Yes A90V Grommet IC circuit 100 V or less No Yes No Yes No 100 V, 200 V Relay PLC 200 V or less 12 V Connector 2-wire 24 V IC circuit 24 V or less PLC Terminal conduit 100 V, 200 V Yes Relay PLC DIN terminal Grommet Diagnostic indication (2-color indicator) 1 Water resistant type auto switches can be mounted on the above models, but in such case SMC cannot guarantee water resistance

CD-P11 CD-P12 Load voltage 24 VDC 100 VAC or less 200 VAC Note) Hysteresis may fluctuate due to the operating environment. Please contact SMC if hysteresis causes an operational problem.

. + = 4 . 1 = a V V 2 V m M E k 2 Ek: Kinetic energy (J) M : Mass of object being transported (kg) m : Mass of moving parts of cylinder (kg) V: Maximum speed (m/s) Va: Average speed (m/s) Mass of moving parts of cylinder (kg) Bore size Standard stroke (mm) (mm) model 20 25 30 40 50 75 100 125 150 175 200 250 300 350 MLGPM20 0.40 0.42 0.45 0.47 0.59 0.65 0.71 0.77 0.83 0.89 1.08 1.20 1.31

Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ Since there are other applicable auto switches than listed, refer to page 26 for details. For details about auto switches with pre-wired connector, refer to pages 1784 and 1785 of Best Pneumatics No. 3.

Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ For details about auto switches with pre-wired connector, refer to the WEB catalog or Best Pneumatics. Auto switches are shipped together, (but not assembled).

Lead wire length symbols: 0.5 mNil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ None N (Example) J79CN Besides the models in the above catalog, there are some other auto switches that are applicable. For more information, refer to page 803. Refer to pages 1328 and 1329 for the details of auto switches with a pre-wired connector.

Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ Refer to page 1114 for applicable auto switches other than listed above. Refer to pages 1328 and 1329 for the details of auto switches with a pre-wired connector.

MGQ 12, 16 M L 10, 20, 30, 40, 50, 75, 100 20, 30, 40, 50, 75, 100 125, 150, 175, 200 M L MGQ 20, 25 MGJ MGQ 32, 40 50, 63 80, 100 25, 50, 75, 100, 125 150, 175, 200 M L MGP MGQ OUT(N) IN(N) Theoretical Output (N) Bore size (mm) MGG Operating pressure (MPa) Rod size (mm) Piston area (mm2) Operating direction 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 MGC Made to Order Specifications (For details

-X1247 75, 100, 125, 150, 175 200, 250, 300 350, 400, 450, 500 600, 700, 800 20, 25 32, 40, 50 63, 80 75, 100, 125, 150, 175 200, 250, 300 350, 400, 450, 500, 600 700, 800, 900,1000 Intermediate strokes and strokes shorter than 75 mm are also available.

Table 1 Manufacturability Check List by Mounting Type and Port Position Yes 100 V No Yes No Yes 100 V or less IC circuit Mounting bracket B LA CB TA FY FZ 12 V Grommet Relay PLC 2-wire Port position 24 V 100 V, 200 V A64 200 V or less Nil A B C D E A59W Diagnostic output (2-color indicator) Water resistant type auto switches can be mounted on the above models, but in such case SMC cannot

V Yes Grommet 100 V 100 V or less 24 V or less Relay, PLC 2-wire 12 V IC circuit Yes No 24V Connector IC circuit No Yes Diagnostic indication (2-color indication) Grommet (Example) M9NW (Example) M9NWM (Example) M9NWL (Example) M9NWZ (Example) H7CN Nil M L Z N Since there are other applicable auto switches than listed, refer to page 123 for details.

Also, when exceeding the air cushion stroke ranges on page 1211, the piston speed should be 100 to 200 mm/s. Note 2) The piston speed is 100 to 1000 mm/s for centralized piping. Note 3) Use at a speed within the absorption capacity range. Refer to page 1211.

Also, when exceeding the air cushion stroke ranges on page 1346, the piston speed should be 100 to 200 mm per second. Note 2) The piston speed is 100 to 1000 mm/s for centralized piping. Note 3) Use at a speed within the absorption capacity range. Refer to page 1346.

Bore size (mm) Standard stroke (mm) Maximum manufacturable stroke (mm) 10 15, 30, 45, 60, 75, 100, 125, 150 400 16 15, 30, 45, 60, 75, 100, 125, 150, 175, 200 400 Symbol Specications -XAl Change of rod end shape -XC3 Special port location -XC9 Adjustable stroke cylinder/Adjustable retraction type Note 1) Manufacture of intermediate strokes at 1 mm intervals is possible.

Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ Since there are other applicable auto switches than listed, refer to page 249 for details. For details about auto switches with pre-wired connector, refer to pages 1784 and 1785.

V Yes Grommet 12 V 5 V, 12 V IC circuit Water resistant (2-color indication) 12 V 5 V 12 V Magnetic field resistant (2-color indication) 2-wire (Non-polar) 3-wire (NPN equivalent) IC circuit IC circuit 100 V Grommet Relay, PLC Yes 2-wire 24 V 5 V, 12 V No 100 V or less Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ

Note 5) Be sure to install a speed controller to the cylinder, and adjust the cylinder speed to make it within the range from 50 to 200 mm/s. To adjust the speed, start with the needle in the completely closed position, and then adjust it by opening gradually.

Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ The auto switch is shipped together, but not assembled.

Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 5 m Z (Example) M9NWZ None N (Example) H7CN 3 m L (Example) M9NWL Since there are other applicable auto switches than listed above, refer to page 14 for details. For details about auto switches with pre-wired connector, refer to the WEB catalog or Best Pneumatics No. 3.