specification Symbol Description Nil None Symbol Description Symbol Description
output P PNP open collector 1 output Symbol Description Nil Unit selection function1 M SI unit only2 P Unit selection function (Initial value psi)1 1 Under the New Measurement Act, switches with the unit selection function are not permitted for use in Japan. 2 Fixed unit: kPa, MPa y Option 2 t Option 1 r Piping specification Symbol Description Nil None Symbol Description Symbol Description
Repeatability 1%F.S. 1 digit Hysteresis Hysteresis mode 0 to variable 1 Window comparator mode Output Voltage (rated pressure range) Voltage output 1 to 5 V 2.5%F.S. 2 Linearity 1.5%F.S. 1%F.S.