(mm ) 0 2 4 M V VX311 -01 1.5 ZCU 0.29 0 2 4 M V VX312 -01 2.2 1 8 0.60 AMJ 0 2 4 M V VX313 -01 3 0.82 Misc. 0 2 4 M V VX311 -02 1.5 0.29 0 2 4 M V VX312 -02 0.60 M V VX3224 -02 2.2 0.64 M V VX3324 -02 0 2 4 M V 0.82 VX313 -02 1 4 Series VX31 Series VX32 Series VX33 M V 3 VX3234 -02 1.1 M V VX3334 -02 M V 4 VX3244 -02 1.6 M V VX3344 -02 M V VX3224 -03 2.2 0.64 M V VX3324 -03 M V VX3234 -03
AN120-M5 AS3001F-06 AN110-01 SY3120-C6 SY3140-01 T0604 x 1 m T0806 x 1 m AS3001F-06 T0604 x 1 m T0806 x 1 m AS3001F-08 AS3001F-06 SY5120-01 SY5140-02 AS3001F-08 AN101-01 AN101-01 T1075 x 1 m T0604 x 1 m T0604 x 1 m T1209 x 1 m T1075 x 1 m AS4001F-10 SY7120-02 SY7140-03 AS3001F-06 AS4001F-10 AS3001F-06 AN110-01 AN200-02 T0604 x 1 m T1075 x 1 m T1209 x 1 m T0604 x 1 m T1075 x 1 m T1209 x 1
Enable Generates an error. 1 Unit Disable Does not generate an error. -10..10 V Selects the analogue input range. (AXB cannot select the following ranges. -10..10 V/ -5..5 V/ -20..20 mA) -5..5 V -10..10 V -20..20 mA (AXA) Sets the analogue input device range. 0..10 V 2 Analogue input range Channel 0..5 V 1..5 V (AXB) 1..5 V 0..20 mA 4..20 mA Offset binary Offset binary.
SX5000-38-16 A SX7000-39-16 A SX7000-38-16 A Dimensions Applicable fittings size d 4 Model A L D KQ2P-04 16 32 6 6 KQ2P-06 18 35 8 8 KQ2P-08 20.5 39 10 10 5/32" 1/4" 5/16" 3/8" Thread type Nil Rc G F KQ2P-10 KQ2P-03 KQ2P-07 KQ2P-09 KQ2P-11 12 6 8.5 10 11.5 43 32 35 39 43 22 16 18 20.5 22 N NPT NPTF T Bolt and gasket part no.
Blanking plug KQ2P-23 KQ2P-04 KQ2P-06 KQ2P-08 KQ2P-10 L Dimensions (mm) A Applicable fitting size d Model A L D KQ2P-23 KQ2P-04 KQ2P-06 KQ2P-08 KQ2P-10 3.2 6 8 10 12 31.5 32 35 39 43 3.2 4 6 8 10 16 16 18 20.5 22 D L DIN rail AXT100-DR-l 7.5 As for l, enter the number from the DIN rail dimensions table.
) 01 32 02 36 30 31 35 30 03 33 30 0D 2 Set at +1.50 deg.C 06 32 0D 37 Temperature setting (with writing EEPROM) F 01 3F 02 37 32 35 30 30 03 33 3F 0D 06 3F 0D Set at 25.0 deg.C 38 Offset setting (with writing EEPROM) F 01 3F 02 38 30 31 35 30 03 33 3F 0D 06 3F 0D Set at +1.50 deg.C HEC 6-1
Recommended flow rate Note) (l/min (ANR)) IN side, OUT side 2 3.2 4 4 6 6 8 1/8" 5/32" 5/32" 1/4" 1/4" 5/16" Internal capacity (cm3) 1.7 Mass (g) ZA Model ZFC050-02 ZFC050-23 ZFC050-04 ZFC100-04 ZFC100-06 ZFC200-06 ZFC200-08 ZFC051-01 ZFC051-03 ZFC101-03 ZFC101-07 ZFC201-07 ZFC201-09 2 7 10 10 20 30 50 7 10 10 20 30 50 4.9 ZX IN/OUT straight piping 4.3 1.7 ZR Metric size Easy installation
KFG2H0425-01 KFG2H0425-02 KFG2H0403-01 KFG2H0403-02 KFG2H0604-01 KFG2H0604-02 KFG2H0806-01 KFG2H0806-02 KFG2H0806-03 KFG2H1075-02 KFG2H1075-03 KFG2H1075-04 KFG2H1008-02 KFG2H1008-03 KFG2H1008-04 KFG2H1209-02 KFG2H1209-03 KFG2H1209-04 KFG2H1210-02 KFG2H1210-03 KFG2H1210-04 KFG2H1613-03 KFG2H1613-04 8 14 8 14 10 16 18 24 36 34 41 67 33 40 66 33 40 66 30 38 63 51 67 19.4 23.8 19.4 23.8 20.9
Applicable cylinder bore size (mm) Elbow type Universal type Port size Inch size Metric size Flat head screwdriver 3.2 4 6 8 10 12 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 1/2" AS121F-M5 AS131F-M5 6, 10, 16, 20 M5 x 0.8 AS221F-01 AS231F-01 20, 25, 32 R 1/8 AS221F-02 AS231F-02 20, 25, 32, 40 R 1/4 AS321F-02 AS331F-02 40, 50, 63 R 1/4 AS321F-03 AS331F-03 40, 50, 63 R 3/8 AS421F-04 AS431F-04 63, 80,
-01-06-X214 AS2001F-06-X214 AS2301F-01-06-X214 DREC32 AS2201F-01-06-X214 AS3001F-08-X214 AS2301F-01-06-X214 REC40 AS3201F-02-08-X214 AS3001F-08-X214 AS3301F-02-08-X214 -X Use the recommended speed controllers.
