If the product is to be used in an environment containing oils or chemicals such as coolant or cleaning solvent, even for a short time, it may be adversely affected (damage, malfunction, or hardening of the lead wires). Do not use in an area where surges are generated.
An over current error (Er1) is displayed. (1) Check that there is no noise interference such as static electricity, and check for noise sources.
Also install a cleaning device such as an air filter or a mist separator on the secondary side as necessary.
Note 1) An exclusive style set with the maximum bore to only the orifice in the vacuum side can be supplied to user for using with application of high pressure air to the vacuum break port side such as in use of vacuum pad. Refer tp p.4.1-52.
This could cause an auto switch malfunction.
Do not use these values for the thermal set values, etc. *7 Product other than the Option R is not equipped with an earth leakage breaker. Purchase an appropriate earth leakage breaker separately. *8 JIS 10K FF is used as a flange.
When the conduit type is used as equivalent to an IP65 enclosure, install a wiring conduit etc. 7. When an impact, such as water hammer etc., caused by the rapid pressure fluctuation is applied, the solenoid valve may be damaged. Give an attention to it. 3. Air quality
A manual operation mechanism is provided as standard equipment (non-locking). An auto switch cylinder with the switch installed can also be manufactured.
A manual operation mechanism is provided as standard equipment (non-locking). An auto switch cylinder with the switch installed can also be manufactured.
As th r6st oosition is rc', all end-of-stroke valves operated in the rest position have an index zero. Those opratd in the opposlte end (\^,ork position") have an index "1". Fig.
As th r6st oosition is rc', all end-of-stroke valves operated in the rest position have an index zero. Those opratd in the opposlte end (\^,ork position") have an index "1". Fig.
Note) When placing an order for body ported solenoid valve as a single unit, mounting bolt for manifold and gasket are not attached. Order them separately, if necessary.
The standard bowl for the air filter, filter regulator, and lubricator, as well as the sight dome for the lubricator are made of polycarbonate. Do not use in an environment where they are exposed to or come in contact with synthetic oil, organic solvents, chemicals, cutting oil, alkali, and thread lock solutions such as Loctite products. 2.
Use the table as a guideline for mounting.
Never use them in the presence of an explosive gas, as this may cause a serious explosion 2. Do not use in an area where a magnetic field is generated. Auto switches will malfunction or magnets inside cylinders will become demagnetized if used in such an environment. 3. Do not use in an environment where the auto switch will be continually exposed to water. 1.
Caution Single solenoid SJ3000-46-SC-l Double solenoid, 3 position type, 4 position type SJ3000-46-DC-l Connector Assembly Part No.
Type 46 Type S46 Single solenoid coil is located on same side as the A, B port.
The proper tightening torque for the hexagon lock nut is as shown in the table. As a rule, it should be tightened an additional 15 to 30 with a tool after first tightening by hand. Be careful not to cause damage by over tightening.
When the conduit type is used as equivalent to an IP65 enclosure, install a wiring conduit, etc. 9. When an impact, such as water hammer, etc., caused by the rapid pressure fluctuation is applied, the solenoid valve may be damaged.
Use caution, because an external action such as an impacting load, strong vibration or turning force, may damage the locking mechanism or reduce its life. 2. Consider stopping accuracy and the amount of over-run when an intermediate stop is performed.