(n = 2, 4, 6, 8) (n = 2, 4, 6, 8) D-A5/A6 D-A59W D-F5/J5 D-F5W D-J59W D-F5BAL D-F59F 2 pcs. (Different surfaces, Same surface), 1 pc. 125 25 135 150 25 + 55 (n2) 2 125 + 55 (n4) 2 135 + 55 (n4) 2 150 + 55 (n4) 2 n pcs. (Same surface) (n = 2, 4, 6, 8) (n = 4, 8, 12, 16) (n = 4, 8, 12, 16) (n = 4, 8, 12, 16) 2 pcs.
Material: Carbon steel 20 Series MU Auto Switch Proper Mounting Position (Detection at stroke end) and Mounting Height D-M9 D-M9W D-M9AL D-A9 D-M9V D-M9WV D-M9AVL D-A9V B B A A Hs Hv D-M9 D-M9W D-M9AL D-M9V D-M9WV D-M9AVL D-A9 D-M9V D-M9WV D-M9AVL Size A B A B Hs Hv A B A B Hs Hv 25 5 5 5 5 7.5 27.5 1 1 1 1 32 5 5 5 5 14.5 30 1 1 1 1 40 5.5 5.5 5.5 5.5 16.5 37 1.5 1.5 1.5 1.5 50 7
Auto Switch Proper Mounting Position (at Stroke End Detection) Center of magnet A D-M9m, D-M9mV D-M9mW, D-M9mWV (mm) D-A9, D-A9mV (mm) A Operating range Bore size 16 25 A Operating range Bore size 16 25 30 9 34 4.5 30 9 34 4.5 Note) Only adjust the setting position after confirming the auto switch is properly activated.
model D-F5 D-J5 D-F5W D-J59W D-F5BAL D-F59F D-F5NTL D-A5 D-A6 D-A3 D-A44 D-G39 D-K39 D-F5W D-J59W D-F5BAL D-F5 D-J5 D-F59F D-A59W D-F5NTL Bore size (mm) Bore size (mm) A B A B A B A B Hs Hs Ht Hs Hs Ht 125 125 2 75.5 69.5 74.5 70 116 126 4.5 4.5 9.5 9.5 0 0 2 140 140 2 81 76.5 80 76.5 124 134 4.5 4.5 9.5 9.5 0 0 2 160 160 2 89 87.5 88 87.5 134.5 144.5 4.5 4.5 9.5 9.5 0 0 2 180 180 7.5 97.0
/40/50/63 D-X 20B A Data Solid State Switch D-Y59 , D-Y69 , D-Y7P(V) A B A B Reed Switch D-Z73, D-Z76, D-Z80 (mm) D-Y7BAL (mm) D-Y7NW(V), D-Y7PW(V), D-Y7BW(V) 63 50 40 32 25 Mounting position 40 32 25 Mounting position 63 50 40 32 25 Mounting position A A 229.5 184.5 139.5 278.5 229.5 184.5 139.5 323.5 A 323.5 278.5 229.5 184.5 139.5 B B 110.5 95.5 180.5 121.5 110.5 95.5 180.5 136.5 B 136.5
CY3RG25 CY3RG32 CY3RG40 16 Series CY3R Auto Switch Proper Mounting Position for Stroke End Detection Auto Switch Operation Range (Reference dimension) Bore size (mm) Auto switch model 15 20 25 32 40 D-A9 8 6 D-F9, D-F9W 5 4 D-Z7, Z80 9 9 11 A B D-Y59, Y7P D-Y7W 6 6 6 Switches cannot be mounted in some cases.
, D-F9WV D-M9 , D-F9W D-A9V D-F9V D-M9N B P D-F9BA No. of auto switches 15 20 25 10 10 5 2 10 15 20 25 5 5 1 Consult P/A for shorter stroke lengths than indicated in the table.
(mm) D-M9V D-M9WV D-M9A D-M9AV D-A9 D-A9V D-M9 D-M9V D-M9W D-M9WV D-M9A D-M9AV D-A90V D-A96V D-A93V Bore size (mm) D-A90 D-A96 D-A93 D-M9 D-M9W Bore size (mm) Mounting pattern q, w Mounting pattern e 32 32 20 22 35 20 10 15 25 12 5 10 Mounting of Auto Switch As shown below, there are 3 ways to mount the auto switch according to 3 types of electrical entries.
GR-S-010 (10 g) GR-S-020 (20 g) Guide unit GR-L-005 (5 g) GR-L-010 (10 g) Cylinder unit High carbon chrome bearing steel Stainless steel NBR NBR NBR 25 Series MXQR Auto Switch Proper Mounting Position (Detection at Stroke End) Solid State Auto Switch: D-M9B, D-M9N, D-M9P, D-M9BW, D-M9NW, D-M9PW Stroke B Stroke E A Model 10 20 30 125 75 100 40 50 150 10 20 30 125 75 100 40 50 150 MXQR6 17.5
Yes Reed circuit Grommet 100V A93V*2 A93 2-wire 24V 12V Relay, PLC No 100V or less A90V A90 IC circuit *1 Although it is possible to mount water resistant type auto switches, note that the rotary actuator itself is not of water resistant construction. *2 1m type lead wire is only applicable to D-A93.
