SMC Corporation of America
Elite Part Number Search
Search Results "IBG10N-11"

MNPN MPNP CN4 24 VDC for I/O signal 24 VDC for I/O signal CN4 1 Step Motor (Servo/24 VDC) Specific Product 1 COM+ COM+ 2 2 COM COM 3 3 IN0 IN0 4 4 IN1 IN1 5 5 IN2 IN2 6 6 IN3 IN3 7 7 RESET RESET 8 8 STOP STOP Load Load 9 9 OUT0 OUT0 10 10 OUT1 OUT1 11 11 OUT2 OUT2 12 12 OUT3 OUT3 13 13 BUSY BUSY 14 14 ALARM ALARM Input Signal Output Signal Name Contents Name Contents COM+ Turns on when the

v*11 v*11 v*11 v*11 *1 Drain guide is NPT1/8 (applicable to the AF20-A) and NPT1/4 (applicable to the AF30-A to AF60-A).

Maximum stations are 18. 18 6 19 7 20 8 21 9 22 10 23 11 24 1.

KQ2U23-M5 38 34.5 2.2 2.2 9 M5 X 0.8 10 9.6 41 44 9.6 15.5 37 38 14 3.4 2.9 3.2 1 8 KQ2U23-01S KQ2U23-02S 11 14 1 4 39.5 KQ2U04-M5 M5 X 0.8 M6 X 1.0 4 2.2 2.2 Kl KQ2U04-M6 40 36 10 11 10.4 16 4 10.4 1 8 42 38 KQ2U04-01S 4.2 4.2 11 Ml 1 4 KQ2U04-02S 46 40 20 14 42.5 KQ2U06-M5 M5 X 0.8 M6 X 1.0 2.2 2.2 12 KQ2U06-M6 43 39 13 Hl 1 8 12.8 45.5 41.5 KQ2U06-01S 12.8 11 17 6 1 4 49 43 17

(M): 10-SYJ5223-M-M5 DIN Terminal (D): 10-SYJ5223-D-M5 M8 connector (WO): 10-SYJ5223-WO-M5 Approx. 300 (Lead wire length) Applicable cable O.D. 3.5 to 7 MAX.10 28.1[35.1] 60.9 53.4 12.7 M8 x 1 32.6 42.1 15.1 39.2[46.2] Approx. 300 (Lead wire length) Pg7 20 20 20 20 107[111.4] 3 3 3 3 87.4[91.8] 105.2 125.2 90.4 77.4 45.4 127 11 11 11 11 23 2-2.6 (For mounting) 2-2.6 (For mounting) 2-2.6

'I. 78 2S 52 14 / 113 21 30 72 23 17 M1 2X l .75 _boot With boot PW S W H 12 ... 1 h f zz j IBore olze k U M MM MM (mm) XIUS N P PG PH PL 40 6 71 11 M1 4Xl .5 7/' 6 20 27 'I, 42 11 20 45 153 8 51 215 43 11 .2 59 223 168 0 I50 58 237 52 11.2 66 245 50 7 80 11 M18Xl .5 30 0/, 46 10 21 V.

Standard Body Lead wire type In-line electrical entry type Perpendicular electrial entry type Explanatory drawing Auto switch model L L L Finger position D-Y59 D-Y7P D-Y7W D-Y69 D-Y7PV D-Y7WV D-M9V D-M9WV D-M9AVL D-M9 D-M9W D-M9AL Air gripper model 11 13 3.5 6.5 4 11 13 5 7 5 3 8 6 5 3.5 5 3.5 No setting 9 11 1.5 4.5 2 9 11 3 5 3 1 6 4 3 1.5 3 1.5 13 15 5.5 8.5 3 6 4 13 15

Model Auto switch mounting Cushion Rubber Bore size (mm) Port size Lubrication Action Standard stroke Note 2) (mm) Long stroke (mm) Note 1) Note 2) Model Air 10-/21-CG120 10-/21-CG125 10-/21-CG132 10-/21-CG140 10-/21-CG150 10-/21-CG163 10-/21-CG180 10-/21-CG1100 11-/22-CG120 11-/22-CG125 11-/22-CG132 11-/22-CG140 11-/22-CG150 11-/22-CG163 11-/22-CG180 11-/22-CG1100 25, 50, 75, 100, 125, 150

Series 10-/11-/21-/22-CDG1 Series 10-/11-REC Series 10-/11-CDM2X Series Perpendicular entry is unavailable.

