SMC Corporation of America
Elite Part Number Search
Search Results "NCDY2S25L-2000-A73"

Note 2) These figures show the dimensions when equipped with D-A73 or D-A80 auto switches.

Round type Diamond type D-M9NWV: D-M9PWV: D-M9BWV: M9NWV: M9PWV: M9BWV: R D D-A73: A73: Clamp arm position (viewed from top) D-A79W: A79W: Symbol Clamp arm position Symbol Clamp arm position := Lead wire Auto switches and mounting brackets are shipped together, (but not assembled).

NPN) IC A76H 5V Yes A72H A72 200V Grommet Reed switch Solid state switch A73H A73 100V 12V 5V 12V 100V or less Stroke (mm) No A80H A80 IC Relay, PLC 2 wire Refer to standard stroke on p.2.4-3. Refer to p.2.4-3 when using auto switch.

7 23 A B Hs 11.5 Hs CJ1 8.5 CJP 1 D-A7H D-A80H 7 22 A B Hs 10.2 A 36.7 B 16 D-C73C D-C80C CJ2 Hs CM2 8.5 10 13.3 13.3 CG1 A B 24 D-A73C D-A80C Hs 18.6 16 A 29 B MB D-H7 D-H7W D-H7BAL D-H7NF Hs MB1 CA2 8.5 1 7 23.5 A B D-A79W CS1 Hs 14 16 A 38.2 B D-H7C C76 C85 D-F7 D-F7W D-J79 D-J79W D-F7BAL D-F79F 8.5 23 A B 1 C95 Hs 11 CP95 Auto Switch Mounting Position (mm) D-C7 D-C80 D-C73C D-C80C D-A73

South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com A B 24 D-A73C D-A80C Hs 18.6 16 A 29 B MB D-H7 D-H7W D-H7BAL D-H7NF Hs MB1 CA2 8.5 1 7 23.5 A B D-A79W CS1 Hs 14 16 A 38.2 B D-H7C C76 C85 D-F7 D-F7W D-J79 D-J79W D-F7BAL D-F79F 8.5 23 A B 1 C95 Hs 11 CP95 Auto Switch Mounting Position (mm) D-C7 D-C80 D-C73C D-C80C D-A73

CV/MVG wIf switches with an indicator light such as DA93(V) or D-A73(H, C) are used under a DC load, their polarities must be observed. The brown lead wire is positive (+) and the blue lead wire is negative (). The switches will operate even if the wires are reversed, but their LEDs will not illuminate.

Auto Switch Specifications Grommet Electrical entry: Perpendicular PLC: Programmable Logic Controller D-A7 (With indicator light) Auto switch model Applicable load Load voltage Load current range (3) D-A72 Relay, PLC 200 VAC 5 to 10 mA D-A73 Relay, PLC 24 VDC (4) 100 VAC 5 to 20 mA 5 to 40 mA e None 2.4 V or less Red LED illuminates when turned ON.

Auto switch type Model Features Electrical entry (Direction) Applicable bore size D-A72 D-A73 Grommet (Perpendicular) Without indicator light D-A80 D-A79W Diagnostic indication (2-color indication) Reed D-A73C Connector (Perpendicular) D-A80C Without indicator light D-A72H D-A73H, A76H Grommet (In-line) D-A80H Without indicator light 12 to 100 125 to 160 D-F7NV, F7PV, F7BV D-F7NWV, F7BWV

A72H A73H F79 F7P J79 F79W F7PW J79W F7BA F79F P5DW 200 V A72 A73 A73C A79W F7NV F7PV F7BV J79C F7NWV F7BWV F7BAV Grommet Yes 100 V 12 V Relay, PLC 2-wire 24 V Connector 12 V Diagnostic indication (2-color indication) Grommet 3-wire (NPN) 5 V, 12 V IC circuit 3-wire (PNP) Grommet 2-wire 12 V Connector Relay, PLC Yes 24 V 3-wire (NPN) IC circuit 5 V, 12 V Diagnostic output

Lead Wire Length Lead wire length designation (example) D-A73 L Lead wire length Nil L Z NNote) 0.5m 3m 5m None Note) Applies only to D C type connector switches.

