(Where the load voltage is 110 VAC) When the load voltage is increased by more than 10% to the rating of applicable auto switches (except D-A73C/A80C/C73C/C80C/ 90/97/ A79W) above, use a contact protection box (CD-P11) to reduce the upper limit of the load current by 10% so that it can be set within the load current range, 110 VAC.
C73C 5mZ EX.) C73CZ 3m L C73CL N C73CN In addition to the models in the above table, there are some other auto switches that are applicable. For more information, refer to page 2. 1 Series CBJ2 Specifications Series CJ2 air cylinder is equipped with end lock function.
Lead wire length symbols: 0.5 mNil 3 m L 5 m Z None N (Example) C73C (Example) C73CL (Example) C73CZ (Example) C73CN Since there are other applicable auto switches than listed, refer to page 10-15-6 for details.
Solid state auto switch : D-H7, D-H7C, D-H7W, D-H7NF, D-H7BA Reed auto switch : D-C7, D-C80, D-C73C, D-C80C, D-A80, D-A9, D-A9V, D-A79W, D-A73 CM2 series C port Stroke A Stroke B A port B port (mm) Bore size (mm) SA SB ZZ 20 48 62 164 25 48 62 168 32 50 64 172 SA + Stroke A SB + Stroke B 40 67.5 88.5 222 ZZ + Stroke (A + B) CM2R series A port B port C port (mm) Bore size (mm) SA SB ZZ 20
Applicable models: D-A73/A73H/A73C/C73/C73C/E73A/Z73/R73 D-97/93A/A93/A93V D-A33/A34/A33A/A34A/A44/A44A D-A53/A54/B53/B54 2) However, when using a two color indication auto switch, the switch (D-A79W/A59W/B59W), be aware that the switch will constantly remain ON if the connections are reversed.
(Example) C73C (Example) C73CL (Example) C73CZ (Example) C73CN Since there are other applicable auto switches than listed, refer to page 10-15-12 for details.
(Example) C73C (Example) C73CL (Example) C73CZ (Example) C73CN Data Since there are other applicable auto switches than listed, refer to Best Pneumatics Vol. 6 for details.
Applicable models: D-A73/A73H/A73C/C73/C73C/E73A/Z73/R73 D-97/93A/A93/A93V D-A33/A34/A33A/A34A/A44/A44A D-A53/A54/B53/B54 2) However, when using a two color indication auto switch, the switch (D-A79W/A59W/B59W), be aware that the switch will constantly remain ON if the connections are reversed.
C73C 5mZ e.g.) C73CZ 3mL C73CL NoneN C73CN Solid state switches marked with are manufactured upon receipt of order. 1.3-52 Low Friction Style: Double Acting Single Rod Series CJ2Q Application Example Specially designed to keep friction of the piston to a minimum. Suitable for contact-pressure control requiring smooth operation at low pressures.
Applicable models D-A73, A73H, A73C, C73, C73C, E73A, Z73, R73 D-97, 93A, A93, A93V D-A33, A34, A33A, A34A, A44, A44A D-A53, A54, B53, B54 2) However, when using a 2 color indication auto switch (DA79W, A59W, B59W), be aware that the switch will constantly remain ON if the connections are reversed.
For detailed specifications, please contact SMC. 100 V Relay, PLC Yes 100 V, 200 V 12 V 24 V (B54) B54 B73C 2-wire 12 V C73C B59W H7A1 H7A2 H7B H7C H7NW H7PW H7BW H7BA H7NF PLC Grommet G79 (B59W) Diagnostic indication (2-color indication) IC circuit 3-wire (NPN) 3-wire (PNP) 5 V, 12 V K79 Grommet 2-wire 12 V K79C Connector Relay, PLC Yes 24 V IC circuit 3-wire (NPN) 3-wire (PNP)
Lead wire length symbols: 0.5 m Nil(Example) C73C 1 m L (Example) C73CL 5 m Z (Example) C73CZ None N (Example) C73CN Since there are other applicable auto switches than listed, refer to page 9-2-16 for details. For details about auto switches with pre-wire connector, refer to page 9-15-66. 9-2-10
(Example) C73C (Example) H73CL (Example) C73CZ (Example) C73CN Lead wire length symbols: 0.5 m 3 m 5 m None Nil L Z N Since there are other applicable auto switches than listed, refer to page 9-2-29 for details. For details about auto switches with pre-wire connector, refer to page 9-15-66. 9-2-27
Lead wire length symbols: 0.5 m Nil (Example) C73C 3 m L (Example) C73CL 5 m Z (Example) C73CZ None N (Example) C73CN Since there are other applicable auto switches than listed, refer to page 9-5-22 for details.
Lead wire length symbols: 0.5 mNil 3 m L 5 m Z None N (Example) C73C (Example) C73CL (Example) C73CZ (Example) C73CN Since there are other applicable auto switches than listed, refer to page 10-15-12 for details. For details about auto switches with pre-wire connector, refer to page 10-20-66. 10-15-10
Lead wire length (m) Load voltage Indicator light Auto switch model Wiring (Output) Special function Type Electrical entry Applicable load Pre-wire connector Rail mounting Band mounting 0.5 (Nil) 3 (L) 5 (Z) None (N) AC DC In-line Perpendicular 3-wire (NPN equivalent) 5 V IC circuit C76 A76H Reed switch Solid state switch Grommet 200 V 100 V 12 V 12 V C73 C73C H7A1 H7A2 H7B H7C H7NW
NPN) C76 5 V IC Reed switch Solid state switch Grommet B54 C73 C73C B59W H7A1 H7A2 H7B H7C H7NW H7PW H7BW H7BA H7NF 100 V, 200 V 100 V 12 V Relay, PLC 2-wire 24 V Connector Diagnostic indication (2-color) Grommet G59 G5P K59 G59W G5PW K59W G5BA G59F 3-wire (NPN) 3-wire (PNP) 5 V, 12 V IC Grommet 2-wire 12 V Connector 3-wire (NPN) 3-wire (PNP) IC Relay, PLC 5 V, 12 V Diagnostic
Nil (Example) C73C 5m . Z (Example) C73CZ 3m .. L C73CL None .
Lead wire length 0.5 m Nil (Example) C73C 3 m L (Example) C73CL 5 m Z (Example) C73CZ None N (Example) C73CN In addition to the models in the above table, there are some other auto switches that are applicable.
C76 5V IC circuit Yes B53 PLC B54 12V Reed switch Solid state switch 200V or less Grommet B64 No 12V C73 Yes 100V 2 wire 24V Relay, PLC 5V, 12V C80 No IC circuit 100V or less 12V C73C Yes Connector 5V, 12V C80C No IC circuit 24V or less Diagnostic indication (2 color indicator) Grommet B59W Yes 3 wire (NPN) H7A1 G59 IC circuit 5V, 12V 3 wire (PNP) H7A2 G5P Grommet H7B K59 2 wire 12V