Please contact us for the latest version.sales@ocaire.com, FITTING *LQA, CONNECTORS, KQ ONE TOUCH FITTING, KL, KQ 3/8, 0.2112 lb

Body/Exhaust Type: C (For Manifold - Common Silencer Exhaust), Nominal Nozzle Size: 10 (ø1.0), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: H (Digital Pressure Switch for Vacuum / -100 to 100 kPa / PNP 2 Outputs), Connector: C1 [Common Wiring (plug-in) - w/o Lead Wire with Connector - w/o Lead Wire with Connector for Pressure Switch/sensor], Vacuum

Body/Exhaust Type: F (For Manifold - Individual Port Exhaust), Nominal Nozzle Size: 10 (ø1.0), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: P (Pressure Sensor / 0 to -101 kPa / Analogue Output 1 to 5 V), Connector: C [Common Wiring (plug-in) - w/o Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port

Body/Exhaust Type: H (For Manifold - High-noise Reduction Silencer Exhaust), Nominal Nozzle Size: 15 (ø1.5), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: C (Digital Pressure Switch for Vacuum / 0 to -101 kPa / PNP 2 Outputs), Connector: C [Common Wiring (plug-in) - w/o Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/

Body/Exhaust Type: For Manifold - Common Silencer Exhaust, Nominal Nozzle Size: ø1.0, Supply Valve and Release Valve: N.C. / N.C., Rated Voltage: 24 VDC, Vacuum Sensor: Digital Pressure Switch for Vacuum / -100 to 100 kPa / PNP 2 Outputs, Connector: C1 [Common Wiring (plug-in) - w/o Lead Wire with Connector - w/o Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 07 [ø1

Body/Exhaust Type: For Manifold - Individual Port Exhaust, Nominal Nozzle Size: ø1.0, Supply Valve and Release Valve: N.C. / N.C., Rated Voltage: 24 VDC, Vacuum Sensor: Pressure Sensor / 0 to -101 kPa / Analogue Output 1 to 5 V, Connector: C [Common Wiring (plug-in) - w/o Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 07 [ø1/4 One-touch

Body/Exhaust Type: For Manifold - High-noise Reduction Silencer Exhaust, Nominal Nozzle Size: ø1.5, Supply Valve and Release Valve: N.C. / N.C., Rated Voltage: 24 VDC, Vacuum Sensor: Digital Pressure Switch for Vacuum / 0 to -101 kPa / PNP 2 Outputs, Connector: C [Common Wiring (plug-in) - w/o Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port

Please contact us for the latest version.sales@ocaire.com, TERMINAL BOLT 1.5 LONG 3/8X3/8, CONNECTORS, KV FITTING, D.O.T., KL, KV 3/8, 0.38011 lb

Body Size: 60, Type: Regulator Type, Pipe Thread: NPT, Port Size: 1, Normally Open, Closed: N.O., Normally Open, Protocol: SA [Standalone (When Wireless Adapter is Connected: Wireless Remote)], Unit: EXA1/ITV: Units Selection Function, Manual Override: Non-locking Push Type

Body Size: 60, Type: Regulator Type, Pipe Thread: G, Port Size: 3/4, Normally Open, Closed: N.C., Normally Closed, Protocol: SA [Standalone (When Wireless Adapter is Connected: Wireless Remote)], Unit: EXA1/ITV: Units Selection Function, Manual Override: Non-locking Push Type

Body Size: 60, Type: Regulator Type, Pipe Thread: G, Port Size: 1, Normally Open, Closed: N.C., Normally Closed, Protocol: SA [Standalone (When Wireless Adapter is Connected: Wireless Remote)], Unit: EXA1/ITV: Units Selection Function, Manual Override: Non-locking Push Type

Body Size: 60, Type: Regulator Type, Pipe Thread: G, Port Size: 1, Normally Open, Closed: N.O., Normally Open, Protocol: SA [Standalone (When Wireless Adapter is Connected: Wireless Remote)], Unit: EXA1/ITV: Units Selection Function, Manual Override: Non-locking Push Type

Body Size: 60, Type: Regulator Type, Pipe Thread: NPT, Port Size: 3/4, Normally Open, Closed: N.C., Normally Closed, Protocol: SA [Standalone (When Wireless Adapter is Connected: Wireless Remote)], Unit: EXA1/ITV: Units Selection Function, Manual Override: Non-locking Push Type

Body Size: 60, Type: Regulator Type, Pipe Thread: Rc, Port Size: 3/4, Normally Open, Closed: N.C., Normally Closed, Protocol: SA [Standalone (When Wireless Adapter is Connected: Wireless Remote)], Unit: EXA1/ITV: Units Selection Function, Manual Override: Non-locking Push Type

Body Size: 60, Type: Regulator Type, Pipe Thread: Rc, Port Size: 1, Normally Open, Closed: N.C., Normally Closed, Protocol: SA [Standalone (When Wireless Adapter is Connected: Wireless Remote)], Unit: EXA1/ITV: Units Selection Function, Manual Override: Non-locking Push Type

Body Size: 60, Type: Regulator Type, Pipe Thread: Rc, Port Size: 1, Normally Open, Closed: N.O., Normally Open, Protocol: SA [Standalone (When Wireless Adapter is Connected: Wireless Remote)], Unit: EXA1/ITV: Units Selection Function, Manual Override: Non-locking Push Type

Body Size: 60, Type: Regulator Type, Pipe Thread: NPT, Port Size: without Attachments, Normally Open, Closed: N.O., Normally Open, Protocol: SA [Standalone (When Wireless Adapter is Connected: Wireless Remote)], Unit: EXA1/ITV: Units Selection Function, Manual Override: Non-locking Push Type