SMC Corporation of America
Elite Part Number Search
Search Results "LEJS63T7B-900-S2"

S1 S2 Effective area ratio 2.3 : 1 Pressure loss: Large K M 3 Without nozzle 3 H Pressure Loss of Air Gun Only Effective area (mm2) Upstream side S1: 15 Nozzle side S2: 6.4 D S1 : S2 = 2.3 : 1 Effective area ratio Nozzle size (mm) Number of nozzles Supply pressure Regulator pressure Outlet pressure Pressure loss 3 MS Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco,

Warning Do not drop, bump or apply excessive impacts (300m/s2 or more for reed auto switches and 1000m/s2 or more for solid state auto switches) while handling. Although the body of the auto switch may not be damaged, the inside of the auto switch could be damaged and cause malfunction. 2. Observe the proper tightening torque for mounting an auto switch.

Standard strokes Standard stroke (mm) Long stroke (mm) Bore size (mm) 350, 400, 450, 500, 600 75, 100, 125, 150, 175 40, 50, 63 700, 800, 900, 1000 200, 250, 300 Intermediate strokes and strokes of less than 75mm can also be manufactured.

Note 4) (ft/s2) 30/150 (9/150ft/s2) Rated voltage 24VDC, 12VDC, 100VAC, 110VAC, 200VAC, 220VAC (50/60Hz) Allowable voltage fluctuation % 10% of rated voltage Coil insulation type Class B Enclosure Note 5) Dust proof (equivalent to IP40) Power consumption W Note 3) 2.5 (VDW10), 3 (VDW20/30) Note 1) Consult SMC when used under conditions which may cause condensation on the exterior of the

Auto Switches Common Specifications Type Reed auto switch Solid state auto switch 1 ms or less 1.2 ms Operating time 300 m/s2 1000 m/s2 Impact resistance 50 M or more at 500 VDC Mega (Between lead wire and case) Insulation resistance 1500 VAC for 1 minute (Between lead wire and case) 1000 VAC for 1 minute (Between lead wire and case) Withstand voltage 10 to 60C Ambient temperature IEC60529

Note 4) (ft/s2) 30/150 (9/150ft/s2) Rated voltage 24VDC, 12VDC, 100VAC, 110VAC, 200VAC, 220VAC (50/60Hz) Allowable voltage fluctuation % 10% of rated voltage Coil insulation type Class B Enclosure Note 5) Dust proof (equivalent to IP40) Power consumption W Note 3) 2.5 (VDW10), 3 (VDW20/30) Note 1) Consult P/A when used under conditions which may cause condensation on the exterior of the

1200 Installation distance [mm] mm At maximum air flow (air flow scale: 4) 300 mm 300 0 4s 6s 8s 0 2s -300 mm -300 0 300 600 900 1200 Installation distance [mm] mm At minimum air flow (air flow scale: 1) 300 mm 300 6s 0 4s 8s 0 2s -300 mm -300 0 300 600 900 1200 Installation distance [mm] mm 18 - Doc. no.

Standard item Sulfuric acid ion (SO42) [mg/L] 200 or less [mg/L] 100 or less Acid consumption amount (at pH4.8) Total hardness [mg/L] 200 or less Calcium hardness (CaCO3) [mg/L] 150 or less Ionic state silica (SiO2) [mg/L] 50 or less Iron (Fe) [mg/L] 1.0 or less Copper (Cu) [mg/L] 0.3 or less Sulfide ion (S2) [mg/L] Should not be detected.

The vacuum aspiration fluence shows the fluence immediately before piping in the actuator. 5 - 3.How to Order 11LEJS 40 A 500 S2 1 10 9 8 7 4 5 3 2 6 *1 (2) Motor type (3) Lead [mm] (1) Size 40 LEJS40 LEJS63 Output [W] Actuator size Compatible controller Type 63 16 A 20 AC servo motor (incremental encoder) S2 10 8 B LECSA-S1 40 100 (5) Motor option AC servo motor (incremental encoder) S3

LEMB / LEMC LEMH / LEMHT Speed [mm/s] Acceleration Speed [mm/s] Acceleration [mm/s2] [mm/s2] 0 48 250 48 250 1 75 500 75 500 2 100 1000 100 1000 3 150 1500 150 1500 4 200 2000 200 2000 5 250 2500 300 2500 6 300 3000 400 3000 7 350 4000 500 4000 8 400 5000 600 5000 9 450 6000 800 6000 10 500 7500 1000 7500 11 600 10 1200 10 12 700 12500 1400 12500 13 800 15000 1600 15000 14 900 17500 1800

A Controller type Motor type Power supply voltage Symbol Type AC servo motor (S2) Capacity Encoder LECSA1-S1 LECSA1-S3 LECSA2-S1 LECSA2-S3 LECSA2-S4 LECSB1-S5 LECSB1-S7 LECSB2-S5 LECSB2-S7 LECSB2-S8 AC servo motor (S2) 100 to 120 VAC 50/60 Hz S1 S3 S4 S5 S7 S8 100 W B Pulse input type (For absolute encoder) AC servo motor (S3) Pulse input type (For incremental encoder) Incremental AC servo

Warning Do not drop, bump or apply excessive impacts (300m/s2 or more for reed auto switches and 1000m/s2 or more for solid state auto switches) while handling. Although the body of the auto switch may not be damaged, the inside of the auto switch could be damaged and cause malfunction. 2. Observe the proper tightening torque for mounting an auto switch.