-01-06-X214 AS2001F-06-X214 AS2301F-01-06-X214 DREC32 AS2201F-01-06-X214 AS3001F-08-X214 AS2301F-01-06-X214 REC40 AS3201F-02-08-X214 AS3001F-08-X214 AS3301F-02-08-X214 -X Use the recommended speed controllers.
-01-06-X214 AS2001F-06-X214 AS2301F-01-06-X214 DREC32 AS2201F-01-06-X214 AS3001F-08-X214 AS2301F-01-06-X214 REC40 AS3201F-02-08-X214 AS3001F-08-X214 AS3301F-02-08-X214 -X Use the recommended speed controllers.
OUTLINE DRAWINGS 91 to 9-5 9.1 Driver . 92 9.2 Connector. 95 10. CHARACTERISTICS 101 to 10-7 10.
When ordering with manifolds, add "-N" at the end of the manifold number. 1 2 3 4 5 6 7 8 ... n: Stations 53 Silencer cover Blanking plug (for One-touch fitting) L Dimensions 04 06 08 10 Applicable fitting size d 4 6 8 10 A Model A L D KQ2PKQ2P-04 KQ2P-06 KQ2P-08 KQ2P-10 16 18 20.5 22 32 35 39 43 6 8 10 12 This is inserted into the cylinder port and SUP and EXH ports that are not used.
Model XT13-394-06 XT13-394-10 INA-48-1-06 INA-48-1-10 INA-48-16-10 INA-48-16-06 INA-48-58-10-H INA-48-58-06-H Port size Rc3/4 Rc1 Rc3/4 Rc1 Rc3/4 Rc1 Rc3/4 Rc1 Relief mechanism Non-relief Relief Non-relief Fluid Deionized water (Pure water) Air, N2 Proof pressure 1.9 MPa 1.5 MPa Max. operating pressure 1.3 MPa 1.0 MPa Set pressure 0.1 to 1.0 MPa 0.05 to 0.5 MPa 5 to 60C Ambient and fluid
X Port size) Speed controller System figure System Solenoid valve SYJ7l40-01 Rc(PT)1/8 (S = 12.6mm2) AN110-01 (S = 35mm2) 4 X 1/8 AS2301F-01-04 A 02 03 AS3301F-06 6 X 1/4 B q 02 03 AS3301F-08 SYJ7l40-02 Rc(PT)1/4 (S = 12.6mm2) 8 X 1/4 C AN200-02 (S = 35mm2) 02 03 AS3301F-10 10 X 1/4 D 12 X 1/4 12 X 1/2 AS4001F-12 w E 1.2-53 Series SYJ7000 How to Order Light and surge voltage suppressor
L 285.5 21 273 310.5 23 298 22 335.5 25 323 24 360.5 27 348 26 385.5 29 373 28 410.5 31 398 30 435.5 33 423 32 460.5 35 448 34 485.5 37 473 36 39 498 38 40 510.5 Fitting blank plug KQP-23-X19 KQP-04-X19 KQP-06-X19 KQP-08-X19 KQP-10-X19 L A Dimensions (mm) Applicable fitting d Part number A L D D KQP-23-X19 KQP-04-X19 KQP-06-X19 KQP-08-X19 KQP-10-X19 3.2 4 6 8 10 16 16 18 20.5 22 31.5 32
capacity [kW] 8 8 6 6 4 4 2 2 0 0 5 10 15 20 25 30 35 5 10 15 20 25 30 35 Circulating fluid temperature [oC] Circulating fluid temperature [oC] 50Hz 60Hz Fig. 8-5 Cooling capacity(HRS100-A-20/40/46-) 8.4.2 HRS150-A-20/40/46: Ambient temperature: 32 oC : Ambient temperature: 40oC : Ambient temperature: 45 oC 18 18 16 16 14 14 Cooling capacity [kW] Cooling capacity [kW] 12 12 10 10 8 8 6 6
P=17.5 1 2 3 4 5 6 7 8 n: Stations 53 Silencer cover Blanking plug (For One-touch fitting) L Dimensions 04 06 08 10 Applicable fittings size d 4 6 8 10 A A L D Model KQ2PKQ2P-04 KQ2P-06 KQ2P-08 KQ2P-10 16 18 20.5 22 32 35 39 43 6 8 10 12 It is inserted into an unused cylinder port and SUP/EXH ports.
Maintenance detection signal ON OFF Output Requirement for maintenance detected ON OFF Input External switch signal 1, 2 455 IZN10 Series Dimensions 06 07 06 07 Energy saving static neutralization nozzle/IZN10-01 High flow rate nozzle/IZN10-02 20 Note 1) (110) 16 100 5 5 46 A 3.4 18.5 11 6 5 6 A 8 7 (Tap for ground wiring) M3 x 0.5 depth 4 40 25 12 A 93.6 A-A (mm) A Model 01 02 01 02 IZN1006