EVS (Pitch) Manual override (Non-locking) VFN M5 x 0.8 (PE port) 4-4.5 Mounting hole 2-Rc 1/8 (1(P) port) (4(A), 2(B) port) 300 (Lead wire length) (Pitch) (5(R1), 3(R2) port) (mm) Stations 2 3 50 40 66 56 20 338 328 L1 L2 4 82 72 5 98 88 6 114 104 7 130 120 8 146 136 9 162 152 10 178 168 11 194 184 12 210 200 13 226 216 14 242 232 15 258 248 16 274 264 17 290 280 18 306 296 19 322 312 3-3
100 200 205 Inch size M5 standard 1/8 standard 1/4 standard 3.2 23 04 06 08 01 03 05 07 09 1/8" 5/32" 3/16" 1/4" 5/16" 4 6 8 Use a 1/8" tube.
Specifications External power supply Q 0.1 A F, H, J1, J2, Q, R1, R2, V EX140-SDN1 DeviceNet, CompoBus/D (OMRON Corp.)
Specifications External power supply Q 0.1 A F, H, J1, J2, Q, R1, R2, V EX140-SDN1 DeviceNet, CompoBus/D (OMRON Corp.)
N.O. 1 2 3 4 5 6 7 8 J 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz 24 VDC 12 VDC 240 VAC 50/60 Hz 48 VAC 50/60 Hz 230 VAC 50/60 Hz 1 2 3 VXD21 VXD22 VXD23 Symbol Nil 2 Valve Symbol Nil 2 Valve N.C. N.O.
Controller USB cable Communication 120.3 120.3 mm mm 200 200 mm/s mm/s (type A to mini-B) cable 100 500 100 500 1 1 200 1000 200 1000 2 2 50 200 50 200 3 3 CN3 PC (PC is prepared by the user.) 20 - 4.4 CN4: Counter connector (option) Connect the controller to the Multi-counter (CEU5) using the counter cable (LATH3-). Refer to section 6.2 Counter plug wiring (P.24).
CompoBus/D compatible EX140-SDN1 Q 0.1A F, H, J1, J2 Q, R1, R2, V Current consumption (within unit) OMRON Corporation: CompoBus/S (16 points) compatible EX140-SCS1 R1 OMRON Corporation: CompoBus/S (8 points) compatible EX140-SCS2 R2 Mistubishi Electric Corporation: CC-Link compatible EX140-SMJ1 V Type SR1/SR2 OMRON Corporation CompoBus/S compatible Type SV Mitsubishi Electric Corporation
VVZS2000-22A-1 VVZS2000-22A-2 VFN G L M KZ D Cylinder side pressure (P2) Check valve Applicable valve model VZS2450-FZ VZS24504(A) 2(B) 3(R2) 5(R1) 3(R2) 5(R1) 3(R2) 5(R1) 100 Ncm3/ min or less Solenoid one side 1(P) de-energized Leakage (Supply pressure: 0.5 MPa 100 Ncm3/ min or less Solenoid both sides de-energized 1(P) Piston SUP side pressure (P1) SUP side pressure P1 (MPa) 0 Operating
R1 1/2 kg 49 68 95 110 Weight Accessories Drain tube123.5m) Drain tube holder, Instruction manual Note 1: The operating range does not guarantee use with normal air flow capacity.
Plug-in type Non plug-in type VVZS3000-22A-1 VVZS3000-22A-2 VFN G L M KZ D Cylinder side pressure Check valve Applicable valve model VZS3450-FZ VZS34504(A) 2(B) 3(R2) 5(R1) 3(R2) 5(R1) 3(R2) 5(R1) 210 Ncm3/ min or less Solenoid one side energized 1(P) 210 Ncm3/ min or less Leakage 0.5 MPa Solenoid both sides energized 1(P) Piston SUP side pressure P1 SUP side pressure P1 (MPa) 0 Operating
Pallet Lock Cylinder W-R1/W-R3 Series How to Order W R1 S2 Type 1 B W R3 S B Type 3 Proximity Switch B With mounting bracket (Without proximity switch) SC With proximity switch * For details, refer to the table below.
