Cylinder: w/Auto Switch/Plate Mount, Model: Non-lube, Bore Size: 3/8 Inch, Stroke: 4 Inch, Cushion: Two Adjuster Bolts, Auto Switch: A73--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Vertical, 0.5M, Number: -
Cylinder: w/Auto Switch/Plate Mount, Model: Non-lube, Bore Size: 1 Inch, Stroke: 4 Inch, Cushion: Two Adjuster Bolts, Auto Switch: A73--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Vertical, 0.5M, Number: -
Bore Size: 15mm, Port Thread: Rc, Magnetic Holding Force: Large Holding Force, Stroke: 400mm, Adjuster: Adjuster Bolt, Auto Switch: A73--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Vertical, Lead Wire or Prewired Connector: -, Number: -
Bore Size: 25mm, Port Thread: Rc, Magnetic Holding Force: Large Holding Force, Stroke: 400mm, Adjuster: Adjuster Bolt, Auto Switch: A73--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Vertical, Lead Wire or Prewired Connector: -, Number: -
Bore Size: 40mm, Port Thread: Rc, Magnetic Holding Force: Large Holding Force, Stroke: 400mm, Adjuster: Adjuster Bolt, Auto Switch: A73--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Vertical, Lead Wire or Prewired Connector: -, Number: -
Bore Size: 32mm, Port Thread: Rc, Magnetic Holding Force: Large Holding Force, Stroke: 400mm, Adjuster: Adjuster Bolt, Auto Switch: A73--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Vertical, Lead Wire or Prewired Connector: -, Number: -
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, CY1H/CY1L GUIDED CYLINDER, GE, 15MM CY1H/CY1L DBL-ACT A/S, 3.62439 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, RODLESS, ACTUATOR, CY1H/CY1L GUIDED CYLINDER, GE, 15MM CY1H/CY1L DBL-ACT A/S, 2.47799 lb, Bore size (mm)ModelAllowable load mass (Wv)(kg)Maximum operating pressure (Pv)(MPa)15CY1L15L4.10.40
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
With no external leakage, the CY series can be used in many diverse environments. Magnetically coupled cylinders have a wide range of applications, and save mounting space. Loads and moments are possible through the use of integrated guides. A variety of guides can be used to achieve the necessary accuracy or allowable moment needed for your application. CY is available in 9 bore sizes,
With no external leakage, the CY series can be used in many diverse environments. Magnetically coupled cylinders have a wide range of applications, and save mounting space. Loads and moments are possible through the use of integrated guides. A variety of guides can be used to achieve the necessary accuracy or allowable moment needed for your application. CY is available in 9 bore sizes,
Auto switch shown above is D-A73 type and D-A80 type. For the auto switch mounting position and its mounting height, refer to page 7-6-83.
Bore Size: 15mm, Port Thread: Rc (or M Thread for 6 to 15 Bore), Magnetic Holding Force: L (Small Holding Force), Stroke: 100mm, Adjuster: Adjuster Bolt, Auto Switch: J79C--Solid State, Gen. Purpose, 2 Wire, Connector, Vertical, Lead Wire or Prewired Connector: L (3m)
Bore Size: 15mm, Port Thread: Rc (or M Thread for 6 to 15 Bore), Magnetic Holding Force: L (Small Holding Force), Stroke: 150mm, Adjuster: B (Shock Absorbers (2 pcs)), Auto Switch: A73--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Vertical, Lead Wire or Prewired Connector: L (3m)
Bore Size: 15mm, Port Thread: Rc (or M Thread for 6 to 15 Bore), Magnetic Holding Force: L (Small Holding Force), Stroke: 500mm, Adjuster: Adjuster Bolt, Auto Switch: F7PW--Solid State, 2-color Indication, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: L (3m)
Bore Size: 15mm, Port Thread: Rc (or M Thread for 6 to 15 Bore), Magnetic Holding Force: L (Small Holding Force), Stroke: 50mm, Adjuster: Adjuster Bolt, Auto Switch: F7BA--Solid State, Water Resist., 2 Wire, Lead Wire, Horizontal, Lead Wire or Prewired Connector: L (3m)
Bore Size: 15mm, Port Thread: Rc (or M Thread for 6 to 15 Bore), Magnetic Holding Force: L (Small Holding Force), Stroke: 500mm, Adjuster: B (Shock Absorbers (2 pcs)), Auto Switch: A73H--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Horizontal, Lead Wire or Prewired Connector: L (3m)
Bore Size: 15mm, Port Thread: Rc (or M Thread for 6 to 15 Bore), Magnetic Holding Force: L (Small Holding Force), Stroke: 600mm, Adjuster: B (Shock Absorbers (2 pcs)), Auto Switch: F79W--Solid State, 2-color Indication, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: L (3m)
Bore Size: 15mm, Port Thread: Rc (or M Thread for 6 to 15 Bore), Magnetic Holding Force: L (Small Holding Force), Stroke: 700mm, Adjuster: B (Shock Absorbers (2 pcs)), Auto Switch: F79W--Solid State, 2-color Indication, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: Z (5m)
Bore Size: 15mm, Port Thread: Rc (or M Thread for 6 to 15 Bore), Magnetic Holding Force: L (Small Holding Force), Stroke: 50mm, Adjuster: Adjuster Bolt, Auto Switch: F7BV--Solid State, Gen. Purpose, 2 Wire, Lead Wire, Vertical, Lead Wire or Prewired Connector: L (3m)