Values) Horizontal load Note: 1N = 0.2248 lbf 1in = 25.4mm Displacement MGPA32, 40 MGPA12 0.4 0.8 MGPA -400 32 40 32 40 MGPA12-250 MGPA12-250 MGPA -400 0.35 0.7 Plate displacement mm Plate displacement mm 0.3 0.6 MGPA -300 32 40 MGPA -300 32 40 0.25 0.5 MGPA12-150 MGPA12-150 MGPA12-100 MGPA -200 32 40 MGPA12-100 MGPA -200 32 40 0.2 0.4 MGPA12-75 MGPA12-75 MGPA -150 32 40 MGPA -100 32 40
IPX4 (400 V as standard) HRS100/150 Standard type 1.0 5 to 35 V V (400 V as standard, 200 V as an option) HRSH090 Inverter type 0.1 5 to 40 V Indoor use (Only 200 V as an option) (400 V as standard, 200 V as an option) Outdoor installation IPX4 HRSH Inverter type 0.1 5 to 35 V V V V V (Only 200 V as an option.
LEP6 LEP10L LEP10 J K J K J K Low 7 14 12 24 12.5 25 Pushing force [N] Middle 8.5 17 16 32 19 37.5 High 10 20 20 40 25 50 Pushing speed [mm/s] 20 10 20 10 20 10 Pushing force accuracy is 30%F.S. for the LEP6 and 25%F.S. for the LEP10. Refer to the operation manual of the electric actuator for details.
How to Order XB5 Oversized rod cylinder Specifications MB, MB1 CA2 CS1 Series 50, 63 40 50, 63 80 100 125 80 100 Piston rod size (mm) 32 40 140, 160 180, 200 20 16 20 25 30 36 50 25 30 36 60 70 Please contact SMC for dimensions since A, D, H, K, MM, W, ZZ dimensions are different from standard.
K Single shaft S Single shaft T Double shaft Y J Y T S K A parallel key is used instead of single flat for size 40.
CY h + l ZZ + l + Stroke MQQ M Stroke range Bore size (mm) S A AL B B1 C D E F H1 MM K KA M N HX J (mm) 40 50 63 80 100 RHC 30 35 35 40 40 130.6 133.6 140.6 152.6 159.6 27 32 32 37 37 6 7 7 11 11 M14 x 1.5 M18 x 1.5 M18 x 1.5 M22 x 1.5 M26 x 1.5 60 70 86 102 116 22 27 27 32 41 44 52 64 78 92 16 20 20 25 30 32 40 40 52 52 10 10 10 14 14 8 11 11 13 16 14 18 18 22 26 19.4 16.4 18.4 21.4 21.4
AL Z TD TT H1 TX H MM TY B2 D HX A B1 Eh8 F I K NA NN TZ N 8 10 32 41 32 8 18 13 5 52 15.5 13 26 5 57.5 28 M8 x 1.25 15 24 M20 x 1.5 36 20 0 0.033 26 0 0.033 26 0 0.033 32 0 0.039 9 10 40 45 40 10 22 13 5.5 60 19.5 17 32 6 63.5 33.5 M10 x 1.25 15 30 M26 x 1.5 40 9 10 40 45 40 12 22 13 5.5 60 19.5 17 32 6 68 37.5 M10 x 1.25 15 34.5 M26 x 1.5 40 10 11 53 50 53 14 24 16 7 77 21 22 41 8 76 46.5
132 182 230 280 M 76 76 76 86 101 151 199 249 Z 75 75 75 85 100 150 198 248 K 29 39 49 59 69 94 119 144 J 40 40 40 50 60 85 118 155 I 10 10 10 10 15 40 55 68 NN 2 2 2 2 3 4 5 7 H 40 40 40 50 30 35 35 35 G 16 16 16 16 21 26 39 19 N 4 4 4 4 6 6 6 8 HA 40 40 40 50 30 70 70 70 NA 2 2 2 2 2 4 4 4 GA 16 16 16 16 51 61 109 159 KA 125 173 223 13-/22-MXS16L-10 13-/22-MXS16L-20 13-/22-MXS16L-30 13
PROFIBUS DP V1 9.6 k/19.2 k/45.45 k/ 93.75 k/187.5 k/500 k/ 1.5 M/3 M/6 M/12 M 156 k/625 k/2.5 M /5 M/10 M Communication speed [bps] 10 M/100 M 125 k/250 k/500 k Configuration file Note 2) GSD file EDS file EDS file Communication specifications Input 896 points 108 words 4 stations occupied (8 times setting) Input 57 words Output 57 words Input 256 bytes Output 256 bytes Input 200 bytes
S 1 pc. n n pcs. 40 40 mm 50 50 mm 63 63 mm 80 80 mm 100 100 mm * Not available with auto switch. With rod boot/cushion Built-in Magnet Cylinder Model Rod boot Nil Without rod boot J Nylon tarpaulin K Heat resistant tarpaulin If a built-in magnet cylinder without an auto switch is required, there is no need to enter the symbol for the auto switch.