Start flag 0: no send Numerical data input 1 1: send Data writting RWwn Step data No 0 to 63 Operation Note) 1 1: Absolute 2: Relative H RWwn+1 L Speed 2 0 to 65500 mm/s 3 RWwn+2 2 Position 4 +/-2147483647 0.01mm 1 RWwn+3 0 H RWwn+4 L Acceleration 2 0 to 65500 mm/s2 ID1 Numerical data input H RWwn+5 L Deceleration 2 0 to 65500 mm/s2 Data writting Pushing force 1 0 to 30 10% RWwn+6 Trigger

Avoid using the latching solenoid valves in environment where impacts or collisions (30/150 m/s2 or more) exist. Also, do not use in places where the strong magnetic fields are present. 4. Even though the armature in the solenoid of this valve is held on to B side, ON position (Reset), verify either A side, ON position or B side, ON position by energizing prior to use.

rail type, ACTUATOR, ELECTRIC, ACTUATOR, ELECTRIC ACTUATOR, LC, 32MM LE ELECTRIC ACTUATOR, 10.58218 lb, ModelActuator specificationsElectric specificationsLock unit specificationsStroke [mm] Note 1)Work load [kg] Note 2)Note 3) Max. speed [mm/s]Max. acceleration/deceleration [mm/s2]Positioning repeatability [mm]Lead [mm]Impact/Vibration resistance [m/s2] Note 4)Actuation typeGuide

rail type, ELECTRIC, ACTUATOR, ACTUATOR, ELECTRIC ACTUATOR, IC, 25MM LE ELECTRIC ACTUATOR, 6.63866 lb, ModelActuator specificationsElectric specificationsLock unit specificationsStroke [mm] Note 1)Work load [kg] Note 2)Note 3) Max. speed [mm/s]Max. acceleration/deceleration [mm/s2]Positioning repeatability [mm]Lead [mm]Impact/Vibration resistance [m/s2] Note 4)Actuation typeGuide

rail type, ELECTRIC, ACTUATOR, ACTUATOR, ELECTRIC ACTUATOR, IC, 25MM LE ELECTRIC ACTUATOR, 6.63866 lb, ModelActuator specificationsElectric specificationsLock unit specificationsStroke [mm] Note 1)Work load [kg] Note 2)Note 3) Max. speed [mm/s]Max. acceleration/deceleration [mm/s2]Positioning repeatability [mm]Lead [mm]Impact/Vibration resistance [m/s2] Note 4)Actuation typeGuide

rail type, ACTUATOR, ELECTRIC, ACTUATOR, ELECTRIC ACTUATOR, LC, 32MM LE ELECTRIC ACTUATOR, 11.96007 lb, ModelActuator specificationsElectric specificationsLock unit specificationsStroke [mm] Note 1)Work load [kg] Note 2)Note 3) Max. speed [mm/s]Max. acceleration/deceleration [mm/s2]Positioning repeatability [mm]Lead [mm]Impact/Vibration resistance [m/s2] Note 4)Actuation typeGuide

rail type, ACTUATOR, ELECTRIC, ACTUATOR, ELECTRIC ACTUATOR, 2C, LE ACTUATOR, NO SIZE RATING, .00000 lb, ModelActuator specificationsElectric specificationsLock unit specificationsStroke [mm] Note 1)Work load [kg] Note 2)Note 3) Max. speed [mm/s]Max. acceleration/deceleration [mm/s2]Positioning repeatability [mm]Lead [mm]Impact/Vibration resistance [m/s2] Note 4)Actuation typeGuide

rail type, ACTUATOR, ELECTRIC, ACTUATOR, ELECTRIC ACTUATOR, IC, 25MM LE ELECTRIC ACTUATOR, .00000 lb, ModelActuator specificationsElectric specificationsLock unit specificationsStroke [mm] Note 1)Work load [kg] Note 2)Note 3) Max. speed [mm/s]Max. acceleration/deceleration [mm/s2]Positioning repeatability [mm]Lead [mm]Impact/Vibration resistance [m/s2] Note 4)Actuation typeGuide typeOperating