SMC Corporation of America
Elite Part Number Search
Search Results "CXSJL10-10-M9BA"

(mm) 40 50 63 80 CA2-B04 CA2-B05 CA2-B06 CA2-B08 CA2-B10 +0.058 0 57 35 11 65 15 85 10 9 17 8 40 52 60 165 10 +0.070 0 57 35 11 65 18 85 10 9 17 8 40 52 70 183 12 +0.070 0 67 40 13.5 80 25 105 12.5 11 22 10 50 66 85 196 16 +0.084 0 93 60 16.5 100 31.5 130 15 13.5 24 12 65 90 102 235 20 100 +0.084 0 93 60 16.5 100 35.5 130 15 13.5 24 12 65 90 116 256 25 10 Series CA2 Dimensions of Accessories

85 15 50 16 12 12 10 51 8 M8 x 1.25 6 Up to 600 35 32 70 27 108 1/4 1/8 52 20 40 10 95 17 56 20 13 15 12 58 11 M8 x 1.25 7 Up to 600 35 32 86 27 115 1/4 1/4 64 20 40 10 102 17 65 20 18 12 15 58 11 M10 x 1.25 7 Up to 750 40 37 102 32 139 1/4 1/4 78 25 52 14 123 21 79.5 20 23 18 17 71 13 M12 x 1.75 10 Up to 750 40 37 116 41 160 1/4 1/4 92 30 52 14 144 21 93.5 22 25 20 19 72 16 M12 x 1.75 10

11 depth 6.5 63 1/4 19.5 10 40 65 55 10 22.4 19 M16 x 2 20 7 52 9 14 depth 8.6 71 1/4 20.5 10 50 71 60 11 28 24 M20 x 2.5 24 8 58 11 17.5 depth 10.8 81 1/4 22 10 63 80 67 13 35.5 30 M27 x 3 33 9 69 13 20 depth 13 97 1/4 25.5 10 80 95 78 17 45 41 M30 x 3.5 36 14 86 15 23 depth 15.2 117 3/8 30 15 100 122 96 26 56 50 M39 x 4 45 21 106 17 26 depth 17.5 142 3/8 36 15 Note 1) Body dimensions are

Applicable bore size A D L MM N R W Flat type Round type CJ-CF010 CJ-CR010 10 8 10 13 M4 x 0.7 6 10 8 Part no.

Replacement parts (With external shock absorber type) Description Size 10 20 30 50 P891010-10 P891020-10 P891030-10 P891040-10 Seal kit No. Description Qty. No. Description Qty. No. Description Qty. No. Description Qty.

mm/s Symbol Rubber bumper Allowable kinetic energy 10 0.035 J 16 0.090 J Minimum Operating Pressure Unit: MPa Bore size (mm) 10 16 Minimum operating pressure 0.03 Standard Strokes Made to Order (For details, refer to pages 1069 to 1262.)

Cylinder Specifications 10 3-2. Sensor Specifications 10 3-3. Allowable Kinetic Energy 11 3-3-1. Allowable Kinetic Energy 11 3-3-2. Mass of Cylinder Movable Parts11 3-3-3. Load mass and Piston Speed 11 4. Wiring 4-1. Connector Wiring Table 12 4-2. Wiring for Counter 12 4-3. Noise countermeasures 12 5. Structure and Measuring Principle 5-1. Structure 13 5-2.

A-phase pulse B-phase pulse 11 12 11 10 10 Count multiplier In rod extending direction, A-phase turns on first, then B-phase turns on with the delay of In rod retracting direction, B-phase turns on first, then A-phase turns on with the delay of approximately 90 phase difference. approximately 90 phase difference. Counter performs addition in and does subtraction in .

