FAN TYPE IONIZER SPL, IONIZER, FAN TYPE
FAN TYPE IONIZER, IONIZER, FAN TYPE, 869, 260 lb
FAN TYPE IONIZER, IONIZER, FAN TYPE, 869, 340 lb
Mounting bracket for series IZF10 Fan Ionizers Mounting bracket for series IZF10 Fan Ionizers ; Includes mounting hardware
Mounting bracket for series IZF10 Fan Ionizers Mounting bracket for series IZF10 Fan Ionizers ; Includes mounting hardware
AC Adapter for series IZF10 and IZS40 ionizers. Option with or without AC cord. Note: NOTcompatible with IZS41/42. AC Adapter for series IZF10 and IZS40 ; Optional AC cord ; Note: NOT compatible with IZS41/42
AC Adapter for series IZF10 and IZS40 ionizers. Option with or without AC cord. Note: NOTcompatible with IZS41/42. AC Adapter for series IZF10 and IZS40 ; Optional AC cord ; Note: NOT compatible with IZS41/42
type=GUIDE&id=IZF10-E" target="_blank">here.
The IZF10 is SMC's compact fan ionizer. The fan ionizer emits static eliminating ions using ambient air, suitable for when an air supply is inconvenient or unavailable. Treatment area can be up to 1200mm / 47 in away. The fan is operated by a power switch, with an ion balance adjustment trimmer in the back. Available with a low noise or rapid static elimination fan.
The IZF10 is SMC's compact fan ionizer. The fan ionizer emits static eliminating ions using ambient air, suitable for when an air supply is inconvenient or unavailable. Treatment area can be up to 1200mm / 47 in away. The fan is operated by a power switch, with an ion balance adjustment trimmer in the back. Available with a low noise or rapid static elimination fan.
For the IZF10/10R, the excess current on output circuit and incorrect high voltage alarms cannot be checked.
And for the IZF21/31, the excess current on output circuit, incorrect high voltage, power supply failure, fan motor failure, CPU failure, maintenance warning, emitter cartridge mounting failure, and automatic cleaning failure alarms cannot be checked.
For IZF10/10R series ionizers, the power cable connector used is an e-CON connector. e-CON connectors can be ordered individually using the part number “ZS-28-C.”
Connect the numbers on the connector body in the following manner: 1 to +24 VDC (brown), 2 to 0 V (blue), 3 to F.G. (green), and 4 to the error signal (purple).
[Features] · Air flow adjustment function added (IZF10R). · High-speed ionization. · Allows you to detect emitter contamination. · Compact fan type with simple functions. · Alarm function for reporting high voltage issues or maintenance warnings.
The IZF10R shares the same fan size and ±13V ion balance with the IZF10, with two new features. A new 4-speed fan adjuster knob is added, including one higher and one lower speed for faster neutralization and greater range, or quieter operation. In addition to the high current/high voltage switch output, a second output signal indicates when emitter maintenance is required.
The IZF10R shares the same fan size and ±13V ion balance with the IZF10, with two new features. A new 4-speed fan adjuster knob is added, including one higher and one lower speed for faster neutralization and greater range, or quieter operation. In addition to the high current/high voltage switch output, a second output signal indicates when emitter maintenance is required.
30 2 x 3.5 depth 1 4 x M4 x 0.7 depth 6 Variable angle (Female thread mounting) 90 19.5 1.9 (Power supply switch) 6 (With connector plugged in) 37.5 R41 (84) 25 R76 27 Fan Type Ionizer IZF10/IZF10R Series Dimensions IZF21/31 IZF10/IZF10R Technical Data Power supply cable IZF10-CP L 45 2 36 2 Terminal semi-stripped 3 1 7 1 4.3 4 1 Wiring/IZF10 Pin no.
This trimmer is used to adjust the offset voltage (ion balance). IZF21/31 series ionizers are marked with “ADJUST” on the front of the product.
For details on adjusting the offset voltage, refer to the operation manual.
The IZF series operation manual can be found here.
When abnormal discharge occurs for longer than 100 ms, the incorrect high voltage alarm will be activated. Discharge may be caused by foreign matter or water droplets adhering to the emitter (electrode needle). In order to clear the alarm, remedy the cause of the error after stopping the power supply, and then turn the power ON again.
-CG1 (With AC cord) IZF10-CG2 (Without AC cord) Model L(mm) IZS40-CP 3000 IZS40-CPZ 9850 Model L(mm) IZS41-CP 3000 IZS41-CPZ 9850 Model L(mm) IZS41-CF02 2000 IZS41-CF05 5000 IZS41-CF08 8000 IZS41-CG1 (With AC cord) IZS41-CG2 (Without AC cord) Remote controller/ IZS41-RC 8.
X14 1 1 1 1 2 2 3 3 4 5 7 7 IZD IZE IZH Drop prevention cover When attached to the body Transition wiring cable Remote controller/IZS41-RC IZS41 CF Transition wiring cable 02 05 08 Full length 2 m Full length 5 m Full length 8 m AC adapter For IZS40 IZF10 C AC adapter G1 G2 AC adapter + AC cord AC adapter (without AC cord) AC cord is only for use in Japan.