XB6 Heat resistant cylinder Symbol 2 Cold Resistant Cylinder (40 to 70C) -XB7 Air cylinder which changed the seal material and grease, so that it could be used even at lower temperature down to 40C.
The base oil of grease in the cylinder may seep out of the tube, cover, crimped part or rod bushing depending on the operating conditions (ambient temperature 40C or more, pressurized condition, low frequency operation). 7.
Pour in 5 to 40C water and measure the flow rate with a pressure difference of 0.075 MPa. There are cases in which the pressure difference may need to be set higher in order to keep the Reynolds number in the range above 4 x 104 . Substitute the measurement results into the formula (8) to calculate Av.
VXK VXD VXD (4) Test method Connect the equipment for the test to the test circuit shown in Fig. (3), and run water at 5 to 40C. Then, measure the flow rate with a pressure difference where vaporization does not occur in a turbulent flow (pressure difference of 0.035 MPa to 0.075 MPa when the inlet pressure is within 0.15 MPa to 0.6 MPa).
VXK VXD (4) Test method Connect the equipment for the test to the test circuit shown in Fig. (3), and run water at 5 to 40C. Then, measure the flow rate with a pressure difference where vaporization does not occur in a turbulent flow (pressure difference of 0.035 MPa to 0.075 MPa when the inlet pressure is within 0.15 MPa to 0.6 MPa).
(When using AF + AFM) This may be approximately 3000 hours with ultra-dry air (dew point 40C or equivalent). VEX SRH SRP Option SRF Part no.
Grease Grease-free R Clockwise L Counterclockwise Body material A2017 Weight (g) 12.5 49 114 206 310 * Air purification rating: JIS B 8392-1 (ISO8573-1) Quality Degree 4, 4, 2 or more Low profile cyclone type 2A 3A Outer body diameter (mm) 20 25 Piping port size 1.6 Fluid Air* XT661 X260 2A R Operating pressure 0.01 to 0.5 MPa Proof pressure 0.75 MPa Ambient and operating temperature 5 to 40C
FR one-touch fittings: Series KR-W2 Metal one-touch fittings: Series KQB2 Applicable fittings At 20C 0.8 MPa Max. operating pressure At 40C 0.65 MPa How to measure the minimum bending radius At 60C 0.5 MPa Burst pressure Refer to the burst pressure characteristics curve.
-16E KK2S-23E -04E -06E KK3S-04E -06E -08E -10E KK4S-06E -08E -10E -12E KK6S-12E -16E 3.2 4 6 4 6 8 10 6 8 10 12 12 16 3.2 4 6 4 6 8 10 6 8 10 12 12 16 M5 M5 1/8 1/8 1/4 1/4 1/2 1/2 166 S Couplers Series KK Specifications K M Fluid Air, Water KK2: 100 kPa to 1 MPa KK3: 90 kPa to 1 MPa KK4/6: 0 to 1 MPa H Operating pressure range Note) KK Proof pressure 1.5 MPa Air: 5 to 60C Water: 5 to 40C
Air Cooled Aftercooler Series HAA HAA HAW Series HAA can cool high temperature compressed air from compressors down to 40C or less and efficiently remove moisture from the air. The air cooled aftercooler does not require cooling equipment and is free from concerns such as water supply cut-off or freezing. Maintenance is easy and the running cost is reasonable.
1 Air Cooled Aftercooler Series HAA Model/Standard Specifications Series HAA can cool high temperature compressed air from compressors down to 40C or less and efficiently remove moisture from the air. The air-cooled aftercooler does not require cooling equipment and is free from concerns such as water supply cut-off or freezing. Maintenance is easy and the running cost is reasonable.
1 Water Cooled Aftercooler Series HAW Model/Standard Specifications Series HAW can cool high temperature compressed air from compressors down to 40C or less and efficiently remove moisture from the air. As series HAW is watercooled, it can be used where there is high temperature, high moisture and heavy foreign particles.
Valve open Valve open IDFS6E to 11E IDUS3E to 6E Use the air dryer with an ambient temperature lower than 40C. When installing air piping at the air inlet/outlet of air dryer, the IN/OUT port's fitting of air dryer must be held firmly in place with a wrench. Variation of operating conditions may cause condensate to form on the surface of the outlet piping.
Long stroke, Non-rotating rod Series CUK Double acting Single rod 39 With air cushion Series CU-A With air cushion Series CU-A 20, 25, 32 Double acting Single rod 46 For vacuum Series ZCUK For vacuum Series ZCUK 10, 16, 20, 25, 32 Double acting Single rod 55 Related Products Made to Order P . 4, 23, 37 Copper/Fluorine-free: Series 20-XB6 : Heat resistant (150C) -XB7 : Cold resistant (-40C
Bore Size: 12mm, Port Thread Type: M Thread (ø6-ø16); Rc (ø20-ø25), Adjuster Position Set: L (Left Side), Stroke: 40mm, Adjuster: J (Both Sides Adjusters/Shock Absorbers RJ)
Bore Size: 12mm, Port Thread Type: M Thread (ø6-ø16); Rc (ø20-ø25), Adjuster Position Set: L (Left Side), Stroke: 100mm
Bore Size: 12mm, Port Thread Type: M Thread (ø6-ø16); Rc (ø20-ø25), Adjuster Position Set: L (Left Side), Stroke: 40mm
Bore Size: 12mm, Port Thread Type: M Thread (ø6-ø16); Rc (ø20-ø25), Adjuster Position Set: L (Left Side), Stroke: 40mm, Adjuster: A (Both Sides Adjusters/Rubber Stoppers)
Bore Size: 12mm, Port Thread Type: M Thread (ø6-ø16); Rc (ø20-ø25), Adjuster Position Set: L (Left Side), Stroke: 50mm
Bore Size: 12mm, Port Thread Type: M Thread (ø6-ø16); Rc (ø20-ø25), Adjuster Position Set: L (Left Side), Stroke: 50mm, Adjuster: A (Both Sides Adjusters/Rubber Stoppers)