ITV X88 2 0 1 0 S 0 1 2 High-speed response time specifications Model Pressure range 1 2 1000 type 2000 type 1 3 5 0.1 MPa 0.5 MPa 0.9 MPa Pressure display unit 2 3 4 5 MPa kgf/cm2 bar PSI kPa Power supply voltage Input signal 0 1 24 VDC 12 to 15 VDC 0 1 2 3 Current 4 to 20 mA (Sink type) Current 0 to 20 mA (Sink type) Voltage 0 to 5 VDC Voltage 0 to 10 VDC Cable connector type S L N Straight
Port 3/4 3/4, 1 D I M E N S I O N S AD S E R I E S A U I T O D R A I N S S Y M B O L S H O W T O O R D E R A U T O D R A I N S E R I E S AD AD402-02 (1/4) PT AD402-03 (3/8) PT AD402-04 (1/2) PT AD600-06 (3/4) PT AD600-10 (1) PT H O W T O O R D E R A U T O D R A I N S E R I E S NAD NAD402-N02 (1/4) NPT NAD402-N03 (3/8) NPT NAD402-N04 (1/2) NPT NAD600-N06 (3/4) NPT NAD600-N10 (1) NPT FOR FURTHER
@-@n-m a 16 points preset type Note 1) E in parl number is lhe same modelno. for the standard products.
M E N S I O N S AD S E R I E S A U I T O D R A I N S S Y M B O L S H O W T O O R D E R A U T O D R A I N S E R I E S AD AD402-02 (1/4) PT AD402-03 (3/8) PT AD402-04 (1/2) PT AD600-06 (3/4) PT AD600-10 (1) PT H O W T O O R D E R A U T O D R A I N S E R I E S NAD NAD402-N02 (1/4) NPT NAD402-N03 (3/8) NPT NAD402-N04 (1/2) NPT NAD600-N06 (3/4) NPT NAD600-N10 (1) NPT FOR FURTHER TECHNICAL DETAILS
pressure value (main display). (1) Press and hold the button between 1 and 3 seconds in measurement mode.
CFM x 10-2 1 CFM x 10-2 Accumulated Setting/Display flow range 0.0 to 9.0 0.0 to 9.9 0 to 9 0 to 9 ft3 x 10-1 ft3 x 10-1 ft3 x 10-1 ft3 x 10-1 flow Min. setting/display unit 0.1 ft3 x 10-1 0.1 ft3 x 10-1 1 ft3 x 10-1 1 ft3 x 10-1 Conversion of accumulated pulse 0.1 1 1 1 ft3 x 10-1/pulse ft3 x 10-1/pulse ft3 x 10-1/pulse ft3 x 10-1/pulse : Flow rate in the specification is the value at standard
1 !0oi q w e r t y u i !1 !2 No.
IRM 10 3 G ARJ A IR X465 0 AR425 to 935 Set pressure and quantity 0 1 2 0.2 MPa setting 1 to n pcs. 0.4 MPa setting 1 to n pcs. 0.8 MPa setting 1 to n pcs.
IRM 10 3 G Standard model no. 80 OUT OUT OUT OUT OUT Set pressure and quantity 0 1 2 0.2 MPa setting 1 to n pcs. 0.4 MPa setting 1 to n pcs. 0.8 MPa setting 1 to n pcs.
Barb fitting type (for rubber hose) Barb fitting type (for rubber hose) Model Hose nominal Model Hose nominal KK130P-07B -09B -11B -13B KK130S-07B -09B -11B -13B 6 (1/4") 6 (1/4") 8 (1/4") 8 (1/4") 9 (3/8") 9 (3/8") 12 (1/2") 12 (1/2") The figures in ( ) indicate the internal diameter of the applicable hose.
connector S L N Option Option Monitor output Bracket Thread type 0 None (for preset input) Analog output 1 to 5V DC Switch output/NPN output Switch output/PNP output Analog output 4 to 20mA Without bracket Flat bracket L-bracket B Port size Rc(PT) NPT NPTF G(PF) 1 2 N T 1/4 (2000, 3000) 3/8 (2000, 3000) 1/2 (3000) 2 3 4 C 3 Option 4 F 1.12-1 Option Option Series ITV2000
IRM 10 3 G Copper-free Specifications 2 Set pressure and quantity External and internal copper parts are changed to stainless steel or aluminum. 0.2MPa setting 1 to n pcs. 0.4MPa setting 1 to n pcs. 0.8MPa setting 1 to n pcs. 0 1 2 Standard part number 20 Note) Contact SMC if equipped with pressure gauge.
M 1 2 x 1 Cable connection threads suP (1) 2-Ro(PT) 114,318, 1/2 Port size Mounting hole L-bracket tNt-398-0-6 (optional) 2-Rc(PT) 1/4,3/8, 1/2 SUP port, OUT port Eleclno-Pltoulnalic Relulatnn rTUz000/3 lt'iler ilile $ruciliciliotts 2 through I station manifold.
Flow Rate Range: 11 [2 to 100 (50 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: N7 (ø1/4 One-touch Fitting), Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)], Instruction Manual: N (None), Calibration Certificate: None, Connector: Z (w/o Lead Wire w/Connector)
Flow Rate Range: 11 [2 to 100 (50 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: C8 (ø8 (5/16") one-touch fitting), Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)], Instruction Manual: N (None), Calibration Certificate: None, Connector: Z (w/o Lead Wire w/Connector)
Flow Rate Range: 11 [2 to 100 (50 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: C6 (ø6 One-touch Fitting), Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)], Instruction Manual: N (None), Calibration Certificate: None, Connector: Z (w/o Lead Wire w/Connector)
Flow Rate Range: 11 [2 to 100 (50 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: ø1/4 One-touch Fitting, Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)], Instruction Manual: None, Calibration Certificate: None, Connector: w/o Lead Wire w/Connector, Option: -
Flow Rate Range: 11 [2 to 100 (50 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: ø8 (5/16") one-touch fitting, Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)], Instruction Manual: None, Calibration Certificate: None, Connector: w/o Lead Wire w/Connector, Option: -
Flow Rate Range: 11 [2 to 100 (50 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: ø6 One-touch Fitting, Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)], Instruction Manual: None, Calibration Certificate: None, Connector: w/o Lead Wire w/Connector, Option: -
2-Color Display Digital Pressure Switch For General Fluids Series ZSE80/ISE80 How to Order Rated pressure range 80 80H 0.1 to 1 MPa 0.1 to 2 MPa Made to Order Refer to Table 1 below.