Note 3) ZP3-(015/02/035)U ZP3-Y(015/02/035)U;(J/K)3-@ ZP3-Y(015/02/035)U;(J/K)6-@ ZP3B-Y1(J/K)3-B3 ZP3B-Y1(J/K)6-B3 ZP3-Y(10/13/16)UM;(J/K)3-@ ZP3-Y(10/13/16)B;(J/K)3-@ ZP3-Y(10/13/16)UM;(J/K)6-@ ZP3-Y(10/13/16)B;(J/K)6-@ ZP3-Y(10/13/16)UM;(J/K)10-@ ZP3-Y(10/13/16)B;(J/K)10-@ ZP3-Y(10/13/16)UM;(JB/K)15-@ ZP3-Y(10/13/16)B;(JB/K)15-@ ZP3-Y(10/13/16)UM;(JB/K)20-@ ZP3-Y(10/13/16)B;(JB/K)20-@
1 k Load OUT1 (Black) OUT2 (White) 12 to 24 VDC 12 to 24 VDC Load Load DC () (Blue) DC () (Blue) ZSE40(F) ISE40--30(L)-(M) With auto shift input ZSE40(F) ISE40--70(L)-(M) With auto shift input DC (+) (Brown) Auto shift input (Gray) OUT1 (Black) OUT2 (White) DC (+) (Brown) Auto shift input (Gray) 1.2 k 1.2 k Load 6.8 k 6.8 k Main circuit Main circuit Load OUT1 (Black) OUT2 (White) 12 to 24
Load rate Ea= K E max Ea=1 0.11=0.11 Work mounting coeficient K: Fig.3 Max. allowable kinetic energy Emax: Table 1 Kinetic energy (E)Allowable kinetic energy (Ea) Possible to use by E=0.0 3 3-1 Load rate of work Calculate static work Wa (N) Wa=1 X 1 X 4=4 K=1 b=1 Wmax=4 a1=1/4=0.25 Wa=K b Wmax Work mounting coeficient K: Fig.3 Allowable load coeficient b: Graph 1 Max.
Width across flats KB B C V MM BH1 BH2 BH3 TX D E B1 C B ZZ + Stroke S + Stroke H A K BN N1 N MA MB F AL H1 TT B C B1 C B TY With rod boot d e 10.2 f h 10.2 l [mm] Bore size A AL B B1 BH1 BH2 BH3 BN BP C D E F GA GB GC GD GE GF H H1 J 32 22 19.5 46 46 23 38.5 46.5 59 1/8 32.5 12 30 13 37.5 13 37.5 18.5 4 13 47 6 M6 x 1.0 40 30 27 57 52 28.5 42.5 48.5 73 1/8 38 16 35 13 59.5 14 44.5 19.5 4
J 70C Nylon tarpaulin K 110C* Neoprene cloth * Maximum ambient temperature for the rod boot only. Mounting Bracket Part No.
Assembly of a piston and a seal (KSYP-13). 454 Regulator AR10-A to AR40-A Series Dimensions AR10-A to AR40-06-A 2 x P1 (Port size) J A AC-A AF-A B C AF-A OUT IN H AR-A AR-A V AL-A Q AW-A (Pressure gauge port size) Pressure gauge (Option) 2 x P2 AC-B R S AF-A F AF-A U D Bracket (Option) AR -A -B N J M T AL-A AW -A -B Panel fitting dimensions AW Y AG W E AV IN OUT AF Z Plate thickness AR10-
Description Body class Symbol Bracket assembly LQ-GBL J K 1, 2 J type K type 1, 2, 3, 4, 5, 6 L M L type M type (for short piping) Table 1 Tubing size symbols Replacement parts Tubing O.D. Metric sizes Tubing outside diameter Part No.
JIS Symbol 15-9-19 2 Series AS How to Order 2 2 1 U02 06 K AS 1F Nil Option Body size 2 3 4 1/8, 1/4 standard 3/8 standard 1/2 standard None Hexagonal lock nut Electroless nickel plated K N If more than one option is required, write option part numbers in the order of K, N. Applicable tubing O.D.