Input/output characteristics chart VEA Communication Specifications (CC, DE, PR, RC) VY1 ITV00-CC CC-Link Ver 1.10 ITV00-DE DeviceNet Volume1 (Edition3.8), Volume3 (Edition1.5) ITV00-PR PROFIBUS DP DP-V0 ITV00-RC RS-232C Model VBA VBAT Protocol Version Note 1) 156 k/625 k 2.5 M/5 M/10 M bps 125 k/250 k/500 k bps 9.6 k/19.2 k/45.45 k 93.75 k/187.5 k/500 k 1.5 M/3 M/6 M/12 M bps 9.6 kbps Communication
With head end pin hole Specifications Applicable series MK2T 32, 40, 50, 63 Bore size Same as standard product Specifications other than above Dimensions Head end pin hole 3.3 depth 3 +0.15 +0.05 L K Bore size (mm) K L 40 32 9 0.15 8 0.15 7 0.15 7 0.15 24 0.15 20 0.15 63 50 35 0.15 30 0.15 Dimensions other than above are same as basic type. 40 Series MK/MK2/MK2T Safety Instructions These
14 NY M4 x 0.7 8 70 50 5 46 69.8 61.4 M4 x 12 M5 x 40 11 NX M5 x 0.8 9 63 50 5 49.7 69.8 61.4 M4 x 12 M5 x 40 9 NW M5 x 0.8 9 70 50 5 47.5 69.8 61.4 M4 x 12 M5 x 40 9 NV M4 x 0.7 8 63 50 5 49.7 69.8 61.4 M4 x 12 M5 x 40 9 NU M5 x 0.8 9 70 50 5 47.5 69.8 61.4 M4 x 12 M5 x 40 11 NT M5 x 0.8 9 70 50 5 46 69.8 61.4 M3 x 12 M5 x 40 12 NM2 M4 x 0.7 8 50 36* 4.5* 40.1 69.8 61.4 M4
G G 4 x J Width across flats KA MM RY D E d e C B H1 10.2 L f B1 AL h + L C B A K ZZ + L + Stroke F N RT N M S + Stroke H ZZ + Stroke (mm) M Bore size Stroke range AL B B1 C D E F G H1 J K KA (mm) A (mm) Without reinforcement ring With reinforcement ring 40 50 63 80 30 35 35 40 40 27 32 32 37 37 60 70 85 22 27 27 32 41 44 52 64 78 92 16 20 20 25 30 32 40 40 52 52 10 10 10 14 14 15 17 17 21
Install a diode (D) for an inductive load, or install an inrush current suppressing resistor (R) for a lamp load. (Rated current: 40 mA or less, maximum current: 50 mA or less, inrush current: 100 mA or less) A maximum of 5.2 V voltage drop occurs in the driver.
to 45 1 to 60 0.9 to 75 0.8 to 90 0.7 400K 8cos + 2 (5.1 + Lo) sin 40 Angle coefficient (k): k = [to 45 (= )] = 1, [to 60] = 0.9, [to 75] = 0.8, [to 90] = 0.7 Lo: Distance from mounting surface to load center of gravity (cm) 20 36 2.9 + Lo 10 5.25 2.2 + Lo 15 17.5 2.7 + Lo Bore size (mm) Allowable load weight WA (kg) 32 25 105 4.2 + Lo 60 3.4 + Lo 40 200 5.1 + Lo Bore size (mm) 5.
Standard Stroke Model Standard stroke (mm) 10, 20, 30, 40, 50 MXQ6 10, 20, 30, 40, 50, 75 MXQ8 10, 20, 30, 40, 50, 75, 100 MXQ12 10, 20, 30, 40, 50, 75, 100, 125 MXQ16 10, 20, 30, 40, 50, 75, 100, 125, 150 MXQ20 10, 20, 30, 40, 50, 75, 100, 125, 150 MXQ25 8-5-9 10 Series MXQ Theoretical Output IN OUT The dual rod ensures an output twice that of existing cylinders.
40 Angle coefficient (k): k = [up to 45 (= )] = 1, [up to 60] = 0.9, [up to 75] = 0.8, [up to 90] = 0.7 Lo: Distance from mounting surface to load center of gravity (cm) 20 36 2.9 + Lo 10 5.25 2.2 + Lo 15 17.5 2.7 + Lo Bore size (mm) Allowable load mass WA (kg) 5.
Never use in an atmosphere of explosive gases. The construction of auto switches is not intended to prevent explosion. Never use in an atmosphere with an explosive gas since this may cause a serious explosion. 2. Do not use in an area where a magnetic field is generated. Auto switches will malfunction or magnets inside actuators will become demagnetized. 3.