0 -0.043 0 -0.043 2H9 6 7 9 11 12 MRHQ 3H9 8h9 4H9 10h9 6H9 12h9 MA 8H9 14h9 DTA M4 x 0.7 M4 x 0.7 M5 x 0.8 M5 x 0.8 M6 x 1 SC 9 9 12 14 19 SB 8 9.5 9.5 11 11 R 44 53 62 76 95 SA 4.5 5.5 5.5 6.6 6.6 Y 6 8 7 7.5 8 O 4.5 4.5 5 5.5 6 P M5 x 0.8 M5 x 0.8 M5 x 0.8 M5 x 0.8 Q 11 12 14 17 20 TB 8 8 10 10 12 UA M4 x 0.7 M5 x 0.8 M5 x 0.8 M6 x 1 M6 x 1 UB 6 7.5 10 9 12 VA VB 3 4 4 5 6 WA WB 2 2 2

(inch) Min. port size D Note) L Q M2 M1 Weight (g) Model Applicable tubing KQ2T01-03 KQ2T01-07 KQ2T03-05 KQ2T03-07 KQ2T05-07 KQ2T07-09 KQ2T07-11 KQ2T09-11 KQ2T09-13 KQ2T11-13 10.4 13.2 11.4 13.2 13.2 15.2 17.9 17.9 21.7 21.7 18 20.5 19.5 20.5 20.5 23 26 26 29 29 4.5 5.3 4.8 5.3 5.3 6 6.6 6.6 7.8 7.8 16 17 16.5 17 17 18.5 21 21 22 22 5 8 6 8 8 11 17 17 26 28 5 32 2.5 15.5 1 8 1 4 3 16 3

8 @2 @1 SOL.B Station 11 SOL.A @5 Light/Surge voltage suppressor @1 @6 !

Dimensions: Pad Unit ZP2-B04MB ZP2-B06MB ZP2-B08MB 4.5 8 8 6 6 3 4 4 2 1.4 1.5 1 2 2 2 2 9 9 9.6 6 4 4 4.6 2.5 2.5 2.5 1.5 3.3 4.7 4.1 6 7 8 4.8 9 8.4 ZP2-B10MB ZP2-B15MB ZP2-B20MB 15 11 10.8 11 7.8 4.6 7.8 4.6 4.6 5.5 3.5 4.5 3.5 3 3.5 13 11 9.5 18 14.4 10.8 9.4 12 6.8 15 20 10 21 16 11 Adapter Mounting Dimensions If an adapter will be made by the customer, design the adapter with the dimensions

Dimensions: Pad Unit ZP2-B04MB ZP2-B06MB ZP2-B08MB 4.5 8 8 6 6 3 4 4 2 1.4 1.5 1 2 2 2 2 9 9 9.6 6 4 4 4.6 2.5 2.5 2.5 1.5 3.3 4.7 4.1 6 7 8 4.8 9 8.4 ZP2-B10MB ZP2-B15MB ZP2-B20MB 15 11 10.8 11 7.8 4.6 7.8 4.6 4.6 5.5 3.5 4.5 3.5 3 3.5 13 11 9.5 18 14.4 10.8 9.4 12 6.8 15 20 10 21 16 11 Adapter Mounting Dimensions If an adapter will be made by the customer, design the adapter with the dimensions

[90.4] 300 (Lead wire length) 107 79.8 VS 45.4 45.4 11 VS7 11 A B A B 5 5 2-2.6 (Mounting holes for manifold) 10 10 (Lead wire length) 19 19 2-2.6 (Mounting holes for manifold) 300 26.6 26.6 40.6[47.1] 29.5[36] 23 23 17.1 10.5 10.5 10 2-2.6 (Mounting holes) 3 3 11 2-2.6 (Mounting holes) 10 11 15 77.4 15 77.4 [ ] for AC Other dimentions are the same as the grommet style

Dimensions: Pad Unit ZP2-B04MB ZP2-B06MB ZP2-B08MB 4.5 8 8 6 6 3 4 4 2 1.4 1.5 1 2 2 2 2 9 9 9.6 6 4 4 4.6 2.5 2.5 2.5 1.5 3.3 4.7 4.1 6 7 8 4.8 9 8.4 ZP2-B10MB ZP2-B15MB ZP2-B20MB 15 11 10.8 11 7.8 4.6 7.8 4.6 4.6 5.5 3.5 4.5 3.5 3 3.5 13 11 9.5 18 14.4 10.8 9.4 12 6.8 15 20 10 21 16 11 Adapter Mounting Dimensions If an adapter will be made by the customer, design the adapter with the dimensions

Dimensions: Pad Unit ZP2-B04MB ZP2-B06MB ZP2-B08MB 4.5 8 8 6 6 3 4 4 2 1.4 1.5 1 2 2 2 2 9 9 9.6 6 4 4 4.6 2.5 2.5 2.5 1.5 3.3 4.7 4.1 6 7 8 4.8 9 8.4 ZP2-B10MB ZP2-B15MB ZP2-B20MB 15 11 10.8 11 7.8 4.6 7.8 4.6 4.6 5.5 3.5 4.5 3.5 3 3.5 13 11 9.5 18 14.4 10.8 9.4 12 6.8 15 20 10 21 16 11 Adapter Mounting Dimensions If an adapter will be made by the customer, design the adapter with the dimensions

Refer to front matters 42 and 43 for Safety Instructions and pages 3 to 11 for Actuator and Auto Switch Precautions. Mounting Caution Caution Operation 1.