For further details, refer to mounting positions under Replacement heaters/Part Nos. on page 46. 24 High Vacuum Angle Valve Series XLD, XLDV Dimensions (mm) 1in=25.4mm XLDV-25/With solenoid valve 11 C Fn (KF flange) Fb (K flange) C Port R (exhaust port) K K 2.5 41.5 Initial exhaust solenoid valve Main exhaust solenoid valve G A B 8 10.5 Port P (pressure port) A Max 10.5 (except connector
IDX-OM-W035-B / Series IDFB22E-11 IDFB22E-11 K,R,S,T,V IDFB22E-23 IDFB22E-23 K,R,T,V IDFB37E-23 IDFB37E-23 K,R,T,V IDFB55E-46 IDFB55E-46 L,R,T,V IDFB75E-46 IDFB75E-46 L,R,T,V URLhttps://www.smcworld.com/ English instruction manual can be downloaded from our URLhttps://www.smcworld.com/ SMC () * 1 ) JIS B8370 * 2 ) ISO4414 *1) ISO4414Pneumatic fluid power General rules and safety requirements
For HRR050-AF-20/40G thread adapter set 1 set For HRR050-AN-20/40NPT thread adapter set 1 set 1 In the case of option Z, not included.
L k Imaginary stroke L' = (Stroke) + k + L k: Distance between the center and the end of the plate 20 6mm 25 32 8mm (Example) When using CXSM20-10 and L = 10mm: Imaginary stroke L' = 10 + 6 + 10 = 26 Therefore, the graph used for your model selection should be the one for CXSM20-30 ( , ). 61 Series CXS Vertical Mounting [based on maximum speed (V)] Graph V = up to 200mm/s 1 Graph V = up to
A XLAV: Air operated, With solenoid valve J N M Port 1(P) K L Port 3(R) Solenoid valve [mm] Model J K L M N XLAV-16-2 41 17.2 10.2 3.6 3.6 XLAV-25-2 46 21.4 10.2 3.6 3.6 XLAV-40-2 54.5 33.9 10.2 3.6 3.6 XLAV-50-2 61 38.2 10.2 3.6 3.6 XLAV-63-2 80.5 43.8 12 4 2 XLAV-80-2 90.5 59.8 12 4 2 6 A Aluminum High Vacuum Angle Valve Double Acting, Bellows Seal RoHS XLC Series How to Order q w e r t
K Hose nipple M Tube H Barb Possible for combination use of nylon tubing and polyurethane tubing. Configuration for easy insertion into the tube Holds the tube tightly.
Description Body class Symbol LVC LVA Bracket assembly LQ-GBL LVH J, K 1, 2 LVD J type K type LVQ LQ 1, 2, 3, 4, 5, 6 L, M LVN L type M type (for short piping) TI/ TIL Table 1 Tubing size symbols Part No. Description Replacement parts PA Tubing O.D.
For further details, refer to mounting positions under Replacement heaters/Part Nos. on page 46. 24 High Vacuum Angle Valve Series XLD, XLDV Dimensions (mm) 1in=25.4mm XLDV-25/With solenoid valve 11 C Fn (KF flange) Fb (K flange) C Port R (exhaust port) K K 2.5 41.5 Initial exhaust solenoid valve Main exhaust solenoid valve G A B 8 10.5 Port P (pressure port) A Max 10.5 (except connector
S 3 0 7 0 L 2 Q K 7 1 5 . 8 4 9 4 9 6 8 / 1 S 1 0 9 0 L 2 Q K 2 1 2 . 5 1 2 1 5 . 3 2 5 . 3 4 7 4 5 . 8 1 6 0 3 6 1 / 5 4 / 1 S 2 0 9 0 L 2 Q K 4 1 5 . 9 4 1 5 7 4 8 / 3 S 3 0 9 0 L 2 Q K 7 1 5 . 1 5 3 5 4 7 4 / 1 S 2 0 1 1 L 2 Q K 7 1 9 . 7 1 7 1 5 . 5 2 6 5 9 5 1 2 7 9 6 8 / 3 8 / 3 S 3 0 1 1 L 2 Q K 8 5 1 6 6 7 2 / 1 S 4 0 1 1 L 2 Q K 2 2 5 . 4 6 5 . 5 6 7 4 1 R(PT) 4 / 1 S 2 0 3 1 L 2
Conduit DIN terminal Electrical entry Mounting dimensions Bracket mounting Port size P Model Orifice size A B C D E F H Conduit terminal J M4 M5 M5 M5 M5 K M Q R 50 60 63 66 70 Q 40 R Q 58 R S 46 Q 95 R S 62 T U 46 56 56 W X 11 13 13 Y Normally closed Normally open VX212 VX222 VX232 VX210 VX220 VX220 VX230 VX230 1/8, 1/4 1/4, 3/8 1/4, 3/8, 1/2 1/4, 3/8 1/4, 3/8, 1/2 18 22 30 22 30 (