Minimum Stroke for Auto Switch Mounting (mm) 12 16 20 25 32 40 50 63 80 100 Auto switch model No. of auto switches mounted 1 pc. 10 5 D-A9 2 pcs. 15 10 D-A9V D-M9V 1 pc. 5 2 pcs. 10 1 pc. 15 10 5 D-M9 2 pcs. 15 10 1 pc. 15 10 D-M9W 2 pcs. 15 10 1 pc. 10 D-M9WV 2 pcs. 10 D-Z7 D-Z80 1 pc. 10 5 2 pcs. 15 10 D-Y59 D-Y7P 1 pc. 5 10 2 pcs. 15 10 D-Y69 D-Y7PV 1 pc. 5 2 pcs. 5 D-Y7W D-Y7WV 1 pc.
M2 M3 m2 m3 16 20 25 32 40 50 63 16 20 25 32 40 50 63 6.0 3.0 1.0 18 7 2.1 10 5.2 1.7 26 10.4 3 15 9.0 2.4 38 15 4.5 MY1MW 30 15 5.0 57 23 6.6 59 24 8.0 84 33 10 115 38 15 120 48 14 140 60 19 180 72 21 6.0 3.0 2.0 18 7 2.1 10 5.0 3.0 25 10 3 15 8.5 5.0 35 14 4.2 30 14 10 49 21 6 MY1CW MY1B 60 23 20 68 30 8.2 115 35 35 93 42 11.5 MY1H 150 50 50 130 60 16 The above values are the maximum allowable
Work weight: 0.05kg Example 25 Pressure 0.6MPa 20 0.5 0.4 Holding force (N) 15 13 0.3 10 0.2 5 0.1 Ex.)
CY MG Bore size 15 32 15 mm 32 mm CX Auto switch Nil Without auto switch DFor the applicable auto switch model, refer to the table below.
Allowable load mass mv (kg) Maximum operating pressure Pv (MPa) Cushion Stroke Model Stroke (mm) 25 30 1 5 0.3 Model CYP15 CYP32 CYP15 CYP32 8-17-6 6 Clean Room Rodless Cylinder Series CYP 15, 32 How to Order MX CYP 15 Z73 200 MTS MY Number of auto switches Nil S n 2 pcs. 1 pc. n pcs.
Closed E 15 15 70 Open F 24 24 4-M10 X 1.5 through (Thread for mounting attachment) B C D E F G H 110 158 202 J 202 282 366 Model MHL2-32D MHL2-32D1 MHL2-32D2 56 104 148 272 370 454 86 134 178 220 318 402 150 198 242 60 108 152 Note 1) J dimension is at fully closed.
20 10 5 10 15 20 1 pc. 10 10 20 25 15 10 10 15 20 2 pcs.
Air Cylinder Speed controller Solenoid valve Regulator Air source Air filter Fig. 15 Basic Circuit 32 5. Construction A In the case of 125 Fig 16. Standard product: Double acting/single rod Table 12 Parts list No.
Example) In case an MGF63-15 specification is required, a spacer of 15mm is installed in the MGF63-30. Therefore, the total length is same as that of 30mm stroke. MGF 40 MGF 63 30, 50, 75, 100 MGF100 Minimum Strokes for Mounting Auto Switches (mm) Switch type D-Z7, D-Z8 D-Y5, D-Y6, D-Y7 Number of pcs. 10 5 1 pc. 15 10 2 pcs.
Provides high linearity and high precision. 1 Series CYP How to Order CYP 15 Z73 200 Clean rodless cylinder Cylinder bore size Number of auto switches 15 32 15mm 32mm 2 pcs. 1 pc. n pcs. Nil S n Standard stroke Standard stroke (mm) 100, 150, 200, 250, 300 350, 400, 450, 500, 600, 700 Bore size (mm) Type of auto switch 15, 32 Nil Select auto switches from the table below.
11 32 7 81 18 70 3/8 27 52 20 40 70 9 110 108 178 M18 x 1.5 15 59 35 14 63 17 31 Up to 1000 58 35 11 32 101 7 18 85 3/8 27 64 20 40 86 130 105 116 189 M10 x 1.25 M18 x 1.5 11.5 49 Actuator / Common Precautions 1 Be sure to read before handling.
