) KF (NW), K (DN) Main material Note 2) Body: aluminum alloy, Main part: SUS304 and FKM (standard sealant material) Surface treatment for body Outside: hard anodized Inside: basis material Actuation pressure MPa(G) 0.4 to 0.7 Air consumption cm3 Note 3) for 0.5MPa 31 61 220 390 680 1420 Solenoid valve SYJ319 SYJ519 Port size M5: Port1(P), 3(R) Rc1/8: Port1(P), M5: Port3(R) Weight kg 0.34
oC 5 to 60 (5 to 150 for high temperature type) Operating pressure Pa(abs) Atmospheric pressure to 1 x 10-5 Conductance l/s Note 1) 5 14 45 80 160 200 Internal 1.3 x 10-10 for the standard material (FKM) at ambient temperatures , excluding gas permeation Leakage Pam3/s External 1.3 x 10-10 for the standard material (FKM) at ambient temperatures , excluding gas permeation Flange type KF (NW
100, 125, 160, 200, 250, 320, 400, 500 2000 50 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600 2000 63 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600 2000 80 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600, 700, 800 2000 100 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600, 700, 800 2000 Ordering Example of Cylinder Assembly Cylinder model: CP96NDD50-100C-NW-M9BW
Normally closed (Pressurize to open, Spring seal) Fluid Inert gas under vacuum Operating temperature (C) 5 to 60 (High-temperature type: 5 to 150) Atmospheric pressure to 1 x 10-6 Operating pressure (Pa) (abs) Conductance (L/s) Note 1) 5 14 45 80 Internal 1.3 x 10-10 at normal temperatures (in case of standard material, FKM), excluding gas permeation Leakage (Pam3/s) External Flange type KF (NW
The MB series medium duty tie rod cylinder offers an improved design that enhances cylinder operation and ease of use. The standard air cushion utilizes a floating cushion seal to eliminate piston rod bouncing. The cushion volume has been elevated permitting about 30% more allowable kinetic energy absorption. The port and captive cushion adjustment valve are located on the same side of cap
The MB series medium duty tie rod cylinder offers an improved design that enhances cylinder operation and ease of use. The standard air cushion utilizes a floating cushion seal to eliminate piston rod bouncing. The cushion volume has been elevated permitting about 30% more allowable kinetic energy absorption. The port and captive cushion adjustment valve are located on the same side of cap
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, "CYL, MB, TIE ROD CYLINDER, N lb
Magnet: None, Mounting: D (Double Clevis), Bore: 80mm, Port Thread: Rc, Stroke: 150mm, Cushion: Rod Boot None; Air Cushion on Both Sides, Pivot Bracket: N (Pivot Bracket)
Magnet: None, Mounting: D (Double Clevis), Bore: 80mm, Port Thread: Rc, Stroke: 700mm, Cushion: Rod Boot None; Air Cushion on Both Sides, Pivot Bracket: No Bracket, Rod End: W (Double Knuckle Joint)
Magnet: None, Mounting: D (Double Clevis), Bore: 80mm, Port Thread: Rc, Stroke: 200mm, Cushion: Rod Boot None; Air Cushion on Both Sides, Pivot Bracket: N (Pivot Bracket)
Magnet: None, Mounting: D (Double Clevis), Bore: 80mm, Port Thread: Rc, Stroke: 200mm, Cushion: Rod Boot None; Air Cushion on Both Sides, Pivot Bracket: No Bracket, Rod End: W (Double Knuckle Joint)
Magnet: None, Mounting: D (Double Clevis), Bore: 80mm, Port Thread: Rc, Stroke: 50mm, Cushion: Rod Boot None; Air Cushion on Both Sides, Pivot Bracket: No Bracket, Rod End: W (Double Knuckle Joint)
Magnet: None, Mounting: D (Double Clevis), Bore: 80mm, Port Thread: Rc, Stroke: 50mm, Cushion: N (w/o Air Cushion), Pivot Bracket: No Bracket, Rod End: W (Double Knuckle Joint)
Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: -, Valves: -, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Without magnet, Port thread type: Rc, Auto
Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: -, Valves: -, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Without magnet, Port thread type: Rc, Auto Switches
Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: -, Valves: -, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Without magnet, Port thread type: Rc, Auto Switches
Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: -, Valves: -, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Without magnet, Port thread type: Rc, Auto Switches
Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: -, Valves: -, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Without magnet, Port thread type: Rc, Auto Switches
Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 600, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: -, Valves: -, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Without magnet, Port thread type: Rc, Auto Switches
Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 600, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: -, Valves: -, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Without magnet, Port thread type: Rc, Auto Switches