Cooling Method: Air-cooled Refrigeration, Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: Applicable to Deionized Water Piping
Cooling Method: Air-cooled Refrigeration, Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: w/Automatic Fluid Fill Function
Cooling Method: Air-cooled Refrigeration, Pipe Thread: F [G (w/Rc-G Conversion Fitting)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: Applicable to Deionized Water Piping
Cooling Method: Air-cooled Refrigeration, Pipe Thread: F [G (w/Rc-G Conversion Fitting)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: SI Unit Only
Cooling Method: Air-cooled Refrigeration, Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: B + J
Cooling Method: Air-cooled Refrigeration, Pipe Thread: F [G (w/Rc-G Conversion Fitting)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: w/Earth Leakage Breaker
Cooling Method: Water-cooled Refrigeration, Pipe Thread: Rc, Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: B + J
Cooling Method: Air-cooled Refrigeration, Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: SI Unit Only
Cooling Method: Air-cooled Refrigeration, Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: B + J + M
Cooling Method: Air-cooled Refrigeration, Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: B + M + W
Cooling Method: W (Water-cooled Refrigeration), Pipe Thread: F [G (w/Rc-G Conversion Fitting)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: M (Applicable to Deionized Water Piping)
Cooling Capacity: 9 kW, Piping thread type: Rc, Optional specifications: Compatible with deionized water (pure water) piping
Thermo-chiller HRS offers convenient functions, self diagnosis and check display for easy maintenance. An angled supply port facilitates the supply of circulating fluid, even when units are stacked. A large digital display provides a clear view of the current and set values. The dustproof filter is integrated with the grill of the front panel allowing mounting and removal of the HRS filter
Cooling Method: W (Water-cooled Refrigeration), Pipe Thread: Rc, Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: BW (B + W)
Cooling Method: W (Water-cooled Refrigeration), Pipe Thread: Rc, Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: BM (B + M)
Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: F [G (w/Rc-G Conversion Fitting)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: J (w/Automatic Fluid Fill Function)
to 500 30 27 60 22 44 16 32 10 15 8 M8 x 1.25 6 14 40 +0.070 0 0.1 0.3 12 18.0 up to 600 20 to 600 35 32 70 27 52 20 40 10 17 11 M8 x 1.25 7 18 50 +0.070 0 0.1 0.3 16 25.0 up to 600 20 to 600 35 32 85 27 64 20 40 10 17 11 M10 x 1.25 7 18 63 +0.084 0 0.1 0.3 20 31.5 102 13 up to 750 20 to 750 40 37 32 78 25 52 14 21 M12 x 1.75 10 22 80 +0.084 0 0.1 0.3 25 35.5 100 up to 750 20 to 750 40 37
/300-A-40. 8-9 8.2.4 HRSH100/150/200/250-W-20/40. 8-10 8.3 Flow Diagram . 8-11 8.3.1 HRSH-A-20/40. 8-11 8.3.2 HRSH-W-20/40. 8-12 8.4 Cooling Capacity . 8-13 8.4.1 HRSH100-A-20/40. 8-13 8.4.2 HRSH150-A-20/40. 8-13 8.4.3 HRSH200-A-20/40. 8-14 8.4.4 HRSH250-A-20/40. 8-14 8.4.5 HRSH300-A-20/40. 8-15 8.4.6 HRSH100-W-20/40. 8-16 8.4.7 HRSH150-W-20/40. 8-16 8.4.8 HRSH200-W-20/40. 8-17 8.4.9 HRSH250
-W-20/40/46. 8-11 8.4 Cooling capacity . 8-12 HRS Series HRX-OM-S004 Contents 8.4.1 HRS100-A-20/40/46. 8-12 8.4.2 HRS150-A-20/40/46. 8-12 8.4.3 HRS100-W-20/40/46. 8-13 8.4.4 HRS150-W-20/40/46. 8-13 8.5 Pump capacity . 8-14 8.5.1 HRS100/150-A/W-20/40/46. 8-14 8.6 Types of Hazard Labels (HRS--40/46-) . 8-15 8.6.1 Positions of danger warning label . 8-16 8.7 Standards . 8-17 8.8 Sample DoC.