Do not drop, bump, or apply excessive impacts (300 m/s2 or more for reed switches and 1000 m/s2 or more for solid state switches) while handling. Although the body of the switch may not be damaged, the inside of the switch could be damaged and cause a malfunction. 2. Do not carry a cylinder by the auto switch lead wires. Never carry a cylinder by its lead wires.
to reach to the Speed (Unit: mm/s2) The setting to define the pushing operation or the positioning operation.
(Unit: 1 mm/s2) XX JOG 1 to "Max ACC/DEC" of the basic parameter acceleration Defines the JOG operation deceleration. (Unit: 1 mm/s2) XX JOG 1 to "Max ACC/DEC" of the basic parameter deceleration JOG thrust *1) Defines the torque limit during JOG operation. (Unit: 1%) XX Fixed distance 0.01 to Full stroke *1) Defines the Inching distance.
-0703, S8-1103, F47-0200), SEMATECH (S2-93, S8-95) Note 1) It should have no condensation.
Do not drop, bump or apply excessive impacts (300 m/s2 or more for reed auto switches and 1000 m/s2 or more for solid state auto switches) while handling. Although the body of the auto switch may not be damaged, the inside of the auto switch could be damaged and cause malfunction. 2. Observe the proper tightening torque for mounting an auto switch.
rate: 50% Stroke 300 mm Series MB, CA2 Pressure 0.5 MPa Load rate: 50% Stroke 500 mm Average speed (mm/s) Series 800 700 600 500 400 300 200 100 0 Perpendicular, upward actuation SY3140-01 Horizontal actuation 800 700 600 500 400 300 200 100 0 SY5140-02 800 700 600 500 400 300 200 100 0 SY7140-03 800 700 600 500 400 300 200 100 0 SY9140-04 Cylinder is in extending.
Standard length is 300 mm, but the following lengths are also available.
Standard length is 300 mm, but the following lengths are also available.
wire Note) Be sure to select the power saving circuit type length 300 mm length 300 mm (length 300 mm) when it is continuously energized for long periods of time.
72 64 [65.3] 123 87.8 [90.4] 103.8 [106.4] (Lead wire length) 300 41.6 300 54 [60.5] (Lead wire length) [ ] for AC Other dimensions are the same as the grommet style
cable L: With lead wire (Length 300 mm) M: With lead wire (Length 300 mm) M: Common exhaust for the pilot and main valve + + + D: Push-turn locking slotted type + R port P, E port H: Lead wire length 600 mm Pilot valve exhaust is centralized to main valve.
Non-locking push type Manual override Lubrication Mounting orientation Shock/Vibration resistance (m/s2) (2) Not required Unrestricted 300/50 Dustproof Note 1) Based on dynamic performance test, JIS B 8374-1981.
Body Ported Bore size Series CJ2 Pressure 0.5 MPa Load factor 50% Stroke 60 mm Series CM2 Pressure 0.5 MPa Load factor 50% Stroke 300 mm Series MB/CA1 Pressure 0.5 MPa Load factor 50% Stroke 500 mm Average speed (mm/s) Series 6 10 16 20 25 32 40 40 50 63 80 100 800 700 600 500 400 300 200 100 0 Perpendicular, upward actuation Horizontal actuation VQZ1121-C6 Courtesy of Steven Engineering,
[87.1] (Lead wire length) 300 57.1 [ ] for AC Other dimensions are the same as the grommet
Standard length is 300 mm, but the following lengths are also available.
Up to 300 Up to 300 Up to 300 Up to 300 Up to 300 Up to 300 M12 x 1.75 depth 22 For mounting brackets, refer to Best Pneumatics.
(30 m/s2) Without sensor/switch With sensor Enclosure Vibration resistance Note 1) 66 ft/s2 (20 m/s2) (With switch) Note) Push-locking type only for the latching type Without sensor/switch With sensor 490 ft/s2 (150 m/s2) Impact resistance Note 2) 330 ft/s2 (100 m/s2) (With switch) Note 1) 10 to 500 Hz for 2 hours in each direction of X, Y and Z (During de-energizing) Note 2) 3 times in
in X, Y, Z directions for 2 hrs. each (De-energized) 100 m/s2 in X, Y, Z directions 3 times each (De-energized) 2% F.S.
Lubrication Not required Mounting orientation Unrestricted 300/50 Note 2) Impact/Vibration resistance (m/s2) Note 1) In the case of single type, be certain that pressure within operating pressure range be supplied to supply port, because return pressure is introduced from supply port {1(P)} for activation.