Reed Auto Switch D-A90(V), D-A93(V), D-A96(V) Reed Auto Switch D-A90(V), D-A93(V), D-A96(V) (mm) Tightening Torque Stroke (mm) 20 45 25 45 25 51 31 Stroke (mm) 10 34.5 35.5 14.5 15.5 Model Model Tightening Torque of Auto Switch Mounting Screw (Nm) 25 50.5 30.5 30 59 39 10 35 15 35 15 15 40.5 20.5 A B A B A B A B A B C D Auto switch model Tightening torque MXP8 D-A9(V) D-M9(V) D-M9W(
Minimum Stroke for Auto Switch Mounting (mm) 12 16 20 25 32 40 50 63 80 100 Auto switch model No. of auto switches mounted 1 pc. 10 5 D-A9 2 pcs. 15 10 D-A9V D-M9V 1 pc. 5 2 pcs. 10 1 pc. 15 10 5 D-M9 2 pcs. 15 10 1 pc. 15 10 D-M9W 2 pcs. 15 10 1 pc. 10 D-M9WV 2 pcs. 10 D-Z7 D-Z80 1 pc. 10 5 2 pcs. 15 10 D-Y59 D-Y7P 1 pc. 5 10 2 pcs. 15 10 D-Y69 D-Y7PV 1 pc. 5 2 pcs. 5 D-Y7W D-Y7WV 1 pc.
Bore size 12 16 20 25 12 mm 16 mm 20 mm 25 mm Cylinder stroke (mm) Refer to "Standard Stroke" on page 10-4-3. Bumper/Rod end thread Rubber bumper & Rod end female thread C Rubber bumper & Rod end male thread CM Action D Double acting Applicable Auto Switch/Refer to page 10-20-1 for further information on auto switches.
Bore size 12 16 20 25 12 mm 16 mm 20 mm 25 mm Cylinder stroke (mm) Refer to "Standard Stroke" on page 10-4-3. Bumper/Rod end thread Rubber bumper & Rod end female thread C Rubber bumper & Rod end male thread CM Action D Double acting Applicable Auto Switch/Refer to page 10-20-1 for further information on auto switches.
(n = 4, 8, 12, 16) (n = 4, 8, 12, 16) D-A5/A6 D-A59W D-F5/J5 D-F5W D-J59W D-F5BAL D-F59F With 2 pcs. (Different surfaces, Same surface), With 1 pc. 135 125 25 135 + 55(n 4) 2 25 + 55(n 2) 2 (n = 4, 8, 12, 16) 125 + 55(n 4) 2 With n pcs. (Same surface) (n = 4, 8, 12, 16) (n = 2, 4, 6, 8) With 2 pcs.
Applicable model: D-A73, A73H, A73C, C73, C73C, E73A, Z73 D-R73, R73C, 97, 93A, A93, A93V D-A33, A34, A33A, A34A, A44, A44A D-A53, A54, B53, B54 2) When using a 2-color indicator type auto switch (D-A79W, A59W and B59W), the auto switch will constantly remain ON if the connections are reversed.
B Reverse the mounting direction A Reed switch D-A90(V), D-A93(V), D-A96(A) mm Auto switch mounting Switch operating range Stroke (mm) 20 45 25 51 31 Type 25 50.5 30.5 30 59 39 10 35 15 40.5 20.5 Caution A B A B A B MXP10 Tool for auto switch mounting MXP12 5 Use the screwdriver with grip diameter 5 to 6 mm when set screw (attached to auto switch) is set.
Switch Mounting Applicable auto switch model (mm) No. of auto switches mounted D-A9 D-A9V D-M9 D-M9V D-M9W D-M9WV 1 pc. 5 5 5 2 pcs. 10 5 10 MXH Auto Switch Proper Mounting Position (Detection at Stroke End) and Its Mounting Height MXU D-A9 D-M9 D-M9W MXS A 22 (24.5) MXQ MXF MXW MXJ W B ( ): denotes the values of D-A93.
MY1CW16/20 MY1MW16/20 B A Reed Switch Solid State Switch D-A90(V), D-A93(V), D-A96(V) (mm) D-M9N(V), D-M9P(V), D-M9B(V) D-F9NW(V), D-F9PW(V), D-F9BW(V) 16 20 Mounting position Mounting position 16 20 A A B B Operating range Note) Operating range Note) Solid State Switch Reed Switch 24 Series MY1W Mounting of Auto Switch & Installation of Lead Wire Cover (50, 63) Caution Be sure to install
Auto Switch Proper Mounting Position (Detection at Stroke End) D-A93 12 16 to 25 A B W A B W D-M9B/M9N 12 16 to 25 A B W A B W B D-A93 B D-M9B/M9N/M9P Bore size (mm) A 11.5 W 4 A 15.5 W 5.5 12 16 20 25 0.5 4.5 12 0 4.5 16 4 6 16 3.5 1 20 7.5 2.5 17 5.5 -1 21 9.5 0.5 Specific Product Precautions Be sure to read this before handling. Mounting Caution 1.