C) Circulating fluid temperature (C) HEC012 Circulating fluid: Clear water Circulating fluid: FC-3283 50 70 90 110 130 150 F 50 70 90 110 130 150 F 3000 3000 Facility water: 68F (20C) Facility water: 50F (10C) 2500 2500 Facility water: 50F (10C) Cooling capacity (W) Cooling capacity (W) Facility water: 68F (20C) 2000 2000 Facility water: 95F (35C) 1500 1500 Facility water: 95F (35C) 1000
Pressure characteristics Flow characteristics Supply pressure: 0.7 MPa Set pressure: 0.2 MPa Relief flow characteristics Supply pressure: 0.7 MPa 1.0 0.6 0.8 Output deviation factor (%F.S.) 0.7 0.5 0.5 0.6 Set pressure (MPa) Set pressure (MPa) 0.4 Set point 0.5 0.3 0.0 0.4 0.3 0.2 0.2 0.5 0.1 0.1 1.0 0 500 1000 1500 2000 0.0 0.0 0.8 0.2 0.4 0.6 0 500 1000 2000 1500 Flow rate (L/min (ANR))
1200 1350 1500 0 150 300 450 600 750 900 1050 1200 1350 Distance [mm] Distance [mm] 5) Supply pressure: 0.4 MPa Flow rate consumption: 316 L/min (ANR) 6) Supply pressure: 0.5 MPa Flow rate consumption: 390 L/min (ANR) 200 200 2 s 150 150 1.5 s 100 100 50 50 0.5 s 1 s 1.5 s 0.5 s 1 s 50 50 100 100 150 150 200 200 1500 0 150 300 450 600 750 900 1050 1200 1350 1500 0 150 300 450 600 750 900
Please contact SMC. 3) 14 to 194F (10 to 90C) for Vespel seat. 4) Tested with Helium gas inlet pressure 1500 psig (10.5 MPa). 5) Tested with Helium gas inlet pressure 1000 psig (7 MPa). 6) On panel mount option, bonnet port is not threaded. 7) Mass, including individual boxed weight, may vary depending on connections or options.
20 ML1C 700 1500 25 1000 1500 32 REA 1000 1500 40 *It is possible in each size to manufacture the cylinder with 1500 stroke maximum.
With no external leakage, the CY series can be used in many diverse environments. Magnetically coupled cylinders have a wide range of applications, and save mounting space. Loads and moments are possible through the use of integrated guides. A variety of guides can be used to achieve the necessary accuracy or allowable moment needed for your application. CY is available in 9 bore sizes,
With no external leakage, the CY series can be used in many diverse environments. Magnetically coupled cylinders have a wide range of applications, and save mounting space. Loads and moments are possible through the use of integrated guides. A variety of guides can be used to achieve the necessary accuracy or allowable moment needed for your application. CY is available in 9 bore sizes,
With no external leakage, the CY series can be used in many diverse environments. Magnetically coupled cylinders have a wide range of applications, and save mounting space. Loads and moments are possible through the use of integrated guides. A variety of guides can be used to achieve the necessary accuracy or allowable moment needed for your application. CY is available in 9 bore sizes,
Bore Size: 20mm, Port Type: TN (NPT), Stroke: 150mm
Bore Size: 20mm, Port Type: TN (NPT), Stroke: 400mm
Bore Size: 20mm, Port Type: TN (NPT), Stroke: 450mm
Bore Size: 20mm, Port Type: TN (NPT), Stroke: 300mm
Bore Size: 20mm, Port Type: TN (NPT), Stroke: 800mm
Bore Size: 20mm, Port Type: TN (NPT), Stroke: 200mm
Bore Size: 20mm, Port Type: TN (NPT), Stroke: 350mm
Bore Size: 20mm, Port Type: TN (NPT), Stroke: 600mm
Bore Size: 20mm, Port Type: TN (NPT), Stroke: 500mm
Bore Size: 20mm, Port Type: TN (NPT), Stroke: 700mm
Bore Size: 20mm, Port Type: TN (NPT), Stroke: 250mm
Piping: Standard, Bore Size: 20mm, Port Thread: TN (NPT), Stroke: 600mm, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 4 pcs.