Series KK13 Series KK13 Series KK13 Manufactured by RECTUS AG 163 Variations Variations Series KK Series KK 165 to 173 Male thread type Port size Series M5 R1/8 R1/4 R3/8 R1/2 R3/4 KK2 KK3 KK4 KK6 Female thread type Port size M5 Series Rc1/8 Rc1/4 Rc3/8 Rc1/2 KK2 KK3 KK4 KK6 Nut fitting type (for fiber reinforced urethane hose) Applicable hose I.D.
Port size (P, A and B port) Rated voltage M5 M5 x 0.8 01 Rc 1 8 1 2 3 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 110 VAC, 50/60 Hz 220 VAC, 50/60 Hz R1, R2: M5 4 Option 5 6 24 VDC 12 VDC Nil None With bracket (Not assembled) 7 240 VAC, 50/60 Hz 9 Other Option F Option Part No. Description Part no.
Clean Exhaust Filter SFE Series RoHS How to Order SFE 11 Size/Port size Male thread type Plug-in type Symbol Port size Max. ow capacity L/min (ANR) 11 M5 x 0.8 3 42 R1/8 65 52 R1/8 130 53 R1/4 130 73 R1/4 200 Symbol Port size Max. ow capacity L/min (ANR) 3A 4 30 4B 6 65 5C 8 130 7D 10 200 Male thread type One-touch tting type Symbol Applicable tubing O.D.
XMA series with KF (NW) flange A (mm) Model Weight (kg) Conductance (L/s) B (mm) CYV XMA-16 40 103 0.33 5 XMA-25 XMA-40 XMA-50 50 113 0.61 14 B 65 158 1.40 45 70 170 2.00 80 A 160 XMA-63 XMA-80 88 196 3.60 90 235 6.20 200 A : Common to all series. 479 Series Variations Operating pressure Flange size Shaft seal system Models Valve type Angle type In-line type Options Application Switch Indicator
NAR1000 NAW1000 K10 1/8NPT 0 ~ 160PSI NAR2000 2500 NAW2000 3000 K12 1/4NPT 0 ~ 160PSI NAR4000 NAW4000 K13 1/4NPT 0 ~ 30PSI NAR4000 NAW4000 K20 1/8NPT 0 ~ 30PSI NAR2000 2500 NAW2000 3000 G27-10-R1 116 Connection D I M E N S I O N S 5K8-10P/4P/2.5P D I M E N S I O N S 4K8-10P/4P/2.5P D I M E N S I O N S G27-10-R1 VACUUM GAUGES H O W T O O R D E R V A C U U M G A U G E S Scale in mmHg
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 0.30 0.35 0.6 0.7 Outlet pressure MPa Outlet pressure MPa 0.5 0.25 0.4 0.20 0.3 0.15 0.2 0.10 0.1 0.05 0 0.00 0 50 100 150 200 0 50 100 150 200 250 300 Flow rate /min(ANR) Flow rate /min(ANR) Condition: Inlet pressure 0.7MPa Condition: Inlet pressure
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 0.30 0.35 0.6 0.7 Outlet pressure MPa Outlet pressure MPa 0.5 0.25 0.4 0.20 0.3 0.15 0.2 0.10 0.1 0.05 0 0.00 0 50 100 150 200 0 50 100 150 200 250 300 Flow rate /min(ANR) Flow rate /min(ANR) Condition: Inlet pressure 0.7MPa Condition: Inlet pressure
Caution -4- Specifications Model S F E 11 Port size Male thread type Plug-in type One-touch fitting type Max. flow capacity Symbol Port size Symbol Port size Symbol Applicable L/min (ANR) tube O.D. 11 M50.8 3 3A 4 3F 4 30 42 R1/8 4B 6 4G 6 65 52 R1/8 5C 8 5H 8 130 53 R1/4 130 73 R1/4 7D 10 7J 10 200 Accessory (Bracket) S F E B R 3 Symbol Applicable model 3 SFE3 4 SFE4 5 SFE5 6 SFE7
Tightening Torque (Metal type) Applicable tightening torque Nm Connection thread R 3/4 R1 R1 1/4 R1 1/2 R2 Selection 28 to 30 36 to 38 40 to 42 48 to 50 48 to 50 Caution 1. When selecting the silencer, the sonic conductance (including combined sonic conductance) of the silencer should be larger than that of the solenoid valve.