Magnet: D (Built-in), Mounting: B [Through Hole (Standard)], Bore Size: Ø32 mm, Port Thread: M Thread [ø12-ø25]; Rc [ø32-ø100], Stroke: 10 mm, Auto Switch: M9BA--Solid State, Water Resist., 2 Wire, Horizontal

Magnet: Built-in, Mounting: B [Through Hole (Standard)], Bore Size: Ø32 mm, Port Thread: M Thread [ø12-ø25]; Rc [ø32-ø100], Stroke: 10 mm, Auto Switch: M9BA--Solid State, Water Resist., 2 Wire, Horizontal, Lead Wire or Prewired Connector: -, Number: -

AC Lead wire length (m) Load voltage DC Auto switch model Special function Electrical entry Indicator light Wiring (Output) Pre-wired connector Applicable load Type In-line Perpendicular 0.5 (Nil) 1 (M) 3 (L) 5 (Z) M9NV M9PV M9BV M9NWV M9PWV M9BWV M9NAV M9PAV M9BAV M9N M9P M9B M9NW M9PW M9BW M9NA M9PA M9BA 5 V, 12 V 3-wire (NPN) 3-wire (PNP) IC circuit Solid state switch 12 V 2-wire 3-wire

Model CYP15 CYP32 Series Throttle valve 10-AS2200-01-X214 Elbow type 10-AS1200-M5-X216 Metal body piping type 10-AS2000-01-X209 In-line type 10-AS1000-M5-X214 10-AS2201F-01-04-X214 10-AS1201F-M5-04-X214 Elbow type (throttle valve) 10-AS2201F-01-06-X214 10-AS1201F-M5-06-X214 10-AS2201F-01-06-X214 Operation 10-AS2301F-01-04-X214 10-AS1301F-M5-04-X214 Resin body with One-touch fitting Caution

10 12 12 16 16 26 30 36 42 48 54 64 78 19 19 30 30 38 38 60 60 5 5 6 6 10 10 12 12 51 58 68 82 100 108 139 153 8 8 10 10 12 12 16 16 18 22 24 30 34 40 46 58 7 7 9 9 9 9 10 10 13 15 18 21 24 27 32 39 6 8 10 13 16 16 20 20 13 15 18 21 24 27 32 39 29 33 37 37.5 37.5 44 44 49 8 10 12 16 20 20 25 25 7.5 8 8.5 9 9 10 11 13.5 M4 M4 M5 M5 M6 M6 M8 M10 90 42 46 53 53.5 59.5 66 72 77 6 8 10 12 16

MY1B10G Stroke 10 10 7.3 7.8 2 x M5 x 0.8 (Hexagon socket head plug) 2 x 2 x 3.4 through-hole Bottom side M4 x 0.7 depth 7 4 x M3 x 0.5 depth 5 30 50 5.9 5.9 25 26 22 28 17 100 + Stroke 5 Floating bracket mounting thread (2 x M3 x 0.5 thread depth 5) 2 x 5 counterbore depth 2 25 24 3.5 1 2 x M5 x 0.8 (Port) 1 3 3 2.2 6.8 1.7 7.3 SMC SMC 27 20.2 19.5 10 10 10 10 15 15 8.5 12 12 8.5 55 110

14 4 4 6 10 14 4 4 6 10 14 6 10 16 20 25 6 10 16 20 25 6 10 16 20 25 Double acting Single acting type, Normally closed Normally closed Normally open MHZ MHF Single acting 3.7 12 31 56 83 MHL Refer to pages 436 to 440 for the specifications with auto switch.

2 (Different surfaces) 10 n 10 + 30 (n 2) D-A9l 2 (Same surface) 50 1, 2 (Different surfaces) 10 n 10 + 40 (n 2) D-A9lV 2 (Same surface) 40 1, 2 (Different surfaces) 10 n 10 + 30 (n 2) * n = 3, 4, 5 * The D-M9lV/M9lWV/M9lAV/A9lV are mountable on 32 to 63.

4.5 7 142 144 32 64 7 50 79 16 10 130 45 26 26 10 12 9.5 142 65 55 36 36 11 4.5 10 161 163 36 72 9 55 90 20 10 145 52 28 28 12 15 12 160 75 68 45 45 12 5.5 10 170 175 45 90 9 70 110 25 12 155 60 32 32 12 15 12 170 80 80 50 50 12 5.5 10 185 190 50 100 9 80 120 25 12 170 70 40 40 16 20 16 190 90 100 63 63 14 6.5 12 210 215 63 126 12 100 153 30 16 190 90 50 50 16 20 16 210 110 120 75 71 16

14 14 14 11.5 12 13.5 14.5 12 12.5 14.5 15 10 10 11.5 11.5 12 The auto switches listed below cannot be mounted on 63.