Applicable models: D-A93, A73(H)(C), A79W 1) If connections are reversed on a 2-wire type switch, the auto switch will not be damaged if protected by a protection circuit, but the switch will always stay in an ON state.

D-J51: 5ms or less MHZ2 Lead Wire Length MHZJ2 How to specify lead wire length MHQ (Example) MHL2 L D-A73 MHR Lead wire length 0.5m 3m L 5m Z N MHK MHS None Applicable to only connector type switch D-C MHC2 Note 1) Lead wire length Z: 5m Applicable to Reed switch: D-B53/B54, D-C73 (C)/C80C, D-A73 (C) (H)/A80C MHT2 Solid state switch: Made to order (Except D-F9, F9lV, F7lWV) D-A53/A54, D-Z73

angle projection] (Band mounting type) (Rail Mounting type) D-C7 D-C80 D-A7 D-A80 ( ): In case of D-A72 D-A7H D-A80H D-C73C D-C80C D-H7 D-H7W D-H7BAL D-H7NF D-A73C D-A80C D-H7C D-A79W D-F7 D-F7W D-J79 D-J79W D-F7BAL D-F79F D-J79C Auto Switch Mounting Position (mm) D-A7H/A80H/A72 D-A73C/A80C D-F7/J79 D-F7W/J79W D-J79C/F7BAL D-F79F D-H7 D-H7C D-H7W D-H7BAL D-H7NF D-C7 D-C80 D-C73C D-C80C D-A73

/Mounting Method Applicable cylinder -X2321/-X2322 -X2321/-X2322 -X2321/-X2322 Applicable auto switches D-P3DWAl D-M9lV/M9lWV D-A73/A79W Bore size [mm] 32 32 32 Auto switch mounting bracket part no.

Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com D-H7 D-H7W D-H7BAL D-H7NF D-A73C D-A80C D-H7C D-A79W D-F7 D-F7W D-J79 D-J79W D-F7BAL D-F79F D-J79C Auto Switch Mounting Position (mm) D-A7H/A80H/A72 D-A73C/A80C D-F7/J79 D-F7W/J79W D-J79C/F7BAL D-F79F D-H7 D-H7C D-H7W D-H7BAL D-H7NF D-C7 D-C80 D-C73C D-C80C D-A73

Magnetically coupled cylinders save space and have a wide range of applications. The NCY series can be used in many diverse environments, because there is no external leakage. The use of a linear guide makes loading and moments, directly on the cylinder possible. T-Slots on the mounting surfaces provides mounting freedom, and a variety of guides can be used to achieve the necessary accuracy

Magnetically coupled cylinders save space and have a wide range of applications. The NCY series can be used in many diverse environments, because there is no external leakage. The use of a linear guide makes loading and moments, directly on the cylinder possible. T-Slots on the mounting surfaces provides mounting freedom, and a variety of guides can be used to achieve the necessary accuracy

Magnetically coupled cylinders save space and have a wide range of applications. The NCY series can be used in many diverse environments, because there is no external leakage. The use of a linear guide makes loading and moments, directly on the cylinder possible. T-Slots on the mounting surfaces provides mounting freedom, and a variety of guides can be used to achieve the necessary accuracy

Magnetically coupled cylinders save space and have a wide range of applications. The NCY series can be used in many diverse environments, because there is no external leakage. The use of a linear guide makes loading and moments, directly on the cylinder possible. T-Slots on the mounting surfaces provides mounting freedom, and a variety of guides can be used to achieve the necessary accuracy

Lead wire length (m) Load voltage Rail mounting Indicator light Wiring (Output) Special function Type Electrical entry Pre-wired connector Applicable load 0.5 (Nil) 3 (L) 5 (Z) None (N) AC Perpendicular In-line DC IC circuit 3-wire (NPN equivalent) A76H 5 V Reed switch Solid state switch Grommet A72H A73H F79 F7P J79 F79W F7PW J79W F7BA F79F A72 A73 A73C A79W F7NV F7PV F7B J79C F7NWV