Cooling Capacity: 030 [2500/3000, (50/60 Hz)], Cooling Method: Water-cooled, Pipe Thread: F [G (w/Rc-G Conversion Fitting Set)], Option 1: Applicabe to DI Water Piping, Option 2: -
Cooling Capacity: 018 [1600/1800, (50/60 Hz)], Cooling Method: Water-cooled, Pipe Thread: F [G (w/Rc-G Conversion Fitting Set)], Option 1: None, Option 2: -
Cooling Capacity: 030 [2500/3000, (50/60 Hz)], Cooling Method: Water-cooled, Pipe Thread: F [G (w/Rc-G Conversion Fitting Set)], Option 1: M + T, Option 2: -
Cooling Capacity: 030 [2500/3000, (50/60 Hz)], Cooling Method: Water-cooled, Pipe Thread: F [G (w/Rc-G Conversion Fitting Set)], Option 1: w/Electric Conductivity Control Function, Applicable to DI Water Piping, Option 2: -
Cooling Capacity: 050 [5000/5900, (50/60 Hz)], Cooling Method: Water-cooled, Pipe Thread: F [G (w/Rc-G Conversion Fitting Set)], Option 1: w/Electric Conductivity Control Function, Applicable to DI Water Piping, Option 2: -
Cooling Capacity: 15.7kW, Thread: G, w/Rc-G Conversion Fitting, Option: B+K
Cooling Capacity: 11.5kW, Thread: G, w/Rc-G Conversion Fitting, Option: A + K
Cooling Capacity: 11.5kW, Thread: G, w/Rc-G Conversion Fitting, Option: Conforming to CE/UL Standards
Cooling Capacity: 25kW, Thread: G, w/Rc-G Conversion Fitting, Option: M + S + T
the front panel allowing mounting and removal of the HRS filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, Thermo-chiller, water cooled, HRS090
the front panel allowing mounting and removal of the HRS filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, Thermo-chiller, water cooled, HRS090
the front panel allowing mounting and removal of the HRS filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, Thermo-chiller, water cooled, HRS090
the front panel allowing mounting and removal of the HRS filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, THERMO-CHILLER, WATER COOLED, HRS090
Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: Rc, Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: B (w/Earth Leakage Breaker)
Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: Rc, Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: BJ (B + J)
Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: Rc, Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: M (Applicable to Deionized Water Piping)
Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: B (w/Earth Leakage Breaker)
Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: BM (B + M)
Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: JM (J + M)
Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: M (Applicable to Deionized Water Piping)