39 45.5 55.5 103 121.5 145 M10 M12 M14 162 202 240 16.5 14.5 18 13.5 15.5 19 16.5 19 23 78 91.5 111.5 15 15 20 12 18 25 16 22 25 49 56.5 66 M6 X 1.0 M8 X 1.25 M8 X 1.25 22 26 32 58 54 62 39 46 56 M10 X 1.5 M12 X 1.75 M14 X 2.0 8.6 10.6 12.5 25, 50, 75, 100, 125, 150, 175, 200 (mm) Bore size (mm) OB OL P PA PB PW Q RA RB RC S SA SB T U VA VB WA WB 50, 75, 100st Larger than 100st 25st 50,
Design the machinery to avoid such dangers. 15 - 2-8. Pneumatic circuit W a r n i n g Use the pneumatic circuit which applies balance pressure to the both sides of the piston when locking.
Adjustment and Operation P.15 3. How to use P.16 3-1. Usage P.16 3-2. Lock release mechanism P.17 3-3. Auto switch P.19 3-4. Wiring method and examples of auto switches P.31 4. Maintenance P.32 4-1. Consumable parts P.32 4-1-1. Seal kit P.32 4-1-2. Storage of seals P.32 4-2. Lock unit replacement P.33 4-3. Checks P.34 4-3-1. Inspection points P.34 4-3-2. Inspection interval P.34 4-4.
Note 1) To protect auto switches, ensure that main body of an auto switch should be embedded into auto switch mounting groove with a depth of 15 mm or more. Note 2) Set the tightening torque of a hexagon socket head set screw (M4) to be 1 to 1.2 Nm.
Clean Room Rodless Cylinder Series CYP 15, 32 How to Order MX CYP 15 Z73 200 MTS MY Number of auto switches Nil S n 2 pcs. 1 pc. n pcs. CY MG Bore size 15 32 15 mm 32 mm CX Auto switch Nil Without auto switch DFor the applicable auto switch model, refer to the table below.
Example) In case an MGF63-15 specification is required, a spacer of 15mm is installed in the MGF63-30. Therefore, the total length is same as that of 30mm stroke. MGF 40 MGF 63 30, 50, 75, 100 MGF100 Minimum Strokes for Mounting Auto Switches (mm) Switch type D-Z7, D-Z8 D-Y5, D-Y6, D-Y7 Number of pcs. 10 5 1 pc. 15 10 2 pcs.
Bore size (mm) Bore size (mm) DL DM HR LL MO DB Over 25 to 75st 98 Over 75 to 175st 118 Over 25 to 75st 13.5 Over 75 to 175st 33.5 Over 175st 25st or less 25st or less Over 175st 22 22 9.5 21 15 15 84.5 140 16 0 55.5 32 32 26 23 11.5 25.5 21 19 91 98 118 140 16 0 7 27 49 40 40 24 23 13 27 21 19 50 97 114 134 161 20 0 17 37 64 50 25 25.5 11 25 21 19 63 102 114 134 161 20 0 12 32 59 63
External gripping force Internal gripping force MHS2-16D MHS2-16D 30 Pressure 0.6MPa Pressure 0.6MPa 30 0.5MPa 0.5MPa Gripping force N Gripping force N 20 20 0.4MPa 0.4MPa 0.3MPa 0.3MPa 10 10 0.2MPa 0.2MPa F 0 0 15 20 15 5 5 10 10 20 25 25 30 30 F Gripping point L mm Gripping point L mm MHS2-20D MHS2-20D 60 60 Pressure 0.6MPa Pressure 0.6MPa Gripping force N External gripping Gripping force
Series RSH 20, 32, 50, 63, 80 How to Order RSH 20 15 D L Z73 Heavy Duty Stopper Cylinder Bore size Number of auto switches 20mm 32mm 50mm 63mm 80mm 20 32 50 63 80 S 2 1 Auto switch Stroke Without auto switch (Cylinder built-in magnet) 15mm 20mm 30mm 40mm 20 32 50/63 80 * Refer to the table below for auto switch model nos.