SMC Corporation of America
Elite Part Number Search
Search Results "CDLA2D100-700-D"

3 Port Solenoid Valve Rubber Seal Series SYJ300/500/700 SY SYJ Low power consumption: 0.5W (Without light) (Current draw: 21mA at 24V DC) VK VZ Completely interchangeable with the previous series VJ300/500/700 and VZ300/500. VT Pilot exhaust VT VP Mounts on the same subplates and manifolds as the VJ300/500/700 and the VZ300/500.

H H H H G E G X E X Note ) E X RG RT RS B 600 740 C R310 R445 D 296 302 E 620 890 F 93 129 G 60 87 B 680 790 C R390 R495 D 296 302 E 780 990 F 93 129 G 60 87 B 640 740 C R350 R440 D 296 307 E 634 800 F 93 129 H 10 15 A 700 1000 A 700 880 A 700 880 15 32 15 32 15 32 I 6 7 X 740 1064 Y Note 2) I 6 7 X 660 816 Y Note 2) X 700 880 Y Note 2) H 10 15 H 10 15 I 6 7 15 32 15 32 15 32 558 to 573

Data (A) Volume of Cylinder/Capacity of Converter 160 140 180 125 300 250 800 700 600 200 Selection Step 100 10,000 8,000 6,000 5,000 4,000 500 400 Step (1) Select the bore size of air-hydro cylinder 80 300 First of all, select a bore size from data (D) .

64 (102) 3H9 (+0.025 0 ) depth 3 4 x M5 x 0.8 thread depth 8.5 38 50 3.5 3H9 (+0.025 0 ) depth 3 A (Table traveling distance) L 51 (52) 10 10 58 38 48 38.5 (48) 26 24 n x 4.5 Vacuum port Rc1/8 48 120 F D x 120 (= E) B Dimensions [mm] Dimensions [mm] Model L A B n D E F 11-LEFG25-S-50 180 57 160 4 20 11-LEFG25-S-100 230 107 210 Model L A B n D E F 11-LEFG25-S-450 580 457 560 10 4 480 35

Magnet: Built-in, Mounting: Double Clevis, Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 100mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: J59--Solid State, Gen. Purpose, 2 Wire, Lead Wire or Prewied Connector: -, Number: -

Magnet: Built-in, Mounting: Double Clevis, Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 300mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: J59W--Solid State, 2-color Indication, 2 Wire, Lead Wire or Prewied Connector: 3m, Number: -

Magnet: Built-in, Mounting: Double Clevis, Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 500mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: B59W--Reed, DC Volt >5 <24, 2-color Indication, Lead Wire or Prewied Connector: 3m, Number: -

Magnet: Built-in, Mounting: Double Clevis, Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 200mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: G59--Solid State, Gen. Purpose,3 Wire NPN, Lead Wire or Prewied Connector: 3m, Number: -

Magnet: D (Built-in), Mounting: D (Double Clevis), Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 400mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: D (Spring/Air Pressure Lock), Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewied Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector)

Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 550, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification

Magnet: Built-in, Mounting: Double Clevis, Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 400mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewied Connector: 0.5m Cord Length, M8-3 Pin Connector, Number: -

Magnet: Built-in, Mounting: Double Clevis, Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 150mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: J59--Solid State, Gen. Purpose, 2 Wire, Lead Wire or Prewied Connector: -, Number: -

Magnet: Built-in, Mounting: Double Clevis, Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 250mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: A54--Reed, DC Volt >5<24, AC Volt <200, LED, Lead Wire or Prewied Connector: 3m, Number: -

Magnet: Built-in, Mounting: Double Clevis, Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 400mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: K59W--Solid State, 2-color Indication, 2 Wire, Lead Wire or Prewied Connector: -, Number: -

Magnet: Built-in, Mounting: Double Clevis, Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 400mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: K59W--Solid State, 2-color Indication, 2 Wire, Lead Wire or Prewied Connector: 0.5m Cord Length, M12-4 Pin Connector, Number: -

Magnet: Built-in, Mounting: Double Clevis, Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 450mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: A54--Reed, DC Volt >5<24, AC Volt <200, LED, Lead Wire or Prewied Connector: 5m, Number: -

Magnet: Built-in, Mounting: Double Clevis, Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 500mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: A54--Reed, DC Volt >5<24, AC Volt <200, LED, Lead Wire or Prewied Connector: 3m, Number: -