Cooling Capacity: 8 kW, Type: Clean/DI Water, Pump Inverter Control: Pump Inverter Type, Option: C+N+Y+Z
Cooling Capacity: 8 kW, Type: Ethylene Glycol, Pump Inverter Control: Pump Inverter Type, Option: NPT Fitting
Cooling Capacity: 8 kW, Type: Clean/DI Water, Pump Inverter Control: Pump Inverter Type, Option: N+Y
Cooling Capacity: 8 kW, Type: Clean/DI Water, Pump Inverter Control: Pump Inverter Type, Option: C+N
Cooling Capacity: 8 kW, Type: Ethylene Glycol, Pump Inverter Control: None, Option: C+N+Y
Cooling Capacity: 8 kW, Type: Ethylene Glycol, Pump Inverter Control: Pump Inverter Type, Option: C+N+Y
Cooling Capacity: 8 kW, Type: Ethylene Glycol, Pump Inverter Control: Pump Inverter Type, Option: C+N+Y+Z
Cooling Capacity: 8 kW, Type: Clean/DI Water, Pump Inverter Control: Pump Inverter Type, Option: C+N+W
Cooling Capacity: 8 kW, Type: Ethylene Glycol, Pump Inverter Control: Pump Inverter Type, Option: DeviceNet Communication
Model Type: Standard, Piping: H (Immersion Type), Tank Size: 5 (5 inch), Port Size: 06 [3/4 (20A)], Thread Type: F (G), OUT Port Piping: 4 (Pipe Projection: Long; Thread Type: G), Rated Voltage: 5 (24 VDC), Electrical Entry: DZ (DIN Terminal w/Light, w/Surge Voltage Suppressor, All Voltages), Fluid and Ambient Temp.: B (-40 to 60°C)
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
Series: H (High-pressure, Pilot Operated), Size: 3 (30), Valve Type: 1 (N.C.), Main Valve Construction: P (Piston), Body Material: C (Brass), Seal Material: P (Main Valve: PPS; Pilot Valve: PPS), Port Size and Orifice Diameter: 04 (Port: 1/2; Orifice: 12mm), Thread: N (NPT), Rated Voltage: 5 (24 VDC), Electrical Entry: DZ (DIN Terminal w/Light, w/Surge Voltage Suppressor), Option: None
Model Type: Standard, Piping: H (Immersion Type), Tank Size: 8 (8 inch), Port Size: 14 [1 1/2 (40A)], Thread Type: N (NPT), OUT Port Piping: 1 (Pipe Projection: Short; Thread Type: None), Rated Voltage: 5 (24 VDC), Electrical Entry: DZ (DIN Terminal w/Light, w/Surge Voltage Suppressor, All Voltages), Fluid and Ambient Temp.: B (-40 to 60°C), Silencer: S (Silencer)
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, N, HRW, "THERMO CHILLER
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, N, HRW, "THERMO CHILLER, N lb
The HRW series thermo-chiller is a high-performance device for circulating a fluid at a constant temperature (Water-cooled type). Energy saving is substantially increased by exchanging cooling water and heat directly. The HRW can achieve reduction in power consumption as it does not have a compressor, and reduction in the amount of facility water used because heat is exchanged directly
The HRW series thermo-chiller is a high-performance device for circulating a fluid at a constant temperature (Water-cooled type). Energy saving is substantially increased by exchanging cooling water and heat directly. The HRW can achieve reduction in power consumption as it does not have a compressor, and reduction in the amount of facility water used because heat is exchanged directly
reduced facilities investment, space saved facility water facilities, and reduced running cost.Circulating fluids type: fluorinated, ethylene glycol aqueous solution, and clean/DI water, Temperature range setting: 20 to 90 °C, Cooling capacity: 2 kW, 8 kW, 15 kW, and 30 kW, Temperature stability: ±0.3 °C, Ideal for ordinary temperature and high temperature processes, Front Panel for HRW008
Series: 5 (VP500), Pressure Specifications: Standard, 0.7 MPa, Rated Voltage: 5 (24 VDC), Electrical Entry: DZ (with Connector, with Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Type
Series: 7 (VP700), Pressure Specifications: Standard, 0.7 MPa, Rated Voltage: 5 (24 VDC), Electrical Entry: DZ (with Connector, with Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Type