Standard Stroke Standard stroke (mm) Bore size (mm) Max. stroke 32 700 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500 40 800 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500 50 1200 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600 Made to Order Specifications (For details, refer to page 6-17-19.) 63 1200 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600 80 1400 25, 50,
/s) 50 1200 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 C85 -XC3 Special port location 63 1200 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 -XC4 With heavy duty scraper 80 1400 C95 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 Heat resistant cylinder (110 C) -XC5 100 1500 25, 50, 75, 100, 125, 150, 175
nut made of stainless steel 25, 50, 75, 100, 125, 150, 175, 200, 250, XC8 XC9 XC14 XC15 XC22 Adjustable stroke/Extension adjustment 1 50, 63 300, 350, 400, 450, 500, 600 2 Adjustable stroke/Retraction adjustment 25, 50, 75, 100, 125, 150, 175, 200, 250, Change of trunnion bracket mounting position 80, 100 300, 350, 400, 450, 500, 600, 700 Change of tie-rod length Types with auto switch
Operating speed Make sure to connect a speed controller to the cylinder and adjust its speed to 500 mm/s or less. If a load is to be attached to the end of the rod, adjust the speed to the maximum speed shown in Graph (1) or less, in accordance with the added mass.
Replacement Parts: Seal Kits 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 50, 63 Bore size (mm) Contents Kit No. 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700 80, 100 40 50 63 80 100 CA2Y40-PS Rod seal 1 pc.
MRQ Mass Rotating angle Size Basic mass (g) Flange (g) Add'l stroke mass (g/mm) 80 to 100 1400 4 500 32 170 to 190 1500 80 to 100 2100 40 5 500 170 to 190 2300 Calculation: (Example) MRQBS32-50CA Basic mass 1400 g 4 x 50 = 200 g Stroke additional mass Total 1600 g For the mass of auto switch alone, refer to pages 767 to 809.
Built-in magnet for auto-switches CV MVGQ Maximum Driving Speed of Cylinders 1000 1000 900 900 Cylinder speed (mm/s) Cylinder speed (mm/s) 800 800 Load factor: 10% Load factor: 50% 700 700 600 600 500 500 400 400 300 300 200 200 100 100 0 12 16 20 25 32 40 50 63 80 100 0 SYJ3000 VZ3000 VZ5000 VF3000 Bore size (mm) Series Variations Bore size (mm) Standard stroke (mm) Applicable valve series
B0.2 2d or more 0.1 MGJ MGP MGQ 0.01 100 500 400 300 200 MGG Max. speed (mm/s) MGQ without a cushion (XB6, XC22) MGC D C0.2 1000 By-pass port dia.
Clean Room Rodless Cylinder Series CYP 15, 32 How to Order MX CYP 15 Z73 200 MTS MY Number of auto switches Nil S n 2 pcs. 1 pc. n pcs. CY MG Bore size 15 32 15 mm 32 mm CX Auto switch Nil Without auto switch DFor the applicable auto switch model, refer to the table below.
A / Four types of mounting are possible Knock pin holes provided on each mounting surface make positioning easy 34 35 38 40 50 63 Top mount Side mount (1in = 25.4mm) A Body length Application examples Drop prevention for a upward facing cylinder Holding a clamped condition Retraction is locked Retraction is locked T-slot side mount Bottom mount LOCK LOCK Series MLGP How to Order MLGP M Z73
Applicable model: D-A73, A73H, A73C, A93, A93V, A53, A54, B53, B54, C73, C73C, E73A, Z73, D-R73, R73C, 97, 93A, A33, A34, A33A, A34A, A44, A44A 2) When using a 2-color indicator type auto switch (D-A79W, A59W and B59W), the auto switch will constantly remain ON if the connections are reversed. 1. Keep wiring as short as possible.
