m Dd9 L (Drill through) 3 x 18 l 4 x 25 l 4 x 35 l 4 x 36 l 0.040 0.076 CD-M03 CD-M05 CD-M08 CDP-7A 10 14 22 25 20, 25 32, 40 50, 63 80 3 4 4 4 4 4.5 5 5 36 51 72 78 44 60 82 88 0.050 0.093 0.065 0.117 0.065 0.117 l m L Note) When using cotter pins, flat washers are used together.
A F F L = 200 mm F L = 200 mm A L L MX L L = 200 mm MTS A MXW8/12/16 MXW8/12/16 MXW8/12/16 MY 0.03 0.03 0.10 CY MXW12 MXW8 MXW16 Table displacement amount (mm) Table displacement amount (mm) Table displacement amount (mm) MXW12 MXW8 MXW16 0.08 MG MXW12 MXW8 MXW16 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local
Lead wire length symbols: 0.5 m Nil 3 m L 5 m Z Solid state switches marked "" are produced upon receipt of order.
L Rubber stopper screw Switch rail Mounting tap L Stud fastening: After a temporary tightening, tighten an additional 1/4 turn. Metal stopper screw L Shock absorber 8-9-16
YES Calculation of resistance force f n 1 (L/GP) 2 (Provided that L > GP) Calculation of theoretical output F L W Refer to Theoretical Output 1 on page 8-27-3.
(Example) A93 3m . L (Example) A93L 5m . Z (Example) F9NWZ Solid state switches marked with a " " are produced upon receipt of order.
MX MTS MY Centralized piping on right CY MG CX R R L DL -X R L Slide table actuation direction 20Centralized piping on left Data R L L R R L Slide table actuation direction 4. Never disassemble the magnetic component parts (external slider, internal slider) of the actuator (cylinder). If will cause decline of the holding force, etc. 2.
CY1F10 to 25-AAL CY1F10 to 25-AAR L EA approx.
CBQ2 Standard A93 S B 50 D C CDBQ2 With Auto Switch 32 H L Number of auto switches With auto switch (built-in magnet) 2 pcs. 1 pc.
Nil (Example) A93 3m .
150 10 20 30 125 75 100 20 50 10 40 13-/22-MXQ6(L) 13-/22-MXQ8(L) 13-/22-MXQ12(L) 13-/22-MXQ16(L) 13-/22-MXQ20(L) 13-/22-MXQ25(L) 6 4.5 5.5 5.5 13.5 5.5 13.5 1 1 1 9 9 7.5 5 12 32 8 31 8 16 3.5 3.5 7.5 11.5 26.5 27.5 11.5 6 40.5 14.5 40.5 14.5 21.5 24.5 21.5 20 10 10 17 17 36 36 16.5 26 16 16 16 22 29 47 47 7 51.5 20.5 33.5 51.5 20.5 26.5 30.5 20.5 39 29 19 29 27 35 67 70 75 19 8 71.5
Lead wire length symbols: Auto switches marked with are made-to-order specification. 0.5 m Nil (Example) A93 3 m L (Example) A93L 5 m Z (Example) F9NWZ Auto switches other than those listed above are also available. Refer to page 11-8-9 for details.
Select the bore size and type of magnet holding force (types H, L) from Lo and Fn based on data K A .
Follow the appropriate procedure (R or L) shown in Table 2.
However, please contact SMC for water-resistant products of 20 and 25. 2 1 m type lead wire is only applicable to D-A93. Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ None N (Example) H7CN Solid state auto switches marked with are produced upon receipt of order.
A AA C J L L J K (4 locations) Flat washer With 4 pcs.
Lead wire*(m) Rail mounting 20 to 63 Load voltage Direct mounting 32 to 63 Indicator Special function Wiring (output) Electrical entry Applicable load (N) Style 0.5 () 3 (L) 5 (Z) DC AC Perpendicular In-line Perpendicular In-line 3 wire (NPN Equiv.) A76H A96V A96 IC 5V A72 A73 A72H A73H 200V Yes Yes No No Yes Yes Grommet Reed switch 12V 100V A93V A90V A93 A90 Option Part No.
Magnet: D (Built-in), Rod Type: Standard, Mounting: B [Through Hole (Standard)], Bore Size: 20mm, Stroke: 30mm, Body Option: M (Rod End Male Thread), Auto Switch Groove: Z (Auto Switch Mounting Grooves), Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal