SMC Corporation of America
Elite Part Number Search
Search Results "CY3R40-300-Z73"

Standard Stroke DMaximum manufacturable stroke Bore size (mm) -X Standard stroke (mm) 20700 32 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500 800 40 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500 Data 1000 50 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 1000 63 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500

/s) 50 1200 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 C85 -XC3 Special port location 63 1200 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 -XC4 With heavy duty scraper 80 1400 C95 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 Heat resistant cylinder (110 C) -XC5 100 1500 25, 50, 75, 100, 125, 150, 175

CRJ 400 CRA1 Displacement (m) Displacement (m) CRQ2 MSQ 250 MSZ 350 CRQ2X MSQX MRQ 200 300 30 25 20 15 10 5 0 40 30 20 10 0 Load (N) Load (N) MSQXB30A MSQXB50A 350 300 300 250 Displacement (m) Displacement (m) 250 200 200 150 150 D100 100 100 80 60 40 20 0 50 40 30 20 10 0 Load (N) Load (N) 329 Series MSQX Construction o i w@3 r !

Applicable models D-A73, A73H, A73C, C73, C73C, E73A, Z73, R73 D-97, 93A, A93, A93V D-A33, A34, A33A, A34A, A44, A44A D-A53, A54, B53, B54 2) However, when using a 2 color indication auto switch (DA79W, A59W, B59W), be aware that the switch will constantly remain ON if the connections are reversed.

Sumitomo 3M Limited Manufacturer's part no. 1-1473562-4 1-1473562-4 1473562-4 1-1473562-4 1473562-4 1473562-4 1473562-4 1473562-4 1473562-4 1473562-4 1473562-4 1473562-4 2-1473562-4 2-1473562-4 2-1473562-4 D-A9 D-M9 D-Y D-Z73 D-Z76 D-Z80 Z/ISE1 Note 1) ZS-28-C ZS-28-C ZS-28-C ZS-28-C ZS-28-C-1 ZS-28-C-1 ZS-28-C-1 ZS-28-C-1 ZS-28-C-1 ZS-28-C-1 ZS-28-C-1 ZS-28-C-1 ZS-28-C-1 ZS-28-C-1 ZS-28-

125 L M9BW With auto switch CDS2 L 125 300 With auto switch (Built-in magnet) Made to Order For details, refer to the next page.

Clean Room Rodless Cylinder Series CYP 15, 32 How to Order MX CYP 15 Z73 200 MTS MY Number of auto switches Nil S n 2 pcs. 1 pc. n pcs. CY MG Bore size 15 32 15 mm 32 mm CX Auto switch Nil Without auto switch DFor the applicable auto switch model, refer to the table below.

Provides high linearity and high precision. 1 Series CYP How to Order CYP 15 Z73 200 Clean rodless cylinder Cylinder bore size Number of auto switches 15 32 15mm 32mm 2 pcs. 1 pc. n pcs. Nil S n Standard stroke Standard stroke (mm) 100, 150, 200, 250, 300 350, 400, 450, 500, 600, 700 Bore size (mm) Type of auto switch 15, 32 Nil Select auto switches from the table below.

Built-in magnet for auto-switches CV MVGQ Maximum Driving Speed of Cylinders 1000 1000 900 900 Cylinder speed (mm/s) Cylinder speed (mm/s) 800 800 Load factor: 10% Load factor: 50% 700 700 600 600 500 500 400 400 300 300 200 200 100 100 0 12 16 20 25 32 40 50 63 80 100 0 SYJ3000 VZ3000 VZ5000 VF3000 Bore size (mm) Series Variations Bore size (mm) Standard stroke (mm) Applicable valve series

Applicable model: D-A73, A73H, A73C, C73, C73C, E73A, Z73 D-R73, R73C, 97, 93A, A93, A93V D-A33, A34, A33A, A34A, A44, A44A D-A53, A54, B53, B54 2) When using a 2-color indicator type auto switch (D-A79W, A59W and B59W), the auto switch will constantly remain ON if the connections are reversed.

Applicable model: D-A73, A73H, A73C, C73, C73C, E73A, Z73 D-R73, R73C, 97, 93A, A93, A93V D-A33, A34, A33A, A34A, A44, A44A D-A53, A54, B53, B54 2) When using a 2-color indicator type auto switch (D-A79W, A59W and B59W), the auto switch will constantly remain ON if the connections are reversed.

seals 110C Heat resistant tarpaulin Double clevis pin and double knuckle pin Maximum ambient temperature for the rod boot itself. 25, 50, 75, 100, 125, 150, 200, 250, 300, 350, 400, 450, 500, 600 -XC27 50, 63 made of stainless steel -XC28 Compact flange made of SS400 25, 50, 75, 100, 125, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700 80, 100 -XC29 Double knuckle joint with spring pin

, 350 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350 50, 75, 100, 125, 150, 175, 200, 250, 300, 350 RLQ Manufacture of Intermediate Stroke MLU Spacer installation type Spacers are installed in the standard stroke cylinders. 20 to 32: Stroke can be modified by the 1 mm interval. 40 to 100: Stroke can be modified by the 5 mm interval.

, 350, 400, 450, 500 nut made of stainless steel 25, 50, 75, 100, 125, 150, 175, 200, 250, XC8 XC9 XC14 XC15 XC22 Adjustable stroke/Extension adjustment 1 50, 63 300, 350, 400, 450, 500, 600 2 Adjustable stroke/Retraction adjustment 25, 50, 75, 100, 125, 150, 175, 200, 250, Change of trunnion bracket mounting position 80, 100 300, 350, 400, 450, 500, 600, 700 Change of tie-rod length Types

, 350, 400, 450, 500 Replacement Parts: Seal Kits 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 50, 63 Bore size (mm) Contents Kit No. 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700 80, 100 40 50 63 80 100 CA2Y40-PS Rod seal 1 pc.

Straight type Stroke Air supply unit Note 1) 200 250 300 350 400 450 500 600 1000 200mm 250mm 300mm 350mm 400mm 450mm 500mm 600mm 1000mm Qty. None 1 set 2 sets Description Symbol Nil AS AW A unit (Air system 1) Note 1) Air supply unit, 1 set breakdown: Supply block (slide table side) 1pc. Supply ring (plate side) 2pcs. The maximum produceable stroke is 5000mm.

C J G5-S Standard Stroke CV Bore size (mm) Standard stroke (mm) Symbol Specifications 40 25, 50, 75, 100, 125, 150, 200, 250, 300, 350, 400, 450, 500 -XA Change of rod end shape MVGQ 50, 63 25, 50, 75, 100, 125, 150, 200, 250, 300, 350, 400, 450, 500, 600 -XC4 With heavy duty scraper 80, 100 25, 50, 75, 100, 125, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700 Piston rod and rod end nut

To use the system in a magnetic field that exceeds this value, use a magnetic material to shield the sensor unit. 63 50 50 40 40 YES 100 200 300 400 500 100 200 300 400 500 NO Does the mounted load exceed the load given in the diagram? Piston speed (mm/s) Horizontal mounting Piston speed (mm/s) Vertical mounting Selection O.K.

100 200 300 400 500 100 200 300 400 500 Piston speed (mm/s) Horizontal mounting Piston speed (mm/s) Vertical mounting Selection O.K. NO NO YES Is it possible for cable of stroke reading cylinder to be wired separately from the power line? Is there any influence of noise? YES NO YES NO Can the system be operated below 14.5 mT? Do not use it since it will result in a miscount.

To use the system in a magnetic field that exceeds this value, use a magnetic material to shield the sensor unit. 63 50 50 40 40 YES 100 200 300 400 500 100 200 300 400 500 NO Does the mounted load exceed the load given in the diagram? Piston speed (mm/s) Horizontal mounting Piston speed (mm/s) Vertical mounting Selection O.K.