(mm) Auto Switch Mounting Height D-A9l(V) D-M9l(V) D-M9lW(V) D-M9lA(V) D-H7l D-H7lW D-H7BA D-H7NF D-C7l D-C80 Auto switch model D-B5l D-B64 D-B59W D-G5NT D-H7C D-G39A D-K39A D-A3lA D-A44A D-C73C D-C80C Hs Hs Hs Hs Hs 20 24.5 25.5 25 60 69.5 25 27 28 27.5 62.5 72 32 30.5 31.5 31 66 75.5 40 34.5 35.5 35 70 79.5 Bore size D-X Technical Data 263 CM2 Series Auto Switch Proper Mounting Position
P, R port M5 x 0.8 VQZ VZ X port (External pilot) M5 x 0.8 A port M5 x 0.8 VS VFN 4-4-19 20 Series SYJ500 How to Order Light/Surge voltage suppressor Rated voltage DC Electrical entry for G, H, L, W Electrical entry for D 5 6 V S R 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC Nil Without light/surge voltage suppressor Nil Without light/surge voltage suppressor S Z R U With light/surge voltage suppressor
D 16 F9BW Number of auto switches Number of fingers 2 2 fingers Nil S 2 pcs. 1 pc.
ported with M5 port (Single acting) Applicable Auto Switch/ Switch types D-Y5/6 and D-Y7 cannot be mounted when equipped with dust cover/MHZJ2.
of auto/proximity switches None Yes (cable length 0.3m) Nil S Home position switch D-F9N D-F9P D-F9G D-F9H D-F9GL D-F9HL D-F9B D-F9NL D-F9PL D-F9BL N.O.
/O (RIO) System NKE Corp.: Uni-wire H System SUNX Corp.: S-LINK System (16 output points) SUNX Corp.: S-LINK System (8 output points) Fuji Electric Co.: T-LINK Mini System DeviceNet, CompoBus/D (OMRON Corp.)
+ AL AC2000 to AC6000 Pressure switch AF + S + AR S AC2020 to AC6020 AC2030 to AC4030 Thread AF + AFM + S + AR AC100: M5 X 0.8 AC200: 1/8 AC250: 1/4 AC300: 1/4 AC400: 3/8 AC500: 3/8 AC550: 1/2 AC600: 1/2 Metric thread (M5) Rc (PT) NPT G(PF) AC1000 to AC6000 AF + T + AR + AL N F T T type interface AC1020 to AC6020 AF + T + AR AC2030 to AC4030 AF + AFM + T + AR Port size M5 01 02 03 04 06
Max. tightening torque (Nm) 21H9 3 MHZ2-40 M8 x 1.25 11.8 MHL M2.5 x 0.45 0.49 26H9 3.5 M2.5 x 0.45 0.49 34H9 4 MHR M3 x 0.5 0.88 42H9 4 M4 x 0.7 2.1 MHK Perpendicular mounting (Body tapping) M5 x 0.8 4.3 M5 x 0.8 4.3 MHS M6 x 1 7.3 Note) Use body tapped for D-Y59, D-Y69, D-Y7P with auto switch types.
Angle adjusting screw Angle adjusting screw Angle adjusting screw n o A R ti n 0 0 n c ot g 9 e 9 o l e y at ir ti y c d a a a io e d w g w ir n j n u y d y ti s ra e e g s ti k k u n n n g j ti of d g of s d a e u ir e e e e j d of c l g a g ti g o n n e n k A n l g n ra ra A e y n n w io io a y at at 9 ot ot 0 R R The rotation range under the adjustment of an angle at 60 is indicated
/C8 D-C73C/C80C D-B5/B6 D-B59W D-A3/A4 D-A3A/A44A D-A3C/A44C D-A7/A8 D-A7H/A80H D-A73C/A80C D-A79W D-A5/A6 D-A59W D-A9 D-A9V D-Z7/Z8 D-H7 D-H7C D-H7BAL D-H7F D-H7W D-G5/K5 D-G5BAL D-G59F D-G5NTL D-G5W/K59W D-G39/K39 D-G39A/K39A D-F7/J7 D-J79C D-F7F D-F7BAL D-F7BAVL D-F7V D-F7NTL D-F7W (V) D-F5/J5 D-F5BAL D-F5W/J59W D-F5F D-F5NTL D-G39C/K39C D-M9 D-M9V D-F9W D-F9WV D-F9BAL D-Y59A/Y7P/Y59B
Panel mounl adapter H i s h-p reci s io n D i s *"l?
S U D side D U side 2 to 10 stations B Special specifications M 2 to 20 stations Both sides Made to order. When using both types, specify C4 and C6 specifically; do not just use X marking.
Panel mounl adapter H i s h-p reci s io n D i s *"l?
d Connection thread M Model H (Width across flats) L A M Min. port size Applicable fitting size d Weight [g] d 4 M5 x 0.8 KQ2N04-M5m 7 29.7 26.7 13.4 2.5 2.4 6 M5 x 0.8 KQ2N06-M5m 7 29.7 26.7 13.4 2.5 2.6 m: A (Brass), N (Brass + Electroless nickel plating) M A L H Connection thread Adapter: KQ2N (Sealant) Applicable fitting size d Connection thread R Model H (Width across flats) L A*1 M
ribs F: M5 x 0.8 F: M6 x 1 F: M8 x 1.25 F: Rc Y 1 8 Model A 1.2 2.6 4.8 7 9 ZPT20 U C ZPT25 U C ZPT32 U C 1.6 0.8 20 23 1.7 14 23 6 8 6.2 23 29 29 4 28 5 8 8 12 12 25 1.8 M4 x 0.7 1 14.5 23.5 23.5 29.5 29.5 4.5 32 35 2.3 Deep 2.5 M5 x 0.8 1 8 B C D E G D E G D E G D E G F: M5 x 0.8 F: M6 x 1 F: M8 x 1.25 F: Rc Y Model A ZPT25D 25 28 20 5 29 8 6 29 8 8 35 12 6.2 35 12 10 b c d e Y Elliptic
PA PB PP PS S TW W XB Z Model CX REBHT25 REBHT32 9 65 108 18 51 209 110 136 9.5 250 18 22.5 12 66 115 14 61 219 124 150 2 265 MQ RHC RZQ D-X Individual -X 1019 Series REBH Proper Auto Switch Mounting Position (Detection at stroke end) Piping port surface A B Proper Auto Switch Mounting Position A dimension B dimension Auto switch model D-Y5 D-Y6 D-Y7P D-Y7PV D-Y5 D-Y6 D-Y7P D-Y7PV D-Y7W
There may be large variations depending on the surrounding environment (variations on the order of 30%). 66 Solid State Switches/Direct Mount/ D-Y59 /D-Y69 /D-Y7P(V) Series MGP Auto Switch Specifications D-Y5, D-Y6, D-Y7P, D-Y7PV (with indicator light) D-Y7PV D-Y59B D-Y59A D-Y69A D-Y7P D-Y69B Auto switch part no.
UM e Connection thread (Male thread) Width across flats D M5 x 0.8 A5 M5 x 0.8 B 3 A Model A B C2 D Vacuum inlet direction q Pad dia.
flange surface Symbol S K L S L M K L M Pilot port direction Solid state auto switch D-M9P(M)(L)(Z) Left flange surface D-M9B(M)(L)(Z) D-A90(L) D-A93(M)(L)(Z) 1 Reed auto switch Right flange surface Without auto switch (with built-in magnet) 2 When the seal material is not being changed, there is no need to select a symbol.