Rated Flow Range: 11 (10 to 100 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 10 (1), Output Specification: 1 (OUT1: Analog 1 to 5V), Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: G (Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C), Bracket: None, Calibration Certificate: None, Made to Order: X109 (EPDM Seal Material
Rated Flow Range: 10 to 100 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 1, Output Specification: OUT1: Analog 4 to 20mA, Temperature Sensor: OUT2: Analog 1 to 5V, w/Temperature Sensor, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C, Bracket: None, Calibration Certificate: None, Made to Order: Analog
Rated Flow Range: 10 to 100 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 1, Output Specification: OUT1: Analog 4 to 20mA, Temperature Sensor: OUT2: Analog 1 to 5V, w/Temperature Sensor, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C, Bracket: Bracket, Calibration Certificate: None, Made to Order: Analog
Rated Flow Range: 10 to 100 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 1, Output Specification: OUT1: Analog 4 to 20mA, Temperature Sensor: OUT2: Analog 1 to 5V, w/Temperature Sensor, Lead Wire: w/o Lead Wire w/M8 Connector, Units on Label: Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C, Bracket: Bracket, Calibration Certificate: None, Made to Order: Analog
Rated Flow Range: 10 to 100 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 1, Output Specification: OUT1: Analog 4 to 20mA, Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C, Bracket: Bracket, Calibration Certificate: None, Made to Order: EPDM Seal Material
Rated Flow Range: 10 to 100 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 1, Output Specification: OUT1: Analog 4 to 20mA, Temperature Sensor: OUT2: Analog 1 to 5V, w/Temperature Sensor, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C, Bracket: Bracket, Calibration Certificate: Calibration Certificate
Rated Flow Range: 10 to 100 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 1, Output Specification: OUT1: Analog 4 to 20mA, Temperature Sensor: OUT2: Analog 1 to 5V, w/Temperature Sensor, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C, Bracket: None, Calibration Certificate: Calibration Certificate,
Rated Flow Range: 10 to 100 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 1, Output Specification: OUT1: Analog 1 to 5V, Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C, Bracket: None, Calibration Certificate: None, Made to Order: EPDM Seal Material
(Plug-in type) VVQ5000-P-5T (Plug lead type) 03 04 03 04 32 16 By mounting individual SUP spacers on a manifold block, it is possible to provide individual supply ports for each valve. 1 P 40.3 1(P) 4(A) 2(B) 03: 3/8 04: 1/2 1(P') 5(R1) 3(R2) Circuit diagram Plug-in type Plug lead type Individual EXH spacer 179 (plug-in type) 133 (plug lead type) VVQ5000-R-1T (Plug-in type) VVQ5000-R-5T
Mtrual opralor assmbly $llh Odng PA0@1 PBO{01 I 1 Raplacdr3nl coll only-4.C. sol6nold 1Al0 aot@ 1O/@ cl2A{9 cl2A-10 cl2A.1t 10 I Sol6noi, aBsmbly-4,C. conplst wllh coll, 120/ao 24(m0 a0,t0 @14O9 @ta-10 cora-1t At2A{9 412A,10 1 l '| NXT01010 NXT0307.3 12 1 NXTO1G12 NXTO1G12 13 @t|vo scr6w .nd locl wa5hsr xTt)10-21 xT010.21 DIRECTIONAL AIR YALVE MANIFOLD ASSEMBLY SERIES NVS 3115, 3125 NVS 3135
ts 4 ly""iliffifl"yi;i'':1t.:ti Statlons 02-2 stations System type. AEjectors B External Vacuum 'For plug (X) posirioning onty.
ts 4 ly""iliffifl"yi;i'':1t.:t Statlons 02-2 stations System type. AEjectors B External Vacuum 'For plug (X) posirioning onty.
(Plug-in type) VVQ5000-P-5T (Plug lead type) 03 04 03 04 32 16 By mounting individual SUP spacers on a manifold block, it is possible to provide individual supply ports for each valve. 1 P 40.3 1(P) 4(A) 2(B) 03: 3/8 04: 1/2 1(P') 5(R1) 3(R2) Circuit diagram Plug-in type Plug lead type Individual EXH spacer 179 (plug-in type) 133 (plug lead type) VVQ5000-R-1T (Plug-in type) VVQ5000-R-5T
Rc Special voltage With light Without DIN connector (With surge voltage suppressor) G 24 VAC 12 VDC 48 VAC NPT 1K 1L Rc 220 VAC 240 VAC Applicable to air and water (VXN<2) Conduit terminal 1M 1W (With surge voltage suppressor) 24 VAC 12 VDC 48 VAC 1N 1P 1Q 1R 1Y 1S 1T 2A 2B 2C 2D 2E 2F Enter symbols in the order below when ordering a combination of electrical option, other option. 220 VAC
Valve; w/Stop Valve), Supply/Return Port Size: 03 (3/8), Return Unit Flow Switch Output Specifications: 1T (Out 1: Analog 1 to 5 V; Out 2: Flow Rate: None; Temp.: Analog 1 to 5 V; Temperature Sensor: Yes)
Valve; w/Stop Valve), Supply/Return Port Size: 03 (3/8), Return Unit Flow Switch Output Specifications: 1T (Out 1: Analog 1 to 5 V; Out 2: Flow Rate: None; Temp.: Analog 1 to 5 V; Temperature Sensor: Yes)
Valve: None; Stop Valve: None, Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: 1T (Out 1: Analog 1 to 5 V; Out 2: Flow Rate: None; Temp.: Analog 1 to 5 V; Temperature Sensor: Yes)
MSU OTHER SIZE RATING. .41424 lb. 1T.
MSU OTHER SIZE RATING. .42990 lb. 1T.
MSU OTHER SIZE RATING. .55115 lb. 1T.