SMC Corporation of America
Elite Part Number Search
Search Results "CDQSD12-30DCM-A90"

Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 20, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: High rigidity / high precision high class guide, Environment, Applications: Standard, Cushion: None, Operating Pressure(MPa): 0.07 to 1.0, Specification: Built-in magnet, Auto Switches

Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: High rigidity / high precision high class guide, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.07 to 1.0, Specification: Built-in magnet

Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: High rigidity / high precision high class guide, Environment, Applications: Standard, Cushion: None, Operating Pressure(MPa): 0.07 to 1.0, Specification: Built-in magnet, Auto Switches

Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: High rigidity / high precision high class guide, Environment, Applications: Standard, Cushion: None, Operating Pressure(MPa): 0.07 to 1.0, Specification: Built-in magnet, Auto Switches

Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: High rigidity / high precision high class guide, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.07 to 1.0, Specification: Built-in magnet

Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: High rigidity / high precision high class guide, Environment, Applications: Standard, Cushion: None, Operating Pressure(MPa): 0.07 to 1.0, Specification: Built-in magnet, Auto Switches

Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 35, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: High rigidity / high precision high class guide, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.07 to 1.0, Specification: Built-in magnet

Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 35, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: High rigidity / high precision high class guide, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.07 to 1.0, Specification: Built-in magnet

Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 40, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: High rigidity / high precision high class guide, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.07 to 1.0, Specification: Built-in magnet

Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: High rigidity / high precision high class guide, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.07 to 1.0, Specification: Built-in magnet

Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: High rigidity / high precision high class guide, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.07 to 1.0, Specification: Built-in magnet

Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 10, Cylinder Operation Method: [Single Action Retraction] Single Acting, Spring Extend, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: High rigidity / high precision high class guide, Environment, Applications: Standard, Cushion: None, Operating Pressure(MPa): 0.25 to 1.0, Specification

(V), D-A93(V), D-A96(V) Specifications D-A96 D-A90 In-line D-A90V D-A93 In-line D-A93V In-line D-A96V Auto switch part no.

MXU MK2 6, 10, 16 32, 40, 50, 63 MXW RSQ 8, 12, 16, 20, 25 12, 32, 40, 50 MXF CEP 8, 12, 16, 20 12, 20 MXS/MXQ CY1R 6, 8, 12, 16, 20, 25 6, 10, 15, 20 *Not applicable for CDQP2 Specifications PLC: Programmable Logic Controller D-A90 (Without indicator light) Internal Circuit ( ): If not applicable for IEC Standard D-A90 Auto swich modle number D-A90 Application IC circuit/Relay/PLC Contact

A96 5 V IC circuit Yes A93 A90 A54 A64 A33C A34C A44C A59W IC circuit B54 B64 A33 A34 A44 B59W 100 V Grommet 100 V or less No Yes No Relay, PLC 100 V, 200 V 12 V 200 V or less 2-wire 24 V Terminal conduit PLC 100 V, 200 V Yes DIN terminal Grommet Relay, PLC Diagnostic indication (2-color indication) Lead wire length symbols: 0.5m Nil (Example)M9NW 1m M (Example)M9NWM 3m L (Example

(V), D-A93(V), D-A96(V) Auto Switch Specifications D-A96 D-A90 D-A90V D-A93 D-A93V In-line D-A96V Auto switch part no.

M9NW M9PW M9BW P3DWA P4DW 3-wire (NPN) 3-wire (PNP) 2-wire 3-wire (NPN) 3-wire (PNP) 2-wire IC circuit 5 V,12 V 12 V Solid state auto switch Relay, PLC 24 V Yes Grommet Diagnostic indication (2-color indicator) IC circuit 5 V,12 V 12 V Magnetic field resistant (2-color indicator) 2-wire (Non-polar) 3-wire (NPN equivalent) 5 V IC circuit A96 Reed auto switch Yes 12 V Grommet A93 A90

indicator) 2-wire 12 V M9BWV M9BW K59W Grommet 3-wire (NPN) 5 V, 12 V M9NAV*1 M9NA*1 IC circuit 3-wire (PNP) M9PAV*1 M9PA*1 Water resistant (2-color indicator) 2-wire 12 V M9BAV*1 M9BA*1 G5BA*1 With diagnostic output (2-color indicator) 4-wire (NPN) 5 V, 12 V H7NF G59F IC circuit Yes 3-wire (Equiv. to NPN) 5 V A96V A96 IC circuit Reed auto switch 100 V A93V*2 A93 No 100 V or less A90V A90

24V 100V -0.076 ~ -0.04 9.53 0.74 25 1.66 PS-03 8.94 25 20.2 24V/48V/100V AC/DC D-A80 D-A80H 2 Wire No 100V -0.076 ~ -0.04 9.53 0.74 41 1.66 PS-04 8.94 32, 40 36.2 Reed Switch D-A73C Yes 24V -0.076 ~ -0.05 12.7 1 50 1.9 PS-05 11.89 50, 63 44.2 D-A80C No 24V 24V -0.117 ~ -0.065 19.05 1.17 64 2.73 PS-08 17.89 80 56.2 D-A79W Yes 24V -0.117 ~ -0.065 22.23 1.17 72 2.73 PS-10 20.85 100 64.2 D-A90

A90 A90V No Reed switch Solid state switch 2 wire 24V A93 A93V Grommet 100V 12V Yes 3 wire (NPN equiv.)