Applicable models D-A73, A73H, A73C, C73, C73C, E73A, Z73, R73 D-97, 93A, A93, A93V D-A33, A34, A33A, A34A, A44, A44A D-A53, A54, B53, B54 2) However, when using a 2 color indication auto switch (DA79W, A59W, B59W), be aware that the switch will constantly remain ON if the connections are reversed.
Stroke Reading Rodless Cylinder with Brake ML2B Series RoHS 25, 32, 40 CEP1 How to Order CE1 CE2 ML2B 25 500 L Y7BW ML2B ML2B Basic type Bore size Number of auto switch 25 32 40 25 mm 32 mm 40 mm Nil S n 2 pcs. 1 pc. n pcs.
Nm N M1 M M3 W W2 W W4 ML2B25 10.0 1.2 3.0 200.0 58.0 65.0 100.0 ML2B32 20.0 2.4 6.0 300.0 80.0 96.0 150.0 ML2B40 40.0 4.8 12.0 500.0 106.0 140.0 250.0 ML2B25 ML2B32 ML2B40 J 0.43 0.68 1.21 18 ML2B/M1 ML2B/W1 ML2B/W1 0 0 0 Nm 0 0 0 N N 0 m/s m/s m/s ML2B/M2 ML2B/W2 ML2B/W2 N m N N m/s ML2B/M3 m/s m/s 20 ML2B/W3 ML2B/W3 10 Nm 5 3 2 1 N N m/s m/s m/s ML2B/W4 500 N 00 N
Applicable model: D-A73, A73H, A73C, C73, C73C, E73A, Z73 D-R73, R73C, 97, 93A, A93, A93V D-A33, A34, A33A, A34A, A44, A44A D-A53, A54, B53, B54 2) When using a 2-color indicator type auto switch (D-A79W, A59W and B59W), the auto switch will constantly remain ON if the connections are reversed.
M9PV M9P Solid state switch Reed switch 3-wire (PNP) [Y7PV] [Y7P] M9BV M9B 2-wire 12V [Y69B] [Y59B] M9NW Relay, PLC 24V Grommet Yes M9NWV 3-wire (NPN) [Y7NWV] [Y7NW] 5V, 12V IC circuit Diagnostic indication (2-color indication) M9PWV M9PW 3-wire (PNP) [Y7PWV] [Y7PW] M9BWV M9BW 2-wire 12V [Y7BWV] [Y7BW] 3-wire (NPN equivalent) A96V A96 Z76 5V IC circuit Yes A93V A90V A93 A90 Z73
Z73 Y59A Y7P Y59B Y7NW Y7PW Y7BW 3-wire (NPN) 2-wire Y69A Y7PV Y69B Y7NWV Y7PWV Y7BWV 100 V or less IC circuit 5 V, 12 V 3-wire (PNP) IC circuit 2-wire 12 V Relay, PLC 24 V Grommet 3-wire (NPN) 3-wire (PNP) 5 V, 12 V Diagnostic indication (2-color indication) 2-wire 12 V Lead wire length symbols: 0.5 m Nil (Example) Y59A 3 m L (Example) Y59AL 5 m Z (Example) Y59AZ Since there are
With no external leakage, the CY series can be used in many diverse environments. Magnetically coupled cylinders have a wide range of applications, and save mounting space. Loads and moments are possible through the use of integrated guides. A variety of guides can be used to achieve the necessary accuracy or allowable moment needed for your application. CY is available in 9 bore sizes,
With no external leakage, the CY series can be used in many diverse environments. Magnetically coupled cylinders have a wide range of applications, and save mounting space. Loads and moments are possible through the use of integrated guides. A variety of guides can be used to achieve the necessary accuracy or allowable moment needed for your application. CY is available in 9 bore sizes,
Piping: Standard, Bore Size: 40mm, Port Thread: (M5 Thread-6~15mm)(Rc-20~63mm), Stroke: 500mm, Auto Switch: M9P--Solid State , Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: L (3m), Number: S (1 pc.)