Cooling Capacity: 012 (Cooling Capacity: 1100/1300W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: F (G w/PT-G Conversion Fitting Set)
Cooling Capacity: 012 (Cooling Capacity: 1100/1300W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set)
Cooling Capacity: 012 (Cooling Capacity: 1100/1300W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set)
Cooling Capacity: 012 (Cooling Capacity: 1100/1300W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: Rc
Cooling Capacity: 012 (Cooling Capacity: 1100/1300W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: Rc
Type: Thermo-Chiller, Cooling Method: Air-Cooling, Cooling Capacity: 1,100/1,300 W (50/60 Hz), Piping thread type: Rc, Optional specifications: None
Type: Thermo-Chiller, Cooling Method: Air-Cooling, Cooling Capacity: 1,100/1,300 W (50/60 Hz), Piping thread type: NPT (PT-NPT conversion fitting set included), Optional specifications: None
Type: Thermo-Chiller, Cooling Method: Water Cooling, Cooling Capacity: 1,100/1,300 W (50/60 Hz), Piping thread type: Rc, Optional specifications: None
Type: -, Cooling Method: -, Cooling Capacity: 1,100/1,300 W (50/60 Hz), Piping thread type: NPT (PT-NPT conversion fitting set included), Optional specifications: None
Cooling Capacity: Cooling Capacity: 1100/1300W, 50/60 Hz, Cooling Method: Water-cooled Refrigeration, Thread: G w/PT-G Conversion Fitting Set, Option: -
NBR Silicon rubber NBR Silicon rubber NBR Silicon rubber NBR Silicon rubber NBR Silicon rubber NBR Silicon rubber ZP02 ZP04 ZP06 ZP08 ZP10 ZP13 ZP16 ZP20 ZP25 ZP32 ZP40 ZP50 ZP63 ZP80 ZP100 ZP125 5 7 8 2 2 4 4 7 9 11 2 4 5 7 10 4 6 8 10 5 5 10 10 7 9 9 10 13 10 8 13 11 13 11 10 11 16 20 25 32 12 14 9 9 13 15 19 25 33 13 15 20 26 35 14 17 20 24 30 15 18 21 26 33 14 14 13 20 18 12 13 11 17
(Rated voltage 125 V, Plug JIS C 8303, Inlet IEC 60320-C13) *1 Measured with a high pressure probe of 1000 M and 5 pF *2 Measurement value based on a charged plate (Dimensions: 150 mm x 150 mm, Capacitance: 20 pF) as defined in the U.S.
11.4 5.2 16.4 27 10 23 16 37.8 23 6 18 12 0.02 0.02 0.05 112211221122MHZ2-16D 5 15 67.3 8 11 38 16 6.5 23.6 30 13 30.6 24 42.5 24.5 7.5 22 15 0.02 0.02 0.05 MHZ2-20D 8 18 84.8 10 16.8 50 18.6 7.5 27.6 35 15 42 30 52.8 29 9.5 32 20 0.02 0.02 0.05 MHZ2-25D 102.7 63 33.6 52 63.6 11 25 10 12 22 36.5 36 30 40 22 21.8 10 20 0.02 0.02 0.05 U V W X Y Z AA AB AC AD AE AF AG AH AJ AK Model 1122+0.043
Port size AV o s AU Drain Min. clearance for maintenance 45 AF A AR AFD30/40/40-06 L Bracket (Option) D A G IR F K M J C VEX AFD30: 50 AFD40: 75 B E IN OUT AMR H OUT ITV Port size IC VBA P Drain Min. clearance for maintenance VE VY1 G AFD20 AFD30, AFD40, AFD40-06 Drain cock with barb fitting With drain guide With compact auto-drain (N.C.) With auto-drain (N.O./N.C.)
Mist Separator Series AFM20/30/40 How to Order F 30 AFM Option 03 BD 2R Description Applicable model Symbol Mist separator 2 Accessory Metal bowl AFM20 to 40 Body size 6 Applicable model Description Symbol Nylon bowl AFM20 to 40 Port size 20 30 40 8 Nil Metal bowl with level gauge AFM30/40 (3) C Body size With bracket B AFM20 to 40 With bowl guard Port size AFM20 Thread type Symbol 20 30
710 670 20 700 230 120 222 2 1 14-13-14
710 670 20 700 230 120 222 2 1 14-13-14
Tubing for AD27-D: I.D. 2.5 (3/32") or larger, Length 5 m (200 inch) or shorter Tubing for AD37, 47(N)-D: I.D. 4 (3/16") or larger, Length 5 m (200 inch) or shorter Tubing for AD38, 48(N)-D: I.D. 6.5 (1/4") or larger, Length 5 m (200 inch) or shorter Air Source Warning (1) Use clean air.
Tubing for AD27-D: I.D. 2.5 (3/32") or larger, Length 5 m (200 inch) or shorter Tubing for AD37, 47(N)-D: I.D. 4 (3/16") or larger, Length 5 m (200 inch) or shorter Tubing for AD38, 48(N)-D: I.D. 6.5 (1/4") or larger, Length 5 m (200 inch) or shorter Air Source Warning (1) Use clean air.
(Recommended tightening torque:0.5 to 0.75 N m) 17 2-1. Piston Rod Movement Direction (DIP Switch No. 1) The piston rod movement direction relative to the analogue input signal (4-20 mA) can be set, for when the target position operation is performed.