Cooling Capacity: 018 [1600/1800, (50/60 Hz)], Cooling Method: W (Water-cooled), Pipe Thread: Rc, Option 1: None, Option 2: Y (w/Feet and No Rack Mounting Brackets)
Cooling Capacity: 024 [2000/2400, (50/60 Hz)], Cooling Method: W (Water-cooled), Pipe Thread: Rc, Option 1: None, Option 2: Y (w/Feet and No Rack Mounting Brackets)
Cooling Capacity: 030 [2500/3000, (50/60 Hz)], Cooling Method: W (Water-cooled), Pipe Thread: Rc, Option 1: None, Option 2: Y (w/Feet and No Rack Mounting Brackets)
Cooling Capacity: 012 [1000/1200, (50/60 Hz)], Cooling Method: W (Water-cooled), Pipe Thread: Rc, Option 1: MT (M + T)
Cooling Capacity: 010 [1000/1100, (50/60 Hz)], Cooling Method: W (Water-cooled), Pipe Thread: Rc, Option 1: MT1 (M+T1)
Cooling Capacity: 012 [1000/1200, (50/60 Hz)], Cooling Method: W (Water-cooled), Pipe Thread: Rc, Option 1: M (Applicabe to DI Water Piping)
Cooling Capacity: 010 [1000/1100, (50/60 Hz)], Cooling Method: W (Water-cooled), Pipe Thread: Rc, Option 1: T1 (Inverter Pump Mounted)
Cooling Capacity: 010 [1000/1100, (50/60 Hz)], Cooling Method: W (Water-cooled), Pipe Thread: Rc, Option 1: None
Cooling Capacity: 018 [1600/1800, (50/60 Hz)], Cooling Method: W (Water-cooled), Pipe Thread: Rc, Option 1: T1 (Inverter Pump Mounted)
Cooling Capacity: 018 [1600/1800, (50/60 Hz)], Cooling Method: W (Water-cooled), Pipe Thread: Rc, Option 1: T (High-pressure Pump Mounted)
Cooling Capacity: 024 [2000/2400, (50/60 Hz)], Cooling Method: W (Water-cooled), Pipe Thread: Rc, Option 1: T1 (Inverter Pump Mounted)
Cooling Capacity: 024 [2000/2400, (50/60 Hz)], Cooling Method: W (Water-cooled), Pipe Thread: Rc, Option 1: T (High-pressure Pump Mounted)
Cooling Capacity: 012 [1000/1200, (50/60 Hz)], Cooling Method: W (Water-cooled), Pipe Thread: Rc, Option 1: T (High-pressure Pump Mounted)
Cooling Method: W (Water-cooled Refrigeration), Pipe Thread: Rc, Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: M (Applicable to Deionized Water Piping)
Cooling Method: W (Water-cooled Refrigeration), Pipe Thread: Rc, Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: JM (J + M)
Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: F [G (w/Rc-G Conversion Fitting)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: W (SI Unit Only)
Cooling Method: W (Water-cooled Refrigeration), Pipe Thread: Rc, Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: BJ (B + J)
Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: W (SI Unit Only)
Cooling Capacity: 090 (9.5 kW Air/ 11.0kW Water), Cooling Method: W (Water-cooled Refrigeration), Power Supply: 20 [3-phase 200VAC (50 Hz); 3-phase 200 to 230VAC (60 Hz)], Option: CM (Compressor Inverter + Applicable to DI Water Piping)
Thermo-chiller HRS offers convenient functions, self diagnosis and check display for easy maintenance. An angled supply port facilitates the supply of circulating fluid, even when units are stacked. A large digital display provides a clear view of the current and set values. The dustproof filter is integrated with the grill of the front panel allowing mounting and removal of the HRS filter