Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: M (SI Unit Only), Lead Wire: None, Bracket: A (Bracket A, Interchangeable with ISE70), Operation Manual/Calibration Certificate: Y (None)
Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: None, Operation Manual/Calibration Certificate: Y (None)
Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: M (SI Unit Only), Lead Wire: None, Bracket: None, Operation Manual/Calibration Certificate: Y (None)
Pressure Range: ISE71 (0 to 1.6 MPa), Piping: N02 (NPT 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: None, Operation Manual/Calibration Certificate: Y (None)
Manual/Calibration Certificate: Y (None)
Pressure Range: ISE77G (0 to 10 MPa), Piping: N02 (NPT 1/4), Orifice: None, Unit Specification: M (SI Unit Only), Lead Wire: None, Bracket: None, Operation Manual/Calibration Certificate: Y (None)
Pressure Range: ISE76G (0 to 5 MPa), Piping: N02 (NPT 1/4), Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m), Bracket: B (Bracket B), Operation Manual/Calibration Certificate: Y (None)
Pressure Range: ISE76G (0 to 5 MPa), Piping: N02 (NPT 1/4), Orifice: T (Orifice shipped with the Product), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m), Bracket: None, Operation Manual/Calibration Certificate: Y (None)
Pressure Range: ISE70G (0 to 1 MPa), Piping: N02 (NPT 1/4), Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: None, Operation Manual/Calibration Certificate: Y (None)
Pressure Range: ISE70G (0 to 1 MPa), Piping: N02 (NPT 1/4), Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m), Bracket: B (Bracket B), Operation Manual/Calibration Certificate: Y (None)
Pressure Range: ISE77G (0 to 10 MPa), Piping: N02 (NPT 1/4), Orifice: None, Unit Specification: M (SI Unit Only), Lead Wire: None, Bracket: A (Bracket A, Interchangeable with ISE75[H]), Operation Manual/Calibration Certificate: Y (None)
From the point just found, draw a line to the Y-axis to find the air consumption. The result is approximately 50 l/min (ANR). SUP = 0.2 MPa 150 100 50 1 0 2 3 4 5 6 7 Caution Cycle (Hz) 1. These flow characteristics are for fresh water (viscosity 1mPas, specific gravity 1.0). 2.
Port Sizes 14~1 Float Type Automatic Drain Valve T E C H N I C A L SPECIFICATIONS Type (N)AD402 (N)AD600 Operating Pressure 1.5~9.9 Bar 3~9.9 Bar 22~145PSI 45~145PSI Max Supply Pressure 15 Bar / 220PSI Max Operating Pressure 9.9 Bar / 145PSI Ambient & Fluid Temperature 5 ~ 60C / 40~140F Port Size 1/2 3/4, 1 Drain Port 3/4 3/4, 1 D I M E N S I O N S AD S E R I E S A U I T O D R A I N S S Y
For positive pressure 80 ISE 02 N M For vacuum/ compound pressure M 80 ZSE 02 N Option 3 Rated pressure range Operating Note) manual (Booklet) (CD-ROM) Operating Note) manual 80 80F Calibration certificate Calibration certificate 0 to 101 kPa 100 to 100 kPa Symbol Symbol (Booklet) (CD-ROM) K T R Nil Piping Y W R1/4 (M5 female threaded) Rear ported 02 Note) All texts in both English
RoHS 3-Screen Display High-Precision Digital Pressure Switch: For Air ISE70/71 Series How to Order ISE70 02 M L2 Pressure range Option 3 Symbol Description ISE70 0 to 1 MPa ISE71 0 to 1.6 MPa Symbol Description Nil Operation manual Y None K Operation manual + Calibration certicate Piping specification Symbol Description 02 Rc1/4 N02 NPT1/4 F02 G1/41 T Calibration certicate Option 2 Symbol
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: S (NPN Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: None, Operation Manual: Y (w/o Operation
Rated Vacuum Range: -101 to 0 kPa, Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)