terminal 24, 12, 6, 5, 3 VDC R port P, E port M8 connector G: Lead wire length 300 mm L: With lead wire (Length 300 mm) M: With lead wire (Length 300 mm) MN: Without lead wire D: With connector W0: Without connector cable M: Common exhaust for the pilot and main valve + + + + + R port P, E port H: Lead wire length 600 mm LN: Without lead wire LO: Without connector MO: Without connector DO
M5 standard 1/8 standard 1/4 standard 3/8 standard 1/2 standard 100 200 205 300 400 Applicable tubing O.D.
T4 = 0.05 [s] T1 = V/a1 = 300/5000 = 0.06 [s], T3 = V/a2 = 300/5000 = 0.06 [s] T2 = = = 0.94 [s] L 0.5 V (T1 + T3) V 300 0.5 300 (0.06 + 0.06) 300 T4 = 0.05 [s] Therefore, the cycle time can be obtained as follows.
Inch size ARJ310F-N01 5/32" 1/4" 03 07 14-4-11 9 Series ARJ310 Flow Characteristics Inlet pressure: 0.7 MPa ARJ310-01 ARJ310F-01-04 ARJ310F-01-06 0.7 0.7 0.7 0.6 0.6 0.6 Outlet pressure (MPa) Outlet pressure (MPa) Outlet pressure (MPa) 0.5 0.5 0.5 0.4 0.4 0.4 0.3 0.3 0.3 0.2 0.2 0.2 0.1 0.1 0.1 0.0 0.0 0.0 0 100 200 300 400 500 600 0 100 200 300 400 500 600 0 100 200 300 400 500 600 Flow
) 23(30) 32(42) 23(30) 1 1 2-3/8, 1/2, 3/4 2-3/8, 1/2, 3/4 3/8, 1/2, 3/4 R1, R2 port X(PE) port 1/8 3/8, 1/2, 3/4 R1, R2 port X(PE) port 1/8 30(42) 30(42) 30(42) 30(42) P port P port ( ): 3/4 Dimensions inside are for rubber seals. ( ): 3/4 3-10-24 25 ISO Standard Solenoid Valve: Size 2 Metal Seal/Rubber Seal Series VQ7-8 Prewired Connector Type 2 position single : VQ7-8-FG-S-SC single (Reverse
) 5 3 1 23(30) 38(53) 32(42) 1 23(30) 2-3/8, 1/2, 3/4 30(42) 30(42) X(PE) port 1/8 2-3/8, 1/2, 3/4 3/8, 1/2, 3/4 R1, R2 port X(PE) port 1/8 30(42) 30(42) 3/8, 1/2, 3/4 R1, R2 port P port P port ( ): 3/4 Dimensions inside are for rubber seals. ( ): 3/4 3-10-25 Series VQ7-8 Construction DIN Terminal Type Metal seal Rubber seal type VQ7-8-FG-SVQ7-8-FG-S-R !
When either 0002H or 0003H is selected for the Speed Unit (parameter 41), set the Speed Base Unit (parameter 42) to a number between -3 and 0. 5. When 0004H is selected for the Speed Unit (parameter 41), set the Speed Base Unit (parameter 42) to 0. 8-130 8 MECHATROLINK-III Commands Parameter Name Setting Units Factory Enabled Size Category No.
63 300 80 300 100 300 *1 The maximum rod length of the MWB32-XC68 is 1800 mm.
Terminal block Ventilation direction Ventilation direction F 42 L 14 H 4 x 13 M N P [100 VAC specification] Power cable (Length: approx. 1.9 m) [200 VAC specification] Power cable outlet (17) Drain tube (O.D. 10, length approx. 0.8 m) Dimensions [mm] Model Port size A B C D E F G H L M N P Q IDU8E Rc3/4 270 485 859 31 90 365 130 230 300 80 300 328 15 IDU11E 909 IDU15E1 Rc1 300 620 960 79
Symbol Length Nil 3 6 10 150 mm 300 mm
22.5 42 24.5 42 20.5 37 22(20.5) 37 23.5 37 16 The values inside ( ) are for D-Z73.
