U0 U1 U2 U3 U0 U1 U2 U3 S0 S1 S2 S3 S0 S1 S2 S3 (2) Max. 16 stations (2) Max. 16 stations (2) With cable (1.5 m) With cable (3 m) With cable (5 m) With cable (1.5 m) With cable (3 m) With cable (5 m) With cable (1.5 m) With cable (3 m) With cable (5 m) Max. 16 stations Kit P Kit P Kit J Kit J Kit F Kit F L S The valve is equipped with an indicator light/surge voltage suppressor, and the
Do not scratch or put foreign matter on the O-ring, as this will cause air leakage. 1.2-153 SY3000/5000 Base Mounted Type Manifold Stacking Type/DIN Rail Mount Serial Transmission (Integrated) Type45S How to Order Manifolds How to Order Manifold Assemblies (Example) -Q U 3 N 45S SS5Y 05 C6 Manifold series 3 SY3000 5 SY5000 SI unit type Symbol Specification Without SI unit MELSECNET/MINI-S3
Port P Port R2 Unit mounting position IP65 available Kit T1 With terminal blocks 1 to 12 stations D side U side Without SI unit With general purpose type SI unit Mitsubishi: MELSECNET/MINI-S3 data link system Mitsubishi: MELSECNET/MINI-S3 data link system (2 power supply systems) OMRON: SYSBUS wire system Sharp: Satellite I/O link system NKE: Simplified wiring (16 point output) Sanks: S-LINK
100 25 LECSA -S1 S3 200 32 LECSA -S3 S4 400 40 LECSA2-S4 Motor option Stroke [mm] 100 25 LECSB -S5 LECSC -S5 LECSS -S5 Motor mounting position S6 Nil Without option B With lock 100 100 to to 1000 1000 Refer to the applicable stroke table.
Magnet: None, Mounting: G (Head Flange), Bore Size: 32mm, Stroke: 300mm, Rod End Thread: G (Long Male Rod End)
Magnet: D (Built-in), Mounting: F (Rod Flange), Bore Size: 40mm, Stroke: 300mm, Rod End Thread: G (Long Male Rod End)
Magnet: D (Built-in), Mounting: L (Foot), Bore Size: 40mm, Stroke: 300mm, Rod End Thread: G (Long Male Rod End)
Magnet: D (Built-in), Mounting: B (Basic), Bore Size: 20mm, Stroke: 300mm, Rod End Thread: G (Long Male Rod End)
Magnet: None, Mounting: Head Flange, Bore Size: 32mm, Stroke: 300mm, Rod End Thread: Long Male Rod End, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Auto Switch Mounting Bracket: -
Magnet: Built-in, Mounting: Rod Flange, Bore Size: 40mm, Stroke: 300mm, Rod End Thread: Long Male Rod End, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Auto Switch Mounting Bracket: -
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 0.7, Specification: Built-in magnet, Support bracket: Without auto switch mounting bracket
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 0.7, Specification: Built-in magnet, Support bracket: Without auto switch mounting bracket
Size: 25, Motor Mounting Position: Top, Motor: A [Servo Motor (24 VDC)], Lead Screw: B (Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm), Stroke: 300mm, Motor Option: None, Rod End Thread: Female, Mounting: G (Head Flange)
Size: 25, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: B (Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm), Stroke: 300mm, Motor Option: None, Rod End Thread: Female, Mounting: G (Head Flange)
Size: 25, Motor Mounting Position: Top, Motor: A [Servo Motor (24 VDC)], Lead Screw: Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm, Stroke: 300mm, Motor Option: None, Rod End Thread: Female, Mounting: Head Flange, Actuator Cable: -, Actuator Cable Length: -, Controller Type - LEC, JXC: -, I/O Cable Length for LEC: -, Controller Mounting: -, Communication Plug Connector or I/O Cable Length for
Size: 25, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm, Stroke: 300mm, Motor Option: None, Rod End Thread: Female, Mounting: Head Flange, Actuator Cable: -, Actuator Cable Length: -, Controller Type - LEC, JXC: -, I/O Cable Length for LEC: -, Controller Mounting: -, Communication Plug Connector or I/O Cable Length
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 0.7, Specification: Built-in magnet, Support bracket: Without auto switch mounting bracket
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 0.7, Specification: Built-in magnet, Support bracket: Without auto switch mounting bracket
(STO switch) S2: Start switch (STO release switch) S3: On switch S4: Off switch KM1: Magnetic contactor K3: Safety relay EMG: Emergency stop switch CN3 EM1 or EM2 M Servo motor Note.
P1 LED lever meter Sensor S1 S3 Red is on: Output OFF Green is on: Output ON S4 S2 + P2 Red 1 Gap too big S1, S2: Fixed orifice S3: Variable orifice (Set via adjustment knob) S4: Detection nozzle Red 2 Green 1 BEST POSITION The bridge circuit is constructed as shown in the diagram. Position the work piece in front of the nozzle (S4).