Serial interface unit EX500 is capable of controlling up to 64 solenoids, and is compatible with SV1000/2000/3000/4000, VQC1000/2000/4000 valves. The EX500 makes it possible to connect up to 4 valve manifolds with up to 16 solenoids each.

Serial interface unit EX500 is capable of controlling up to 64 solenoids, and is compatible with SV1000/2000/3000/4000, VQC1000/2000/4000 valves. The EX500 makes it possible to connect up to 4 valve manifolds with up to 16 solenoids each.

(Value in the initial state) Vibration resistance: No malfunction occurred in one sweep test between 45 and 2000 Hz. Test was performed to axis and right angle directions of the main valve when pilot signal is ON and OFF.

(Valve in the initial stage) Vibration resistance: No malfunction from test with 45 to 2000 Hz one sweep, to axis and right angle direction of main valve, each one time when pilot signal ON and OFF .

(Values at the initial period) Vibration resistance: No malfunction from test with 45 to 2000 Hz one sweep, to axis and right angle direction of main valve, each one time when pilot signal ON and OFF.

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 0.03 to 0.1 MPa 0.05 MPa 102 /min (ANR) Operating pressure differential range IR Recommended press. differential (3) Press. differential setting min. flow VEX 2000 5000 2000 5000 Bowl capacity between levels (cm 3) Turbine oil Class 1(With no additives

) Single Solenoid Type (SQ1000/2000) 3 Position Type (SQ1000/2000) Positive common specifications 4 Position Dual 3 Port Type (SQ1000/2000) () Positive common specifications SOL.

Operating: 0 to 50C, Stored: 10 to 60C (with no freezing and condensation) Resistance Operating or Stored: 35 to 85%RH (with no condensation) 10 to 500 Hz with a 1.5 mm amplitude or 98 m/s2 acceleration, in each X, Y, Z direction for 2 hrs., whichever is smaller.

Do not drop, bump or apply excessive impacts (300m/s2 or more for reed switches and 1000m/s2 or more for solid state switches) while handling. Although the body of the switch may not be damaged, the inside of the switch could be damaged and cause a malfunction. 2. Do not carry a cylinder by the auto switch lead wires. Never carry a cylinder by its lead wires.

Do not drop, bump, or apply excessive impacts (1000 m/s2) while handling. Although the body of the controller case may not be damaged, the inside of the controller could be damaged and cause a malfunction. 2. The tensile strength of the power supply/output connection cable is 50 N; that of the pressure sensor lead wire with connector is 25 N.

VX2 Table (1) Indication of Flow Rate Characteristics VXK Indication by international standard Corresponding equipment Other indications Conformed standard VXD ISO 6358: 1989 JIS B 8390: 2000 C, b VXZ Pneumatic equipment JIS B 8390: 2000 Equipment: JIS B 8379, 8381-1, 8381-2 VXS VXS S Cv VXB ANSI/(NFPA)T3.21.3 R1-2008 IEC60534-1: 2005 IEC60534-2-3: 1997 JIS B 2005-1: 2012 JIS B 2005-2-3

400 600 800 1000 1200 1400 Cooling capacity [W] Cooling capacity [W] 25C 25C HED HEA 35C 35C 40C IDH 40C 0 10 20 30 40 0 10 20 30 40 Circulating fluid temperature [C] Circulating fluid temperature [C] HRSE018-A-20/23-(T) [50 Hz] [60 Hz] 2000 2000 Ambient temperature Ambient temperature 25C Cooling capacity [W] Cooling capacity [W] 25C 1500 1500 35C 1000 1000 35C 500 500 40C 40C 0 0 0 10

32 40 100, 150, 200, 250, 300, 350 400, 450, 500, 600, 700, 800 900, 1000 2000 1500 50 63 Note) Contact SMC if the maximum stroke will be exceeded.

7000 6000 1500 80 80 5000 4000 1000 63 63 3000 40 50 2000 500 50 1000 40 0 0 5 10 15 20 0 450 400 350 300 250 200 150 100 50 0 Arm length L (mm) Arm length L (in) Allowable load for clamp arm end Refer to the graph on pages 190 and 191 for parts weight of the arm.

32 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000, 1200, 1400, 1600, 1800, 2000 40 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000, 1200, 1400, 1600, 1800, 2000 O P T I O N S T R O K E A D J U S T M E N T U N I T Stroke Adjustment Unit 25 MY-A25L 32 MY-A32L 40 MY-A40L 25 MY-S25L MY-S25B 32 MY-S32L MY-S25B 40 MY-S40L MY-S32B M O R E H O W T O O R D E R S E E N E X T P A G E Courtesy

Lead wire length 2000 mm Cover Concave Pin Nil 6 10 15 20 25 30 50 300 mm 600 mm 1000 mm 1500 mm 2000 mm 2500 mm 3000 mm 5000 mm Lever DC indicator Socket Part no.

Lead wire length 2000 mm -+ Socket Nil 6 10 15 20 25 30 50 300 mm 600 mm 1000 mm 1500 mm 2000 mm 2500 mm 3000 mm 5000 mm Lead wire Connector Hook For DC V114-5LO SY100-30-4A-20 For AC V114A-1LO SY100-30-1A-20 2.

Box 26640, Indianapolis, IN 46226 Tel: (317) 899-4440 FAX: (317) 899-3102 1978-2000 SMC Pneumatics, Inc. All Rights Reserved. August 2000

ZSE50F / ISE50 1 x 10 -5Pam3/s ZSE60F / ISE60 1 x 10 -10Pam3/s IP65 Enclosure Panel mount With bracket Option Panel mount + Front side protection cover To confirm working pressure of hydraulic cylinder Application examples To confirm adsorption of work pieces containing water To confirm primary pressure of cleaning line Features 1 High precision and high resolution 1/2000 (0.1kPa) Positive