(mm) H1 6 7 8 11 11 H 36 40 45 53 56 GY 5 5.5 7 8 10 GX 10 8.5 9 11.5 11.5 EY 26 42 54 64 72 D 12 14 16 20 20 C 54 68 86 104 124 B1 17 19 22 27 27 BY 7 8 9 9 12 B 24 28 32 39 50 BX 9 6.5 8 10 11 ET AL 19.5 23.5 27 32 32 BS 37 45 44 54 53 K 5.5 5.5 6 7 7 A 22 26 30 35 35 BT Model MUB25 MUB32 MUB40 MUB50 MUB63 Stroke range (mm) 5 to 300 5 to 300 5 to 300 5 to 300 5 to 300 M5 x 0.8 depth 7.5
(mm) H1 6 7 8 11 11 H 36 40 45 53 56 GY 5 5.5 7 8 10 GX 10 8.5 9 11.5 11.5 EY 26 42 54 64 72 D 12 14 16 20 20 C 54 68 86 104 124 B1 17 19 22 27 27 BY 7 8 9 9 12 B 24 28 32 39 50 BX 9 6.5 8 10 11 ET AL 19.5 23.5 27 32 32 BS 37 45 44 54 53 K 5.5 5.5 6 7 7 A 22 26 30 35 35 BT Model MUB25 MUB32 MUB40 MUB50 MUB63 Stroke range (mm) 5 to 300 5 to 300 5 to 300 5 to 300 5 to 300 M5 x 0.8 depth 7.5
Disconnect and remove all cabling which enters the limit switch housing (300). Remove screws (325), 3 pcs. and lift out the limit switch base plate (324) complete with switches, LUI and connector block. Open screw (326) and turn the limit switch housing (300) from the positioner housing. Remove the electronics cover (39). Proceed with the valve controller as applicable.
T4 = 0.05 [s] T1 = V/a1 = 300/5000 = 0.06 [s], T3 = V/a2 = 300/5000 = 0.06 [s] T2 = = = 0.94 [s] L 0.5 V (T1 + T3) V 300 0.5 300 (0.06 + 0.06) 300 T4 = 0.05 [s] Therefore, the cycle time can be obtained as follows.
connector length other than 300 mm, order the connector assembly on page 32 separately. t Vacuum (V) port y Option5 (For details on the Function/Application, refer to page 42.)
(mm) D2 L A M D1 Applicable tubing KXH04-M5 KXH04-M6 KXH04-01S KXH06-M5 KXH06-M6 KXH06-01S KXH06-02S KXH08-01S KXH08-02S KXH08-03S KXH10-02S KXH10-03S KXH10-04S KXH12-03S KXH12-04S M5 x 0.8 M6 x 1 38.5 11 13 39 35 8 10.4 16 2.5 4.0 4.0 4 40 39.5 40 42 45 46 49 50 58 59 62 60 63 16 36 1 8 M5 x 0.8 M6 x 1 12 2.5 3 4.0 4.0 5.6 5.6 15 8 36 6 15 12.8 17 1 8 1 4 1 8 38 39 42 43 44 20 26 28 34 42
3 contained in one kit, and can be ordered using the kit number for each cylinder bore size. 2.4-7 Series MUW Basic: MUWB Rod end male thread (mm) H1 6 7 8 11 11 H 36 40 45 53 56 GY 5 5.5 7 8 10 GX 10 8.5 9 11.5 11.5 EY 26 42 54 64 72 Model MUWB25 MUWB32 MUWB40 MUWB50 MUWB63 Stroke range (mm) 5 to 300 5 to 300 5 to 300 5 to 300 5 to 300 D 12 14 16 20 20 C 54 68 86 104 124 B1 17 19 22 27 27
50 100 150 200 250 300 350 400 30 50 100 150 200 250 300 350 400 450 500 Product weight [kg] 1.74 1.81 1.98 2.24 2.42 2.59 2.77 2.94 3.12 2.74 2.85 3.14 3.42 3.82 4.11 4.39 4.68 4.97 5.25 5.54 In-line Motor Series EQY16D Stroke [mm] 30 50 100 150 200 250 300 Product weight [kg] 0.72 0.76 0.87 1.01 1.12 1.23 1.34 Series EQY25D EQY32D Stroke [mm] 30 50 100 150 200 250 300 350 400 30 50 100
Stroke (mm) Up to 10 Up to 30 Up to 50 Up to 75 Up to 100 Max. speed (mm/s) Up to 100 Up to 300 Up to 400 Over 400 Up to 100 Up to 300 Up to 400 Over 400 Up to 100 Up to 300 Up to 400 Over 400 Up to 100 Up to 300 Up to 400 Over 400 Up to 100 Up to 300 Up to 400 Over 400 6 (7) (8) (9) 10 15 Selection graph 20 (10) (11) (12) (13) (14) (15) (17) (16) 25 32 The maximum speeds for 10 to 32 are