Stroke [mm] 100 to 500 100 to 500 200 to 600 Horizontal 10 20 20 30 40 45 30 50 60 Work load [kg] Note1) Vertical 4 8 15 5 10 20 7 15 30 Up to 400 1500 900 450 1500 1000 500 1500 1000 500 401 to 500 1200 720 360 1500 1000 500 1500 1000 500 501 to 600 900 540 270 1200 1000 500 1500 1000 500 601 to 700 700 420 210 930 620 310 1410 940 470 Speed [mm/s] Note2) Stroke 701 to 800 550 330 160 750
900 200 900 100 900 50 900 8 150 1000 75 1000 300 1000 200 1000 75 1000 9 200 1200 100 1200 400 1200 250 1200 100 1200 10 250 1400 125 1400 500 1400 300 1400 125 1400 11 300 1600 150 1600 600 1600 400 1600 150 1600 12 350 1800 175 1800 700 1800 500 1800 175 1800 13 400 2000 200 2000 800 2000 540 2000 200 2000 14 450 2500 225 2500 900 2500 600 2500 225 2500 15 700 3000 360 3000 1100 3000 750
Motor output [W]/Size [mm] 750/80 Motor type AC servo motor200 VAC Encoder Absolute 22-bit encoderResolution4194304 p/rev Horizontal 135 Power consumption [W] *7 Vertical 150 Horizontal 15 Stnadby power consumption when operating [W] *8 Vertical 45 power [W] *9 Max.1100 Type *10 Non-magnetizing lock specifications 24 VDC Rated voltage [V] Power consumption at at20 [W] *11 Holding force [N
700 30 700 80 700 60 700 6 80 800 40 800 100 800 80 800 7 100 900 50 900 200 900 100 900 8 150 1000 75 1000 300 1000 200 1000 9 200 1200 100 1200 400 1200 250 1200 10 250 1400 125 1400 500 1400 300 1400 11 300 1600 150 1600 600 1600 400 1600 12 350 1800 175 1800 700 1800 500 1800 13 400 2000 200 2000 800 2000 540 2000 14 450 2500 225 2500 900 2500 600 2500 15 700 3000 360 3000 1100 3000 750
required for cartridge replacement Mist Separators are also available for the Modular Range of Air Preparation Products T E C H N I C A L SPECIFICATIONS D I M E N S I O N S M I S T S E P A R AT O R S E R I E S NAM Max Operating Pressure 1MPa / 145PSI Min Operating Pressure 0.05MPa / 8PSI Ambient & Fluid Temp 5~60C / 40~140F Filtration Degree 0.3m Oil Mist Removal 99.9% NAM150 300 NAM250 750
900st 1.5 800st 700st 1 600st st: Stroke (mm) 400st 500st 0.5 100st 200st 300st 0 0 50 100 150 200 250 300 350 400 450 500 550 600 Allowable end load F (N) MGGM 100Stroke 4 (Slide bearing type) 3.5 3 Deflection Y (mm) 1300st 2.5 1200st 1100st 2 1000st 1.5 900st 800st 1 600st 700st st: Stroke (mm) 500st 0.5 400st 100st 200st 300st 0 0 100 50 150 200 250 300 350 400 450 500 550 600 650 700 750
Note 2) When compressor discharge concentration is 30mg/Nm Specifications Models Model AMG150 AMG250 Drain Catch Series AMG Compressed air 1.0MPa Fluid Maximum operating pressure Rated flow rate Note) l/min (ANR) 300 750 Note) 0.05MPa Min. operating pressure Proof pressure The AMG series is installed in air pressure lines to remove water droplets from compressed air.
150 300 SQ2000 0.82 0.65 450 600 750 Cylinder speeds marked with a are controlled by a fixed orifice.
Cylinder Speed Chart Cv factor Metal seal (Rubber seal) Cylinder bore size mm Cylinder speed mm/s Model 40 50 63 80 100 125 140 160 150 300 1.5 (1.7) VQ7-6 450 600 750 150 300 3.2 (3.2) VQ7-8 450 600 750 Pressure 0.5MPa, Load factor 50% Note) Use as a guide for selection, as cylinder speeds will vary depending on the piping equipment.
Mist Separator Series AM Model Specifications Model AM150C AM250C Fluid Compressed air 1.0 MPa 0.05 MPa 1.5 MPa Max.operating pressure Rated flow (L/min (ANR)) 300 750 Min. operating pressure Note 1) Series AM can separate and remove oil mist and remove fine particles such as rust or carbon of 0.3 m or larger.
