Foot CS1-L12 CS1-L14 CS1-L16 Flange CS1-F12 CS1-F14 CS1-F16 Precautions Single clevis CS1-C12 CS1-C14 CS1-C16 Double clevis CS1-D12 CS1-D14 CS1-D16 Order 2 foot brackets for one cylinder. Auto Switch Mounting Bracket Part No. Be sure to read before handling. Refer to p.0-39 to 0-43 for Safety Instructions and common precautions.

Bore size (mm) 125 140 160 Foot CS2-L12 CS2-L14 CS2-L16 Flange CS2-F12 CS2-F14 CS2-F16 Single clevis CS2-C12 CS2-C14 CS2-C16 Double clevis CS2-D12 CS2-D14 CS2-D16 Order two foot brackets per cylinder. When ordering the double clevis style, the clevis pin and 2 split pins are included as accessories. 3

CS1-F12 CS1-F14 CS1-F16 Head side flange style CS1-C12 CS1-C14 CS1-C16 Single knuckle joint CS1-D12 CS1-D14 CS1-D16 Double knuckle joint (3) Note 1) When ordering foot bracket, order 2 pieces per cylinder. Note 2) 125 to 160 rod side flange styles use Series CS1 long stroke flanges. Note 3) Clevis pin and cotter pin (2 pcs.) are shipped together with double clevis style.

port size A AA B D E F G H J K L N P Model 11/4, 11/2 104 74 31 52 39.5 PF3W721 25 27.5 3.5 depth 14 G 11/4 108 76 33 54 41.5 56 91 71.6 28.5 54 G 11/2 112 78 35 56 43.5 -85No.PF-OMM0005-N PF3W704/720/740/711/721 (With temperature sensor) Temperature sensor Symbol A AA Model PF3W704--T 81 50 PF3W720--T 89 54 PF3W740--T 109 71 PF3W711--T 135 92 PF3W704--T 115 74 PF3W721-F12-T 119 76 PF3W721-F14

Foot style CS1-L12 CS1-L14 CS1-L16 CS1-L18 CS1-L20 CS1-L25 CS1-L30 Flange style CS1-F12 CS1-F14 CS1-F16 CS1-F18 CS1-F20 CS1-F25 CS1-F30 Single clevis style CS1-C12 CS1-C14 CS1-C16 CS1-C18 CS1-C20 CS1-C25 CS1-C30 Double clevis style CS1-D12 CS1-D14 CS1-D16 CS1-D18 CS1-D20 CS1-D25 CS1-D30 Order two foot brackets per cylinder.

CS1-F12 CS1-F14 CS1-F16 CS1-F18 CS1-F20 CS1-F25 Single clevis type CS1-C12 CS1-C14 CS1-C16 CS1-C18 CS1-C20 CS1-C25 Double clevis Note 3) CS1-D12 CS1-D14 CS1-D16 CS1-D18 CS1-D20 CS1-D25 Note 1) When ordering foot brackets, 2 pcs. should be ordered for each cylinder. Note 2) 125 to 250 front flange types use series CS1 long stroke flanges.

Switch for Water Series PF3W 3-color display Dimensions PF3W704/720/740/711-;-;T Integrated display: With temperature sensor PF3W504/520/540/511-;-;T Remote sensor unit: With temperature sensor 3-Color Display Digital Flow Switch for Water PF3W 11 AA 11 AA A A (mm) A AA Model PF3W704/504-;-;T PF3W720/520-;-;T PF3W740/540-;-;T PF3W711/511-;-;T PF3W721/521-;-;T PF3W721/521-F12-;T PF3W721/521-F14

(Function selection mode) OFF [F99] Reset to default settings 0.0 [F14] Zero cut-off setting Front protective cover (Option) If you use the product by changing the setting, refer to the SMC website (URL http://www.smcworld.com) for more detailed information, or contact SMC.

