Search Results "LEY16AC-100C"

High purity chemical valve, single type, Threaded ports, air operated type, Operating pressure: 0.3 ~ 0.5 MPa, Fluid temperature: 0 to 100C, Port sizes: 1/8, 1/4, 3/8, 1/2, 3/4, 1, "FLUOROPOLYMER, VALVE, FLUOROPOLYMER VALVES and REG, 2I, FLUOROPOLYMER, N lb

High purity chemical valve, 3 port, Operating pressure: 0 ~ 0.5 MPa , Fluid temperature: 0 to 100C , Port sizes: 1/4, Threads: Rc, NPT, FLUOROPOLYMER, VALVE, VALVE, FLUOROPOLYMER VALVES and REG, 2I, FLUOROPOLYMER, 0.43614 lb

High purity chemical valve, single type, Threaded ports, air operated type, Operating pressure: 0.3 ~ 0.5 MPa, Fluid temperature: 0 to 100C, Port sizes: 1/8, 1/4, 3/8, 1/2, 3/4, 1, FLUOROPOLYMER, VALVE, VALVE, FLUOROPOLYMER VALVES and REG, 2I, FLUOROPOLYMER, 2.11643 lb

High purity chemical valve, single type, Threaded ports, air operated type, Operating pressure: 0.3 ~ 0.5 MPa, Fluid temperature: 0 to 100C, Port sizes: 1/8, 1/4, 3/8, 1/2, 3/4, 1, FLUOROPOLYMER, VALVE, VALVE, FLUOROPOLYMER VALVES and REG, 2I, FLUOROPOLYMER, 1.74696 lb

This is a legacy product, and replaced byCP96SDB50-100C, CYL, PROFILE, ISO, ACTUATOR, C95/C96 TIE-ROD CYLINDER, NE, 50MM C95/CP95 DBL-ACT AUTO-SW, 4.42688 lb

A.7A0: Heat Sink Overheated (Detected when the heat sink temperature exceeds 100C.) Check the accumulated load ratio (Un009) to see the load during operation, and the regenerative load ratio (Un00A) to see the regenerative energy processing capacity. Excessive load or operation beyond the regenerative energy processing capacity. Reconsider the load and operating conditions.

A.7A0: Heat Sink Overheated (Detected when the heat sink temperature exceeds 100C.) Check the accumulated load ratio (Un009) to see the load during operation, and the regenerative load ratio (Un00A) to see the regenerative energy processing capacity. Excessive load or operation beyond the regenerative energy processing capacity. Reconsider the load and operating conditions.

This is a legacy product, and replaced byC96SB40-100C, CYL, TIE ROD, ISO, ACTUATOR, C95/C96 TIE-ROD CYLINDER, MD, 40MM C95/CP95 DOUBLE-ACTING, 2.57206 lb

This is a legacy product, and replaced byC96SDB32-100C, CYL, TIE ROD, ISO, AUTO-SW, ACTUATOR, C95/C96 TIE-ROD CYLINDER, LE, 32MM C95/CP95 DBL-ACT AUTO-SW, 1.80779 lb

This is a legacy product, and replaced byC96SDB50-100C, CYL, TIE ROD, ISO, AUTO-SW, ACTUATOR, C95/C96 TIE-ROD CYLINDER, NE, 50MM C95/CP95 DBL-ACT AUTO-SW, 4.18878 lb

Action Opening/Closing stroke (mm) L2L1 Max. operating frequency (c.p.m) Mass (g) Symbol Specifications/Description MHT External grip: 14 Internal grip : 16 External grip: 27 Internal grip : 30 External grip: 45 Internal grip : 53 External grip: 79 Internal grip : 90 -X4 -X5 -X7 -X12 -X39 -X41 -X50 -X53 -X63 -X64 -X65 -X77A -X77B -X78A -X78B -X79 MHKL2-12D 12 11 9 20 104 Heat resistance (100C

Action Opening/Closing stroke (mm) L2L1 Max. operating frequency (c.p.m) Mass (g) Symbol Specifications/Description MHT External grip: 14 Internal grip : 16 External grip: 27 Internal grip : 30 External grip: 45 Internal grip : 53 External grip: 79 Internal grip : 90 -X4 -X5 -X7 -X12 -X39 -X41 -X50 -X53 -X63 -X64 -X65 -X77A -X77B -X78A -X78B -X79 MHKL2-12D 12 11 9 20 104 Heat resistance (100C

MHC MHT Symbol Specifications/Description Heat resistance (100C) Fluororubber seal Without magnet EPDM seal/Fluorine grease Fluorine grease Grease for food -X4 -X5 -X50 -X53 -X63 -X79 MHY MHW -X MRHQ MA D453

MHF Symbol Specifications/Description Heat resistance (100C) Fluororubber seal Without magnet EPDM for seals, Fluorine grease Fluorine grease MHL -X4 -X5 -X50 -X53 -X63 -X79 -X79A -X81A Refer to How to Select the Applicable Model on page 700. Refer to pages 700 and 701 for the details on effective holding force and allowable overhanging distance.

Locking (Maximum Static Load) 125 140 160 Bore size (mm) 8.4 {859} 10.5 {1077} 13.8 {1407} Holding force KN {kgf} Be sure to make cylinder selections in accordance with the method given on page 30. 2 Series CLS Mounting Brackets/Part Numbers Rod Boot Materials 125 140 160 Bore size (mm) Max. ambient temperature Nil Material J Foot type Note 1) 60C Nylon tarpaulin CS1-L12 CS1-L14 CS1-L16 100C

Maximum Static Load) 125 140 160 Bore size (mm) 8.4 {859} 10.5 {1077} 13.8 {1407} Holding force KN {kgf} Be sure to make cylinder selections in accordance with the method given on page 14. 2 Series CNS Mounting Brackets/Part Numbers Rod Boot Materials 125 140 160 Bore size (mm) Symbol Material Maximum ambient temperature J Foot type Note 1) Nylon tarpaulin CS1-L12 CS1-L14 CS1-L16 60C 100C

Applications Applications Drive motor Drive motor Drive motor Drive (Spool) Flexible Coupling Flexible Coupling Drive Body Piping Support Rotary joint Fixed (Body) Direction of rotation Fixed (Adapter plate) Rotary Joint Rotary joint (1 circuit) Flange Air gripper Example of 1 circuit Example of spool drive Example of body drive Made to Order Made to Order Operating temperature 40 to 100C

Heat proof specification "-X4" 2 Grooves on both sides for auto switch "-X41" 4 Cylinder bore X4 F MHK D 1 L 2 MHK 2 L D 1 F Cylinder bore X41 Finger material Dust cover material Type of actuation Finger material Type of actuation Fluoro-rubber seals and special grease for use at high temperatures of up to 212F (100C). Additional switch mounting positions for installation flexibility.

Controller Specifications LC7R-K11A LC7R-K12A Model Heat exchange method based on resistance Regeneration method Regenerative absorption unit 40W Regenerative resistance capacity 380V 180V Regenerative operation voltage Regenerative voltage input mis-wiring protection Over current protection, Overheating protection (Normally closed, Radiator sensor OFF at 100C) To PLC, etc.

Table symbols v : Can be used : Can be used under certain conditions : Cannot be used Compatibility is indicated for fluid temperatures at 100C or less. Consult P/A regarding fluids other than the above. Consult P/A regarding operating conditions. The product is not explosion proof. Please be sure to take measures to guard it from explosive gas when using explosive fluid.