Size, Body, Valve Type: 30D (Size: 3; Body Mat'l: Aluminum; Port Size: 3/8; Orifice Dia: 5, N.C.), Voltage and Electrical Entry: C (110VAC; Grommet w/Surge Voltage Suppressor), Other Voltages and Electrical Options: None, Other Options: E (Oil-free, NPT Thread)
Size, Body, Valve Type: 30D (Size: 3; Body Mat'l: Aluminum; Port Size: 3/8; Orifice Dia: 5, N.C.), Voltage and Electrical Entry: Z (Other Voltages and Electrical Options), Other Voltages and Electrical Options: 2K (24VDC; Conduit Terminal w/Surge Voltage Suppressor & Light), Other Options: B (NPT Thread), Bracket Interchangeable with Old Type: XB
Size, Body, Valve Type: 30D (Size: 3; Body Mat'l: Aluminum; Port Size: 3/8; Orifice Dia: 5, N.C.), Voltage and Electrical Entry: Z (Other Voltages and Electrical Options), Other Voltages and Electrical Options: 2A (24VDC; DIN Terminal w/Surge Voltage Suppressor & Light), Other Options: None, Bracket Interchangeable with Old Type: XB
Size, Body, Valve Type: 30D (Size: 3; Body Mat'l: Aluminum; Port Size: 3/8; Orifice Dia: 5, N.C.), Voltage and Electrical Entry: Z (Other Voltages and Electrical Options), Other Voltages and Electrical Options: 2A (24VDC; DIN Terminal w/Surge Voltage Suppressor & Light), Other Options: A (G Thread)
Size, Body, Valve Type: 30D (Size: 3; Body Mat'l: Aluminum; Port Size: 3/8; Orifice Dia: 5, N.C.), Voltage and Electrical Entry: Z (Other Voltages and Electrical Options), Other Voltages and Electrical Options: 2A (24VDC; DIN Terminal w/Surge Voltage Suppressor & Light), Other Options: Z (Oil-free, Rc Thread)
) O P T I O N S T Y P E XB6 High Temperature XB7 ...Low Temperature XB9 Low Friction XC6 Stainless Steel Rod N O O F S W I T C H E S Standard Cylinder K Non Rotating Rod W .
) O P T I O N S T Y P E XB6 High Temperature XB7 ...Low Temperature XB9 Low Friction XC6 Stainless Steel Rod N O O F S W I T C H E S Standard Cylinder K Non Rotating Rod W .
-XB6 Heat resistant cylinder (10 to 150C)*2 -XB7 Cold resistant cylinder (40 to 70C)*3 * Mounting bracket, double knuckle joint, and auto switch are shipped together with the product.
Contents 150 NC1A150-PS-XB6 150 NC1A150-PS-XB7 200 NC1A200-PS-XB6 200 NC1A200-PS-XB7 250 NC1A250-PS-XB6 250 NC1A250-PS-XB7 325 NC1A325-PS-XB6 325 NC1A325-PS-XB7 400 NC1A400-PS-XB6 400 NC1A400-PS-XB7 Rod Option: Double, Special Option: High Temp. Rod Option: Double, Special Option: Low Temp. Bore Size (mm) Kit no. Contents Bore Size (mm) Kit no.
Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.07~1.0, Support bracket: Threaded, Port thread type: M5, Body Options: Rod End Female Thread, Auto Switches
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.07~1.0, Support bracket: Threaded, Port thread type: M5, Body Options: Rod End Female Thread, Auto Switches
Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.07~1.0, Support bracket: Through hole, Port thread type: M5, Body Options: Rod End Female Thread, Auto Switches
[Or None in the Case of No Switch], Option: XB7 [Cold Resistant (-40 to 70°C)]
[Or None in the Case of No Switch], Option: XB7 [Cold Resistant (-40 to 70°C)]
Mounting: B (Through-hole, Standard), Bore Size: 40mm, Port Thread: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 30mm, Body Option: Standard, Rod End Female Thread, Auto Switch Groove: None (for 12-25 Bore w/o Magnet), Temperature Resistant Option: XB7 [Cold Resistant (-40 to 70°C)]
(Or None in the Case of No Switch), Temperature Resistant: XB7 [Cold Resistant (-40 to 70°C)]
(Or None in the Case of No Switch), Temperature Resistant: XB7 [Cold Resistant (-40 to 70°C)]
(Or None in the Case of No Switch), Temperature Resistant: XB7 [Cold Resistant (-40 to 70°C)]
Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.07~1.0, Support bracket: Threaded, Port thread type: M5, Body Options: Rod End Female Thread, Auto Switches
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.07~1.0, Support bracket: Threaded, Port thread type: M5, Body Options: Rod End Female Thread, Auto Switches