(Function selection mode) OFF [F99] Reset to default settings 0.0 [F14] Zero cut-off setting If you use the product by changing the setting, refer to the SMC website (URL https://www.smcworld.com) for more detailed information, or contact SMC.

OFF [F99] Reset to default settings 0.0 [F14] Zero cut-off setting If the product is to be used with changed settings, refer to the SMC website (URL https://www.smcworld.com) for more detailed information, or contact SMC. Warning: WARNING indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury.

N/A (normal output) [F98] Output check 1000-split [F11] Display resolution setting OFF [F99] Reset to default settings 0.0 [F14] Zero cut-off setting Piping Warning: WARNING indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury.

UP button ( button) Safety Instructions Zero cut-off setting F14 ISA3-F: [0.0]%, ISA3-G: [6.0]%, ISA3-H: [10.0]% Cut Press this button to change the mode and to set the switch point.

10.5 {1077} 13.8 {1407} Holding force KN {kgf} Be sure to make cylinder selections in accordance with the method given on page 30. 2 Series CLS Mounting Brackets/Part Numbers Rod Boot Materials 125 140 160 Bore size (mm) Max. ambient temperature Nil Material J Foot type Note 1) 60C Nylon tarpaulin CS1-L12 CS1-L14 CS1-L16 100C K Flange type Note 2) Heat resistant tarpaulin CS1-F12 CS1-F14

mm) 8.4 {859} 10.5 {1077} 13.8 {1407} Holding force KN {kgf} Be sure to make cylinder selections in accordance with the method given on page 14. 2 Series CNS Mounting Brackets/Part Numbers Rod Boot Materials 125 140 160 Bore size (mm) Symbol Material Maximum ambient temperature J Foot type Note 1) Nylon tarpaulin CS1-L12 CS1-L14 CS1-L16 60C 100C K Heat resistant tarpaulin CS1-F12 CS1-F14

Model Rated pressure range Smallest settable increment MPa kPa kgf/cm2 bar psi ISE70/70G 0 to 1 MPa 0.001 1 0.01 0.01 0.1 ISE71 0 to 1.6 MPa ISE75G 0 to 2 MPa 0.2 ISE76G 0 to 5 MPa 0.01 0.1 0.1 1 ISE77G 0 to 10 MPa I Zero cut-off setting (F14) When the pressure display value is close to zero, this function forces the display to zero.

Rod Boot Material I Bore size (mm) 125 140 160 Material Max. amhien1 temwaiure Symbo .. '" en 0 Foot" CS2-L12 CS2L14 CS2 l1 6 J l 58 ~ F Nylon tarpaulin Flange CS2 F12 CS2-F14 CS2-F16 Heal resisHlnt tarpaulin K 230 ~ F ' Single clevis CS2-C12 CS2C14 CS2-C16 ' MaKimum ambu~nt lemperalUre lor the rod 0001 {tsell.

make cylinder selections in accordance with the method given on page 9-9-6. 1569 180 200 998 250 813 9-9-9 10 Series CLS Rod Boot Material Mounting Bracket Part No. 125 140 160 180 200 250 Bore size (mm) Max. ambient temperature Symbol Rod boot material J 60C Foot (1) Nylon tarpaulin CS1-L12 CS1-L14 CS1-L16 CS1-L18 CS1-L20 CS1-L25 110C K Flange (2) Heat resistant tarpaulin CS1-F12 CS1-F14

force (KN) 8.4 125 10.5 140 13.8 160 Bore size (mm) Be sure to make cylinder selections in accordance with the method given on page 9-8-6. 9-8-9 10 Series CNS Rod Boot Material Mounting Bracket Part No. 125 140 160 Bore size (mm) Max. ambient temperature Rod boot material Symbol J 70C Foot (1) Nylon tarpaulin CS1-L12 CS1-L14 CS1-L16 110C K Flange (2) Heat resistant tarpaulin CS1-F12 CS1-F14