DMA-625 5 18-18 DMA-750 34-16 DMA-875 78-14 DMA-1000 1-14 DMA-1250 114-12 www.poweraire.com 1-800-526-7661 18 Section II: Cylinders High Temperature Operations Q: I have an application in a high temperature environment. What should I do to avoid complication? A: The control valve powering the cylinder should be mounted as far away from the heat as possible.
MM 1.000 1.375 1.375 Bore Size (in) 500 (5") 600 (6") 800 (8") MP1 Double head clevis style (X) XC + Stroke A UB P + Stroke 2-EE MR (MAX) KK MM B CD (PIN) TH LR CB E WF LF + Stroke Bore Size (in) 500 (5") 600 (6") 800 (8") 1.375 1-14 1.63 2.000 1.530 1.000 8.50 3/4 NPT 5.13 1.31 1.32 3.25 4.25 3.000 1.63 8.25 MM KK A B CB CD E EE LF+ LR MR P+ TH UB WF XC+ 1.000 3/4-16 1.13 1.500 1.280 .750
DMA-625 5 18-18 DMA-750 34-16 DMA-875 78-14 DMA-1000 1-14 DMA-1250 114-12 www.poweraire.com 1-800-526-7661 18 Section II: Cylinders High Temperature Operations Q: I have an application in a high temperature environment. What should I do to avoid complication? A: The control valve powering the cylinder should be mounted as far away from the heat as possible.
.: Uni-wire H System DeviceNet CC-Link Applicable system Protocol Communication specification Output specification Environmental resistance Release 2.0 Ver. 1.10 Version Note 1) 156 k/625 kbps 2.5 M/5 M/10 Mbps 750 kbps 28.5 kbps Communication speed 125 k/250 k/500 kbps 28.5 kbps 29.4 kbps Specified file Note 2) EDS file 32/32 (1 station, remote I/O stations) Occupied area (Number of inputs
Body size Body size 20 L/min 100 L/min Symbol Filtration area 750 mm2 Specifications Different diameters (IN side < OUT side) Different diameters (IN side > OUT side) Blue element Filtration: 10 m FKM/Oil free (Seal) Nylon Symbol X01 X02 X03 X04 X05 X06 5 7 1260 mm2 Applicable tubing O.D.
Bore size (mm) Standard stroke (mm) Range of manufacturable stroke* Without rod boot With rod boot Without rod boot With rod boot 40 25 to 850 25 to 700 Up to 1200 Up to 950 50 25 to 800 25 to 650 Up to 1150 Up to 900 63 25 to 800 25 to 650 Up to 1150 Up to 900 80 25 to 750 25 to 600 Up to 1100 Up to 900 100 25 to 750 25 to 600 Up to 1100 Up to 850 Refer to pages 692 to 697 for cylinders
T dimension) None Differential pressure indicator Differential pressure indication switch Note) 0 1 5 1 2 3 4 5 1 2 3 4 1 2 3 4 340 410 480 550 620 430 530 630 730 560 650 750 850 04 (1/2B) 06 (3/4B) 08 (1B) 30 FH FH Note) N.C. and N.O. common Note) When the differential pressure indication 1 or 5 is selected, the connection method is 2 to 5. (0 and 1 cannot be selected.)
Symbol Specications X01 Different diameters (IN side < OUT side) X02 Different diameters (IN side > OUT side) X03 Blue element X04 Filtration: 10 m X05 FKM/Oil free (Seal) X06 Nylon 5 20 L/min 750 mm2 7 100 L/min 1260 mm2 Applicable tubing O.D. Metric size Symbol Applicable tubing O.D.
2 600st 400st 500st st: Stroke (mm) MGF 1 100st 200st 300st 0 MGZ 0 50 100 150 200 250 300 350 400 450 500 550 600 Allowable end load F (N) MGT MGGM 100Stroke 8 (Slide bearing type) 7 6 Deflection Y (mm) 1300st 5 1200st 4 1100st 1000st 3 900st D800st 2 600st 700st -X st: Stroke (mm) 400st 500st 1 100st 200st 300st Individual -X 0 0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750
The speed is as indicated below for motorless operation of test operation. 0 0 r/min 1 to 50 Driver capacity [W] Servo motor speed [r/min] 100V class 100 to 400 3000 200V class 100 to 750 1k to 37k 2000 400V class 600 to 55k Analog speed limit maximum speed 0 0 5 35 5. PARAMETERS Used to set the speed at the maximum input voltage (10V) of the analog speed limit (VLA).